Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Enhancing the accuracy of low-cost thermocouple devices through deep-wavelet neural network calibration

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 3 (2024)

DOI
10.11591/ijece.v14i3.pp2625-2633
ISSN
2722-2578, 2088-8708
Terbit
2024-06-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Data collection using thermocouple sensors in low-cost data acquisition is prone to noise interference, which could reduce the data quality. Noise sources such as cold junction compensators, electromagnetic interference, and Johnson noise can significantly affect the reliability and accuracy of conventional measurements. This study aims to improve the quality of thermocouple sensor readings on low-cost data acquisition using calibration method based on deep learning and the denoising process using a wavelet transform. This taken approach successfully increase the accuracy value of 97.67% with a mean absolute error (MAE) of 0.2. The precision also increases of 262.7% as indicated by the result of signal-to-noise ratio (SNR) with a value of 105.29 dB. Comparative analysis was carried out against National Instruments® device and it was found that deep-wavelet method had a lower and higher of MAE and SNRdB values of 16.67% and 0.8% respectively. This study shows that the denoising-calibration method with deep-wavelet can improve the accuracy and reliability of data from low-cost thermocouple devices.

Jaringan kolaborasi para penulis

13 penulis · 30 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Pembangunan Nasional Veteran Jakarta
  • Politeknik Negeri Bali
  • Kementerian Energi dan Sumber Daya Mineral
  • Muhammadiyah University of Surakarta
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Cahyo Setyo WibowoKementerian Energi dan Sumber Daya Mineral1
Imansyah Ibnu HakimAfiliasi tidak diketahui1
Bambang SuryawanAfiliasi tidak diketahui1
I Made Kartika DAfiliasi tidak diketahui1
I Made RastaAfiliasi tidak diketahui1
I Gusti Ketut PujaAfiliasi tidak diketahui1
Ngafwan NgafwanMuhammadiyah University of Surakarta1
I Nyoman SuamirAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Enhancing the accuracy of low-cost thermocouple devices through deep-wavelet neural network calibration</dc:title><dc:creator>Julian, James</dc:creator><dc:creator>Wahyuni, Fitri</dc:creator><dc:creator>Dewantara, Annastya Bagas</dc:creator><dc:creator>Winarta, Adi</dc:creator><dc:creator>Putra, Nandy</dc:creator><dc:description>&lt;jats:p&gt;Data collection using thermocouple sensors in low-cost data acquisition is prone to noise interference, which could reduce the data quality. Noise sources such as cold junction compensators, electromagnetic interference, and Johnson noise can significantly affect the reliability and accuracy of conventional measurements. This study aims to improve the quality of thermocouple sensor readings on low-cost data acquisition using calibration method based on deep learning and the denoising process using a wavelet transform. This taken approach successfully increase the accuracy value of 97.67% with a mean absolute error (MAE) of 0.2. The precision also increases of 262.7% as indicated by the result of signal-to-noise ratio (SNR) with a value of 105.29 dB. Comparative analysis was carried out against National Instruments® device and it was found that deep-wavelet method had a lower and higher of MAE and SNRdB values of 16.67% and 0.8% respectively. This study shows that the denoising-calibration method with deep-wavelet can improve the accuracy and reliability of data from low-cost thermocouple devices.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i3.pp2625-2633</dc:identifier><dc:identifier>10.11591/ijece.v14i3.pp2625-2633</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 3 (2024); 2625</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/33936/17405</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>