Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Enhancing of single-stage grid-connected photovoltaic system using fuzzy logic controller

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 3 (2024)

DOI
10.11591/ijece.v14i3.pp2400-2412
ISSN
2722-2578, 2088-8708
Published
2024-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The power generated by photovoltaic (PV) systems is influenced by environmental factors. This variability hampers the control and utilization of solar cells' peak output. In this study, a single-stage grid-connected PV system is designed to enhance power quality. Our approach employs fuzzy logic in the direct power control (DPC) of a three-phase voltage source inverter (VSI), enabling seamless integration of the PV connected to the grid. Additionally, a fuzzy logic-based maximum power point tracking (MPPT) controller is adopted, which outperforms traditional methods like incremental conductance (INC) in enhancing solar cell efficiency and minimizing the response time. Moreover, the inverter's real-time active and reactive power is directly managed to achieve a unity power factor (UPF). The system's performance is assessed through MATLAB/Simulink implementation, showing marked improvement over conventional methods, particularly in steady-state and varying weather conditions. For solar irradiances of 500 and 1,000 W/m 2, the results show that the proposed method reduces the total harmonic distortion (THD) of the injected current to the grid by approximately 46% and 38% compared to conventional methods, respectively. Furthermore, we compare the simulation results with IEEE standards to evaluate the system's grid compatibility.

Collaboration network of the authors

3 authors · 3 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Al-Azhar University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Enhancing of single-stage grid-connected photovoltaic system using fuzzy logic controller</dc:title><dc:creator>Haseeb, Mahmoud</dc:creator><dc:creator>Hassan Ibrahim Mansour, Ali</dc:creator><dc:creator>Othman, El-Said A.</dc:creator><dc:description>&lt;jats:p&gt;The power generated by photovoltaic (PV) systems is influenced by environmental factors. This variability hampers the control and utilization of solar cells' peak output. In this study, a single-stage grid-connected PV system is designed to enhance power quality. Our approach employs fuzzy logic in the direct power control (DPC) of a three-phase voltage source inverter (VSI), enabling seamless integration of the PV connected to the grid. Additionally, a fuzzy logic-based maximum power point tracking (MPPT) controller is adopted, which outperforms traditional methods like incremental conductance (INC) in enhancing solar cell efficiency and minimizing the response time. Moreover, the inverter's real-time active and reactive power is directly managed to achieve a unity power factor (UPF). The system's performance is assessed through MATLAB/Simulink implementation, showing marked improvement over conventional methods, particularly in steady-state and varying weather conditions. For solar irradiances of 500 and 1,000 W/m&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;, the results show that the proposed method reduces the total harmonic distortion (THD) of the injected current to the grid by approximately 46% and 38% compared to conventional methods, respectively. Furthermore, we compare the simulation results with IEEE standards to evaluate the system's grid compatibility.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i3.pp2400-2412</dc:identifier><dc:identifier>10.11591/ijece.v14i3.pp2400-2412</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 3 (2024); 2400</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/34283/17335</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>