Abstract

One of the most popular electric motors used today is the 3-phase induction motor, which has a sturdy design, is less expensive, and is simple to use. Improvements to the materials used in the rotor or stator of induction motors, raising the number of motor phases, and employing a 3-phase induction motor for 1-phase power are just a few of the ways the motor is now being developed to perform better. These studies are all pricey, though. The goal of this study is to determine how to enhance the motor's performance at a reasonable cost. The suggested remedy was to create a 3-phase induction motor winding with a 1-layer design that resembled a symmetrical 6-phase winding. The primary study topics were the motor's rotor speed, mechanical torque, efficiency, and winding current when it was powered by a three-phase power source. The results of the study show that, although consuming less winding current, the 3-phase induction motor with a new winding design outperforms a traditional 3-phase induction motor in terms of rotor speed, mechanical torque, and efficiency.

Collaboration network of the authors

15 authors · 56 co-authorship links · 6 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Institut Teknologi Padang
  • Andalas University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Anggun AnugrahInstitut Teknologi Padang5
Abdul RajabAndalas University3
Chitra YuanisaInstitut Teknologi Padang3
Rizki Oktrinanda ElyasInstitut Teknologi Padang3
Andi M. Nur PutraInstitut Teknologi Padang3
Sitti AmaliaInstitut Teknologi Padang3
Dasman DasmanInstitut Teknologi Padang3
Antonov BachtiarInstitut Teknologi Padang3
Hamdi AzharInstitut Teknologi Padang3

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>A winding design for improving 3-phase induction motor performance</dc:title><dc:creator>Anthony, Zuriman</dc:creator><dc:creator>Bandri, Sepannur</dc:creator><dc:creator>Erhaneli, Erhaneli</dc:creator><dc:creator>Warmi, Yusreni</dc:creator><dc:creator>Zulkarnaini, Zulkarnaini</dc:creator><dc:creator>Dewi Rachman, Arfita Yuana</dc:creator><dc:description>&lt;jats:p&gt;One of the most popular electric motors used today is the 3-phase induction motor, which has a sturdy design, is less expensive, and is simple to use. Improvements to the materials used in the rotor or stator of induction motors, raising the number of motor phases, and employing a 3-phase induction motor for 1-phase power are just a few of the ways the motor is now being developed to perform better. These studies are all pricey, though. The goal of this study is to determine how to enhance the motor's performance at a reasonable cost. The suggested remedy was to create a 3-phase induction motor winding with a 1-layer design that resembled a symmetrical 6-phase winding. The primary study topics were the motor's rotor speed, mechanical torque, efficiency, and winding current when it was powered by a three-phase power source. The results of the study show that, although consuming less winding current, the 3-phase induction motor with a new winding design outperforms a traditional 3-phase induction motor in terms of rotor speed, mechanical torque, and efficiency.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i3.pp2413-2421</dc:identifier><dc:identifier>10.11591/ijece.v14i3.pp2413-2421</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 3 (2024); 2413</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/34724/17336</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>