Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Voltage and frequency control of microgrid in presence of micro-turbine interfaced to matrix converter

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 3 (2024)

DOI
10.11591/ijece.v14i3.pp2466-2479
ISSN
2722-2578, 2088-8708
Published
2024-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The active and reactive load changes have a significant impact on voltage and frequency. In this paper, in order to stabilize the microgrid (MG) against load variations in islanding mode, the active and reactive power of all distributed generators (DGs), including energy storage (battery), diesel generator, and micro-turbine, are controlled. The micro-turbine generator is connected to MG through a three-phase to three-phase matrix converter, and the droop control method is applied for controlling the voltage and frequency of MG. In addition, a method is introduced for voltage and frequency control of micro-turbines in the transition state from grid-connected mode to islanding mode. A novel switching strategy of the matrix converter is used for converting the high-frequency output voltage of the micro-turbine to the grid-side frequency of the utility system. Moreover, using the switching strategy, the low-order harmonics in the output current and voltage are not produced, and consequently, the size of the output filter would be reduced. In fact, the suggested control strategy is load-independent and has no frequency conversion restrictions. The proposed approach for voltage and frequency regulation demonstrates exceptional performance and favorable response across various load alteration scenarios. The suggested strategy is examined in several scenarios in the MG test systems, and the simulation results are addressed.

Collaboration network of the authors

40 authors · 94 co-authorship links · 52 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknikal Malaysia Melaka
  • University of Technology Malaysia
  • Islamic Azad University, Tehran
  • Universitas Ahmad Dahlan
  • Damghan University
  • Azarbaijan Shahid Madani University
  • Sultan Agung Islamic University
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nik Rumzi Nik IdrisUniversity of Technology Malaysia9
Mohammad JannatiUniversity of Technology Malaysia9
Mohd Hatta JopriUniversiti Teknikal Malaysia Melaka8
Mohd Junaidi Abdul AzizUniversity of Technology Malaysia7
Mustafa ManapUniversiti Teknikal Malaysia Melaka7
Awang JusohUniversity of Technology Malaysia7
Abdul Rahim AbdullahUniversiti Teknikal Malaysia Melaka6
M. Rahimi YusoffUniversiti Teknikal Malaysia Melaka4
Muhammad AdoUniversity of Technology Malaysia4
Lina HandayaniUniversitas Ahmad Dahlan3
Imam Much Ibnu SubrotoSultan Agung Islamic University3
Shahreen binti KasimTun Hussein Onn University of Malaysia3
Mahmoud ZadehbagheriIslamic Azad University, Tehran3
Mohammad Javad KianiIslamic Azad University, Tehran3
Vahdat NazerianUniversity of Mazandaran3
Auzani JidinUniversiti Teknikal Malaysia Melaka2
M. GhanbariAffiliation unknown2
Munawar Agus RiyadiDiponegoro University2
Deris StiawanSriwijaya University2
M. Najafi KhoshrodiAffiliation unknown2
A.S. HussinUniversiti Teknikal Malaysia Melaka2
Mohd Ruddin Ab GhaniUniversiti Teknikal Malaysia Melaka2
Mehdi DadkhahIslamic Azad University, Tehran2
Shahaboddin ShamshirbandUniversity of Malaya2
Ahmad Saudi SamosirLampung University2
Chibuike Peter OhanuUniversity of Nigeria2
Aiman Zakwan JidinUniversiti Teknikal Malaysia Melaka1
Rozana AlikUniversity of Technology Malaysia1
M.F. HabbanUniversiti Teknikal Malaysia Melaka1
Muhammad Firdaus Abd RazakUniversity of Technology Malaysia1
Mohamad Hamka Bin SaifulUniversity of Technology Malaysia1
Abdul Rashid HusainUniversity of Technology Malaysia1
Sahazati Md RozaliUniversiti Teknikal Malaysia Melaka1
Muhammad Nizam KamarudinUniversiti Teknikal Malaysia Melaka1
Abdulhamid Usman MutawakkilUniversity of Technology Malaysia1
Moloud AbdarDamghan University1
Sharareh Rostam Niakan KalhoriDamghan University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Voltage and frequency control of microgrid in presence of micro-turbine interfaced to matrix converter</dc:title><dc:creator>Toupchi Khosroshahi, Mahdi</dc:creator><dc:creator>Ajami, Ali</dc:creator><dc:creator>Sutikno, Tole</dc:creator><dc:description>&lt;jats:p&gt;The active and reactive load changes have a significant impact on voltage and frequency. In this paper, in order to stabilize the microgrid (MG) against load variations in islanding mode, the active and reactive power of all distributed generators (DGs), including energy storage (battery), diesel generator, and micro-turbine, are controlled. The micro-turbine generator is connected to MG through a three-phase to three-phase matrix converter, and the droop control method is applied for controlling the voltage and frequency of MG. In addition, a method is introduced for voltage and frequency control of micro-turbines in the transition state from grid-connected mode to islanding mode. A novel switching strategy of the matrix converter is used for converting the high-frequency output voltage of the micro-turbine to the grid-side frequency of the utility system. Moreover, using the switching strategy, the low-order harmonics in the output current and voltage are not produced, and consequently, the size of the output filter would be reduced. In fact, the suggested control strategy is load-independent and has no frequency conversion restrictions. The proposed approach for voltage and frequency regulation demonstrates exceptional performance and favorable response across various load alteration scenarios. The suggested strategy is examined in several scenarios in the MG test systems, and the simulation results are addressed.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i3.pp2466-2479</dc:identifier><dc:identifier>10.11591/ijece.v14i3.pp2466-2479</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 3 (2024); 2466</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/35006/17340</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>