Abstract

The development of fault detection methods in wind turbine (WT), especially for single fault detection, is continuously increasing. However, the rapid growth of fault detection in WT leads to another challenge where multiple faults can occur. The single fault detection method in WT is no longer reliable, especially when multiple faults occur simultaneously. Therefore, multiple faults detection in doubly-fed induction generators (DFIG) WT was proposed using an artificial neural networks (ANN) model. These multiple faults include internal and external stator faults happening simultaneously. Internal stator faults cover inter-turn short circuit faults and open circuit faults, while external stator faults cover loss of excitation and external short circuit faults. The performance of the developed multiple faults detection model was measured using accuracy and the root mean square error (RMSE) value. The results show that the developed model performs well with high accuracy and a low RMSE value. Thus, the developed model can accurately detect the coexistence of multiple faults in DFIG WT.

Collaboration network of the authors

11 authors · 24 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Malaysia Perlis
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
N. S. B. JamiliUniversiti Malaysia Perlis1
Mohd Rafi AdzmanUniversiti Malaysia Perlis1
Siti Rafidah Abdul RahimUniversiti Malaysia Perlis1
Muzamir IsaUniversiti Malaysia Perlis1
Hafizuddin HanafiUniversiti Malaysia Perlis1
Nurul Fatin NadhirahUniversiti Malaysia Perlis1
Hana Abdull HalimUniversiti Malaysia Perlis1
Nurhakimah Mohd MukhtarUniversiti Malaysia Perlis1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Multiple faults detection in doubly-fed induction generator wind turbine using artificial neural network</dc:title><dc:creator>Fadzail, Noor Fazliana</dc:creator><dc:creator>Zali, Samila Mat</dc:creator><dc:creator>Mid, Ernie Che</dc:creator><dc:description>&lt;jats:p&gt;The development of fault detection methods in wind turbine (WT), especially for single fault detection, is continuously increasing. However, the rapid growth of fault detection in WT leads to another challenge where multiple faults can occur. The single fault detection method in WT is no longer reliable, especially when multiple faults occur simultaneously. Therefore, multiple faults detection in doubly-fed induction generators (DFIG) WT was proposed using an artificial neural networks (ANN) model. These multiple faults include internal and external stator faults happening simultaneously. Internal stator faults cover inter-turn short circuit faults and open circuit faults, while external stator faults cover loss of excitation and external short circuit faults. The performance of the developed multiple faults detection model was measured using accuracy and the root mean square error (RMSE) value. The results show that the developed model performs well with high accuracy and a low RMSE value. Thus, the developed model can accurately detect the coexistence of multiple faults in DFIG WT.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i3.pp3342-3349</dc:identifier><dc:identifier>10.11591/ijece.v14i3.pp3342-3349</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 3 (2024); 3342</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/35301/17439</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>