Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Transient response of a megawatt-scale solar photovoltaic in an electric distribution utility

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 4 (2024)

DOI
10.11591/ijece.v14i4.pp3739-3754
ISSN
2722-2578, 2088-8708
Terbit
2024-08-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

There is an increasing trend among customers of an electrical distribution utility to adopt grid-tied solar photovoltaic systems. This shift offers multiple benefits to consumers, including lower monthly electricity bills and a contribution to the development of green energy. For the electrical distribution utility, various impacts may arise due to varying levels of solar energy penetration. This study investigates the effects of integrating varying levels of solar photovoltaic penetration into the commercial consumer network of Cagayan de Oro Electric Power and Light Company (CEPALCO) in the Philippines. Utilizing PowerWorld simulator, the research evaluates 11 different scenarios with solar penetration levels adjusted according to the percentage of load demand. Key findings include alterations in solar megavolt ampere of reactive power output, bus voltage levels, transformer power loading, and transmission line ampacity, with frequency levels remaining stable across scenarios. The optimal solar penetration level was identified at 70%, balancing the benefits of solar energy integration with the need to maintain grid stability and operational limits. This optimal level ensures the effective utilization of renewable energy sources without compromising the performance of CEPALCO’s electrical infrastructure. The research concludes with recommendations for maintaining grid stability and operational limits at the optimal solar penetration limits.

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Science and Technology of Southern Philippines
  • Caraga State University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Transient response of a megawatt-scale solar photovoltaic in an electric distribution utility</dc:title><dc:creator>Judith, Paolo Justine</dc:creator><dc:creator>Dellosa, Jeffrey T.</dc:creator><dc:description>&lt;jats:p&gt;There is an increasing trend among customers of an electrical distribution utility to adopt grid-tied solar photovoltaic systems. This shift offers multiple benefits to consumers, including lower monthly electricity bills and a contribution to the development of green energy. For the electrical distribution utility, various impacts may arise due to varying levels of solar energy penetration. This study investigates the effects of integrating varying levels of solar photovoltaic penetration into the commercial consumer network of Cagayan de Oro Electric Power and Light Company (CEPALCO) in the Philippines. Utilizing PowerWorld simulator, the research evaluates 11 different scenarios with solar penetration levels adjusted according to the percentage of load demand. Key findings include alterations in solar megavolt ampere of reactive power output, bus voltage levels, transformer power loading, and transmission line ampacity, with frequency levels remaining stable across scenarios. The optimal solar penetration level was identified at 70%, balancing the benefits of solar energy integration with the need to maintain grid stability and operational limits. This optimal level ensures the effective utilization of renewable energy sources without compromising the performance of CEPALCO’s electrical infrastructure. The research concludes with recommendations for maintaining grid stability and operational limits at the optimal solar penetration limits.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i4.pp3739-3754</dc:identifier><dc:identifier>10.11591/ijece.v14i4.pp3739-3754</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 4 (2024); 3739</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/35291/17494</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>