An improved rule-based control of battery energy storage for hourly power dispatching of photovoltaic sources

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 4 (2024)

DOI
10.11591/ijece.v14i4.pp3783-3791
ISSN
2722-2578, 2088-8708
Published
2024-08-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This paper presents an improved rule-based control scheme for battery energy storage (BES) system with the goal of minimising the fluctuation output from photovoltaic (PV) sources while ensuring the operational constraints of BES are regulated at the specified ranges for safety purposes. The control scheme is formulated in accordance with the intended operational limitations of the BES, including charge/discharge current limits and state-of-charge (SOC). The simulation studies were carried out using MATLAB/Simulink to evaluate the effectiveness of an improved rule-based control scheme on the 1.2 MW PV system data acquired from a location in Malaysia. Furthermore, a comparative study on the effectiveness of an improved rule-based control scheme compared with the conventional rule-based control scheme has been carried out. The simulation results show that an improved rule-based control scheme can effectively reduce the fluctuations in the output power of the PV sources and dispatch the output to the utility grid on an hourly basis with an efficiency of up to 94.47%. Finally, the comparison results on the effects of the BESS capacity also illustrate that an improved rule-based control scheme is more effective compared to the conventional rule-based control scheme in the previous study.

Collaboration network of the authors

3 authors · 3 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Malaysia Terengganu
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>An improved rule-based control of battery energy storage for hourly power dispatching of photovoltaic sources</dc:title><dc:creator>Jusoh, Mohd Afifi</dc:creator><dc:creator>Ibrahim, Mohd Zamri</dc:creator><dc:creator>Daud, Muhamad Zalani</dc:creator><dc:description>&lt;jats:p&gt;This paper presents an improved rule-based control scheme for battery energy storage (BES) system with the goal of minimising the fluctuation output from photovoltaic (PV) sources while ensuring the operational constraints of BES are regulated at the specified ranges for safety purposes. The control scheme is formulated in accordance with the intended operational limitations of the BES, including charge/discharge current limits and state-of-charge (SOC). The simulation studies were carried out using MATLAB/Simulink to evaluate the effectiveness of an improved rule-based control scheme on the 1.2 MW PV system data acquired from a location in Malaysia. Furthermore, a comparative study on the effectiveness of an improved rule-based control scheme compared with the conventional rule-based control scheme has been carried out. The simulation results show that an improved rule-based control scheme can effectively reduce the fluctuations in the output power of the PV sources and dispatch the output to the utility grid on an hourly basis with an efficiency of up to 94.47%. Finally, the comparison results on the effects of the BESS capacity also illustrate that an improved rule-based control scheme is more effective compared to the conventional rule-based control scheme in the previous study.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i4.pp3783-3791</dc:identifier><dc:identifier>10.11591/ijece.v14i4.pp3783-3791</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 4 (2024); 3783</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/33543/17612</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>