Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Artificial intelligence for early-stage detection of chronic kidney disease

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 4 (2024)

DOI
10.11591/ijece.v14i4.pp4775-4790
ISSN
2722-2578, 2088-8708
Published
2024-08-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Early-stage detection of chronic kidney disease (CKD) is crucial in research to enable timely intervention, enhance understanding of disease progression, reduce healthcare costs and support public health initiatives. The traditional approaches on early-stage chronic kidney disease detection often suffer from slow convergence and not integrate advanced technologies, impacting their effectiveness. Additionally, security and privacy concerns related to patient data are ineffectively addressed. To overcome these issues, this research incorporates novel optimized artificial intelligence-based approaches. The main aim is to enhance detection process through enhanced hybrid mud ring network (EHMRN), a novel detection technique combining light gradient boosting machine and MobileNet, involving extensive data collection, including a large dataset of 100,000 instances. The introduced network is optimized through the mud ring optimization to attain enhanced performance. Incorporating spark ensures secure cloud-based storage, enhancing privacy and compliance with healthcare data regulations. This approach represents a significant advancement in primary stage detection more effectively and promptly. The results show that the introduced approach outperforms traditional approaches in terms of accuracy (99.96%), F1-score (99.91%), precision (100%), specificity (99.98%), recall (100%) and execution time (0.09 s).

Collaboration network of the authors

2 authors · 1 co-authorship link

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • CMR University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Artificial intelligence for early-stage detection of chronic kidney disease</dc:title><dc:creator>B, Mamatha</dc:creator><dc:creator>Terdal, Sujatha P</dc:creator><dc:description>&lt;jats:p&gt;Early-stage detection of chronic kidney disease (CKD) is crucial in research to enable timely intervention, enhance understanding of disease progression, reduce healthcare costs and support public health initiatives. The traditional approaches on early-stage chronic kidney disease detection often suffer from slow convergence and not integrate advanced technologies, impacting their effectiveness. Additionally, security and privacy concerns related to patient data are ineffectively addressed. To overcome these issues, this research incorporates novel optimized artificial intelligence-based approaches. The main aim is to enhance detection process through enhanced hybrid mud ring network (EHMRN), a novel detection technique combining light gradient boosting machine and MobileNet, involving extensive data collection, including a large dataset of 100,000 instances. The introduced network is optimized through the mud ring optimization to attain enhanced performance. Incorporating spark ensures secure cloud-based storage, enhancing privacy and compliance with healthcare data regulations. This approach represents a significant advancement in primary stage detection more effectively and promptly. The results show that the introduced approach outperforms traditional approaches in terms of accuracy (99.96%), F1-score (99.91%), precision (100%), specificity (99.98%), recall (100%) and execution time (0.09 s).&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i4.pp4775-4790</dc:identifier><dc:identifier>10.11591/ijece.v14i4.pp4775-4790</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 4 (2024); 4775</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/35106/17596</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>