Abstract

The load losses of the transformers increase considerably with the presence of harmonic distortion in the currents. Its increase can be determined using an analytical method based on ANSI/IEEE Standard C57.110. On the other hand, when it comes to three-phase banks with transformers of different capacities, delta connections, or incomplete connections, the analytical method does not allow the losses to be accurately estimated, which is why digital simulation is necessary. This work presents an adjusted model to determine the load losses in a three-phase bank of three single-phase transformers with different connection schemes. The model allows for determining load and electrical losses and calculating total additional losses. It is also possible to decide on the load capacity of the bank's transformers, the power factor, and the efficiency with which they operate under these conditions.

Collaboration network of the authors

22 authors · 50 co-authorship links · 19 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universidad de la Costa
  • Universidad Técnica de Manabí
  • Universidad de Oriente
  • Universidad del Magdalena
  • Polytechnic José Antonio Echeverría
  • Universidad de Las Tunas
  • Universidad EAFIT
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Israel Francisco Benítez PinaUniversidad de Oriente2
María Rodríguez GámezUniversidad Técnica de Manabí2
Antonio Vázquez PérezUniversidad Técnica de Manabí2
Yelena Pérez ZamoraUniversidad de Oriente1
Eliana Noriega AngaritaUniversidad de la Costa1
Angel R. RicardoAffiliation unknown1
Guillermo González-YeroAffiliation unknown1
Mirelys Torres PérezUniversidad de Las Tunas1
Christian Manuel Moreno RochaUniversidad de la Costa1
Celene Milanés BatistaUniversidad de la Costa1
Willian Fernando Arguello RodríguezUniversidad de la Costa1
Arley Jesús Fontalvo BallesterosUniversidad de la Costa1
Genial Belvine Epeni TomboUniversidad Técnica de Manabí1
Guillermo Antonio Loor CastilloUniversidad Técnica de Manabí1
Etna Mercedes Bayona VelásquezUniversidad del Magdalena1
Ana Pirela-RíosUniversidad EAFIT1
Ever Marín-GiraldoUniversidad del Magdalena1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Simulation of losses in a three-phase bank of transformers in the presence of harmonic distortion</dc:title><dc:creator>Grau-Merconchin, Frank</dc:creator><dc:creator>Hernández Areu, Orestes</dc:creator><dc:creator>Nuñez Alvarez, José Ricardo</dc:creator><dc:creator>Montenegro-Romero, Michael</dc:creator><dc:creator>Quintero-Ospino, Oscar</dc:creator><dc:description>&lt;jats:p&gt;The load losses of the transformers increase considerably with the presence of harmonic distortion in the currents. Its increase can be determined using an analytical method based on ANSI/IEEE Standard C57.110. On the other hand, when it comes to three-phase banks with transformers of different capacities, delta connections, or incomplete connections, the analytical method does not allow the losses to be accurately estimated, which is why digital simulation is necessary. This work presents an adjusted model to determine the load losses in a three-phase bank of three single-phase transformers with different connection schemes. The model allows for determining load and electrical losses and calculating total additional losses. It is also possible to decide on the load capacity of the bank's transformers, the power factor, and the efficiency with which they operate under these conditions.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i5.pp4827-4837</dc:identifier><dc:identifier>10.11591/ijece.v14i5.pp4827-4837</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 5 (2024); 4827</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/35059/17623</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>