Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Rotor angle deviation regulator to enhance the rotor angle stability of synchronous generators

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 5 (2024)

DOI
10.11591/ijece.v14i5.pp4879-4887
ISSN
2722-2578, 2088-8708
Published
2024-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Occurrences of disturbance affect the rotor angle operation of a synchronous generator in the generation system of a power system. The disturbance will disrupt the synchronous generator's rotor oscillation and result in rotor angle instability, which will degrade the power system's performance. This paper aims to develop a Lyapunov-based rotor angle deviation regulator for the nonlinear swing equation of a synchronous generator. The proposed regulator is expected to assure asymptotic stability of the rotor angle and robustness to uncertainty. Backstepping and Lyapunov redesign techniques are employed in developing the regulator. To validate the effectiveness and robustness of the regulator, a simulation in MATLAB/Simulink is carried out. The simulation result shows that the asymptotic stability and robustness of the regulator are guaranteed regardless of the disturbance.

Collaboration network of the authors

13 authors · 30 co-authorship links · 19 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknologi MARA
  • Universiti Teknikal Malaysia Melaka
  • University of Technology Malaysia
  • Sidi Mohamed Ben Abdellah University
  • Universitas Ahmad Dahlan
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nabil El FezaziSidi Mohamed Ben Abdellah University4
Abdul Rashid HusainUniversity of Technology Malaysia2
Nofri Yenita DahlanUniversiti Teknologi MARA2
Muhammad Ihsan Aziz JafarUniversiti Teknologi MARA2
Athirah Batrisyia Kamal AriffinUniversiti Teknologi MARA2
Wan Noraishah Wan Abdul MunimUniversiti Teknologi MARA2
Tole SutiknoUniversitas Ahmad Dahlan1
Sahazati Md RozaliUniversiti Teknikal Malaysia Melaka1
Mohamad Noh AhmadUniversity of Technology Malaysia1
Zaharuddin MohamedUniversity of Technology Malaysia1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Rotor angle deviation regulator to enhance the rotor angle stability of synchronous generators</dc:title><dc:creator>Murad, Nor Syaza Farhana Mohamad</dc:creator><dc:creator>Kamarudin, Muhammad Nizam</dc:creator><dc:creator>Zakaria, Muhammad Iqbal</dc:creator><dc:description>&lt;jats:p&gt;Occurrences of disturbance affect the rotor angle operation of a synchronous generator in the generation system of a power system. The disturbance will disrupt the synchronous generator's rotor oscillation and result in rotor angle instability, which will degrade the power system's performance. This paper aims to develop a Lyapunov-based rotor angle deviation regulator for the nonlinear swing equation of a synchronous generator. The proposed regulator is expected to assure asymptotic stability of the rotor angle and robustness to uncertainty. Backstepping and Lyapunov redesign techniques are employed in developing the regulator. To validate the effectiveness and robustness of the regulator, a simulation in MATLAB/Simulink is carried out. The simulation result shows that the asymptotic stability and robustness of the regulator are guaranteed regardless of the disturbance.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i5.pp4879-4887</dc:identifier><dc:identifier>10.11591/ijece.v14i5.pp4879-4887</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 5 (2024); 4879</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/35156/17628</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>