Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Assessing power quality in individual circuits of industrial electrical system

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 5 (2024)

DOI
10.11591/ijece.v14i5.pp4888-4896
ISSN
2722-2578, 2088-8708
Published
2024-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This article evaluates energy quality in individual circuits within an industrial electrical system and its impact on common connection point parameters. The research is crucial due to rising challenges in power quality arising from increased nonlinear electrical loads in industrial processes. The study involves sequential steps, covering the industrial electrical system´s description, power quality parameters analysis, and issue identification. A comprehensive assessment was conducted on a 3,000 kVA, 13.8 kV/460 V point of common coupling (PCC) transformer, and 10 transformers (10 to 250 kVA) supplying individual circuits. Findings indicated load factors below 70% in all transformers and a power factor below 0.9 in eight. Issues like voltage variation, current imbalance, and harmonic distortion were identified in nine transformers supplying individual circuits, while the PCC exhibited no power quality problems. The research emphasizes the importance of including individual circuits in power quality assessments, as compliance with regulatory limits at the PCC may not guarantee the absence of power quality issues in individual circuits, affecting equipment lifespan and increasing energy losses.

Collaboration network of the authors

24 authors · 64 co-authorship links · 38 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universidad de la Costa
  • University of Cienfuegos
  • Universidad Autónoma de Occidente
  • Universidad Simón Bolívar
  • Universidad de Oriente
  • University of Coimbra
  • Universidad Nacional de Río Cuarto
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Julio Rafael Gómez SarduyUniversity of Cienfuegos7
Percy R. ViegoUniversity of Cienfuegos5
Hernán Hernández HerreraUniversidad Simón Bolívar2
Iván D. LópezUniversidad Autónoma de Occidente2
Fernando J. T. E. FerreiraUniversity of Coimbra2
Adrián Bolaño MartínezUniversidad de la Costa2
Isaac Jimenez NavarroUniversidad de la Costa2
Pablo D. DonoloUniversidad Nacional de Río Cuarto2
Percy Rafael Viego FelipeUniversity of Cienfuegos2
José Pedro Monteagudo YanesUniversity of Cienfuegos2
Vladimir SousaUniversidad de la Costa1
Mario S. QuintanaUniversity of Cienfuegos1
Hernán HernándezUniversidad Simón Bolívar1
José Ricardo Núñez ÁlvarezUniversidad de la Costa1
Yelena Pérez ZamoraUniversidad de Oriente1
Israel Francisco Benítez PinaUniversidad de Oriente1
Laura Collazo SolarAffiliation unknown1
Ángel Costa MontielAffiliation unknown1
Miriam Vilaragut LlanesAffiliation unknown1
Abel Curbelo ColinaAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Assessing power quality in individual circuits of industrial electrical system</dc:title><dc:creator>Angarita, Eliana Noriega</dc:creator><dc:creator>Santos, Vladimir Sousa</dc:creator><dc:creator>Donolo, Pablo Daniel</dc:creator><dc:creator>Quispe, Enrique Ciro</dc:creator><dc:description>&lt;jats:p&gt;This article evaluates energy quality in individual circuits within an industrial electrical system and its impact on common connection point parameters. The research is crucial due to rising challenges in power quality arising from increased nonlinear electrical loads in industrial processes. The study involves sequential steps, covering the industrial electrical system´s description, power quality parameters analysis, and issue identification. A comprehensive assessment was conducted on a 3,000 kVA, 13.8 kV/460 V point of common coupling (PCC) transformer, and 10 transformers (10 to 250 kVA) supplying individual circuits. Findings indicated load factors below 70% in all transformers and a power factor below 0.9 in eight. Issues like voltage variation, current imbalance, and harmonic distortion were identified in nine transformers supplying individual circuits, while the PCC exhibited no power quality problems. The research emphasizes the importance of including individual circuits in power quality assessments, as compliance with regulatory limits at the PCC may not guarantee the absence of power quality issues in individual circuits, affecting equipment lifespan and increasing energy losses.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i5.pp4888-4896</dc:identifier><dc:identifier>10.11591/ijece.v14i5.pp4888-4896</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 5 (2024); 4888</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/35699/17629</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>