Melola Discovery

← Melola Discovery

Jurnal

Simulasi Alat Photoplethysmograph (PPG)

Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro · Vol. 1 No. 2 (2017)

DOI
10.22373/crc.v1i2.2081
ISSN
2549-3701, 2549-3698
Terbit
2017-11-02
Penerbit
PTE FTK UIN Ar-Raniry
Bahasa
eng

Abstrak

Heart is a vital organ in the human body. The heart functions circulated the blood throughout the body. The volume of blood in a body organ will vary due to blood pumping by the heart. Photoplethysmograph (PPG) is a device that can detect changes in blood volume using optical sensors. The purpose of this research is to make Photoplethysmograph monitoring system online. That is a device to monitor blood volume changes and display the change graph. Fluctuations in blood volume changes are influenced by the rhythm of blood pumping by the heart. Each peak on the PPG signal is correlated with one heartbeat. Photoplethysmograph charts can be used to determine the condition and abnormalities of a person's heart. Photoplethysmograph system online is realized in the form of sensors, amplifiers, LPF, ADC, and microcontroller as a serial interface, wiz610wi module, and web applications as online PPG graph viewer. Sensors composed of red LED and photoresistor (LDR) are placed on the fingers. The rays emitted by the LEDs are received by the LDR. The signals received by the LDR vary according to the volume of blood changes. The sensor output signal is then amplified and filtered. Incoming filter output signal ADC, serial interface by AT89C2051 then by wiz610wi module transmitted for display and monitored. Obtained Devices and apps created have worked well. The signal shown is pretty good, clean of noise. Transmission distance measured up to 70 m with delay less than 200 ms. The average heart rate calculation was in error 3%

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 133 tautan kepenulisan bersama · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Singaperbangsa Karawang
  • Hasanuddin University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Muhammad NawawiAfiliasi tidak diketahui2
Irman HermadiAfiliasi tidak diketahui2
Salnuddin SalnuddinAfiliasi tidak diketahui2
I Wayan NurjayaAfiliasi tidak diketahui2
Nyoman M N NatihAfiliasi tidak diketahui2
Totok HestirianotoAfiliasi tidak diketahui2
Shofia AminAfiliasi tidak diketahui1
Dahmiri DahmiriAfiliasi tidak diketahui1
Rista Aldilla SyafriAfiliasi tidak diketahui1
Abdul HadiUniversity of Singaperbangsa Karawang1
Nurul AfifahAfiliasi tidak diketahui1
M AminAfiliasi tidak diketahui1
Fajar AfriantoAfiliasi tidak diketahui1
Roma AprihenAfiliasi tidak diketahui1
Riski MaulanaAfiliasi tidak diketahui1
Hanif Naufal ZuhdiAfiliasi tidak diketahui1
Elwita FebrinolaAfiliasi tidak diketahui1
Sindy KiraraAfiliasi tidak diketahui1
Mella AstikaAfiliasi tidak diketahui1
Yulia PutriAfiliasi tidak diketahui1
Muhammad AliAfiliasi tidak diketahui1
Rohman WilianAfiliasi tidak diketahui1
Anjas Kesuma PutraAfiliasi tidak diketahui1
Rohman WillianAfiliasi tidak diketahui1
Izmi Anisa OktavianiAfiliasi tidak diketahui1
Sry RositaAfiliasi tidak diketahui1
Dyta DahliyantiAfiliasi tidak diketahui1
Sumarni SumarniHasanuddin University1
Wahyudi FirmansyahAfiliasi tidak diketahui1
Di IkhwalAfiliasi tidak diketahui1
Lukman HandokoAfiliasi tidak diketahui1
Agry AlfiahAfiliasi tidak diketahui1
HayatiAfiliasi tidak diketahui1
Naila Eka FazlinAfiliasi tidak diketahui1
Nofrivul NofrivulAfiliasi tidak diketahui1
SYUKRI ISKAAfiliasi tidak diketahui1
Elsy RenieAfiliasi tidak diketahui1
Ifelda NengsihAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ar-raniry.ac.id/index.php/circuit/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Simulasi Alat Photoplethysmograph (PPG)</dc:title>
	<dc:creator xml:lang="en">Jaya, Indra</dc:creator>
	<dc:creator xml:lang="en">Wisma, Wisma</dc:creator>
	<dc:subject xml:lang="en">Heart</dc:subject>
	<dc:subject xml:lang="en">Photoplethysmograph (PPG)</dc:subject>
	<dc:subject xml:lang="en">monitored</dc:subject>
	<dc:subject xml:lang="en">online</dc:subject>
	<dc:subject xml:lang="en">telemedicine</dc:subject>
	<dc:description xml:lang="en">Heart is a vital organ in the human body. The heart functions circulated the blood throughout the body. The volume of blood in a body organ will vary due to blood pumping by the heart. Photoplethysmograph (PPG) is a device that can detect changes in blood volume using optical sensors. The purpose of this research is to make Photoplethysmograph monitoring system online. That is a device to monitor blood volume changes and display the change graph. Fluctuations in blood volume changes are influenced by the rhythm of blood pumping by the heart. Each peak on the PPG signal is correlated with one heartbeat. Photoplethysmograph charts can be used to determine the condition and abnormalities of a person's heart.
Photoplethysmograph system online is realized in the form of sensors, amplifiers, LPF, ADC, and microcontroller as a serial interface, wiz610wi module, and web applications as online PPG graph viewer. Sensors composed of red LED and photoresistor (LDR) are placed on the fingers. The rays emitted by the LEDs are received by the LDR. The signals received by the LDR vary according to the volume of blood changes. The sensor output signal is then amplified and filtered. Incoming filter output signal ADC, serial interface by AT89C2051 then by wiz610wi module transmitted for display and monitored. Obtained Devices and apps created have worked well. The signal shown is pretty good, clean of noise. Transmission distance measured up to 70 m with delay less than 200 ms. The average heart rate calculation was in error 3%</dc:description>
	<dc:publisher xml:lang="en">PTE FTK UIN Ar-Raniry</dc:publisher>
	<dc:date>2017-11-02</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/2081</dc:identifier>
	<dc:identifier>10.22373/crc.v1i2.2081</dc:identifier>
	<dc:source xml:lang="en">Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro; Vol. 1 No. 2 (2017)</dc:source>
	<dc:source>2549-3701</dc:source>
	<dc:source>2549-3698</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/2081/1544</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2017 CIRCUIT: Jurnal Ilmiah Pendidikan Teknik Elektro</dc:rights>
</oai_dc:dc>