Melola Discovery

← Melola Discovery

Jurnal Tanpa peringkat SINTA

Karakteristik Disturbansi di Rentang Frekuensi 9-150 kHz Pada Sistem UPS Berbeban Induktif

Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro · Vol. 4 No. 1 (2020) · hlm. 20–32

DOI
10.22373/crc.v4i1.6276
ISSN
2549-3701, 2549-3698
Terbit
2020-03-30
Penerbit
PTE FTK UIN Ar-Raniry
Bahasa
eng

Abstrak

In every UPS device there are power electronic components including inverters, therefore using an inverter will cause voltage disturbances at high frequency because the switching frequency of the inverter is at high frequency. Data recorded by the oscilloscope along with the Picolog Recorder software and processed by Matlab software to make it more efficient. Research conducted when the UPS uses dual conversion mode and with inductive load variations 0.35 H, 0.7 H, 1.4 H and 2.8 H. The test results show that voltage disturbances occur in three dominant frequency ranges at each level of load variations are 9-19 kHz, 20-30 kHz and 31-41 kHz. In the condition of 10% loading rate with a load of 0.35 H the peak voltage disturbances occur at 81.17 mV in frequency of 9.2 kHz and at the condition of the 75% loading rate with 2.8 H load the peak voltage disturbances that occur at 92.20 mV in frequency of 9.6 kHz. The disturbances voltage increases with the increasing of inductive loads that connected to UPS.

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 25 tautan kepenulisan bersama · 12 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Indonesia
  • National Research and Innovation Agency
  • Telkom University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Faiz HusnayainUniversity of Indonesia2
M. Muaz Afra YunardiUniversity of Indonesia1
Purnomo Sidi PriambodoUniversity of Indonesia1
Wahyudi HasbiNational Research and Innovation Agency1
Dewi AnggraeniNational Research and Innovation Agency1
Eriko Nasemudin NasserTelkom University1
Yus NataliTelkom University1
Erick Satriyo GumilangUniversity of Indonesia1
Chairul HudayaUniversity of Indonesia1
Faizal TamimUniversity of Indonesia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ar-raniry.ac.id/index.php/circuit/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Karakteristik Disturbansi di Rentang Frekuensi 9-150 kHz Pada Sistem UPS Berbeban Induktif</dc:title>
	<dc:creator xml:lang="en">Pratama, Rheo Loridho</dc:creator>
	<dc:creator xml:lang="en">Sudiarto, Budi</dc:creator>
	<dc:subject xml:lang="en">inverter</dc:subject>
	<dc:subject xml:lang="en">UPS</dc:subject>
	<dc:subject xml:lang="en">disturbances</dc:subject>
	<dc:subject xml:lang="en">frequency</dc:subject>
	<dc:description xml:lang="en">In every UPS device there are power electronic components including inverters, therefore using an inverter will cause voltage disturbances at high frequency because the switching frequency of the inverter is at high frequency. Data recorded by the oscilloscope along with the Picolog Recorder software and processed by  Matlab software to make it more efficient. Research conducted when the UPS uses dual conversion mode and with inductive load variations 0.35 H, 0.7 H, 1.4 H and 2.8 H. The test results show that voltage disturbances occur in three dominant frequency ranges at each level of load variations are 9-19 kHz, 20-30 kHz and 31-41 kHz. In the condition of 10% loading rate with a load of 0.35 H the peak voltage disturbances occur at 81.17 mV in frequency of 9.2 kHz and at the condition of the 75% loading rate with 2.8 H load the peak voltage disturbances that occur at 92.20 mV in frequency of 9.6 kHz. The disturbances voltage increases with the increasing of  inductive loads that connected to UPS.</dc:description>
	<dc:publisher xml:lang="en">PTE FTK UIN Ar-Raniry</dc:publisher>
	<dc:date>2020-03-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/6276</dc:identifier>
	<dc:identifier>10.22373/crc.v4i1.6276</dc:identifier>
	<dc:source xml:lang="en">Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro; Vol. 4 No. 1 (2020); 20-32</dc:source>
	<dc:source>2549-3701</dc:source>
	<dc:source>2549-3698</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/6276/4004</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2020 CIRCUIT: Jurnal Ilmiah Pendidikan Teknik Elektro</dc:rights>
</oai_dc:dc>