Abstrak
In every UPS device there are power electronic components including inverters, therefore using an inverter will cause voltage disturbances at high frequency because the switching frequency of the inverter is at high frequency. Data recorded by the oscilloscope along with the Picolog Recorder software and processed by Matlab software to make it more efficient. Research conducted when the UPS uses dual conversion mode and with inductive load variations 0.35 H, 0.7 H, 1.4 H and 2.8 H. The test results show that voltage disturbances occur in three dominant frequency ranges at each level of load variations are 9-19 kHz, 20-30 kHz and 31-41 kHz. In the condition of 10% loading rate with a load of 0.35 H the peak voltage disturbances occur at 81.17 mV in frequency of 9.2 kHz and at the condition of the 75% loading rate with 2.8 H load the peak voltage disturbances that occur at 92.20 mV in frequency of 9.6 kHz. The disturbances voltage increases with the increasing of inductive loads that connected to UPS.
Jaringan kolaborasi para penulis
12 penulis ·
25 tautan kepenulisan bersama
· 12 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
University of Indonesia National Research and Innovation Agency Telkom University
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ar-raniry.ac.id/index.php/circuit/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Karakteristik Disturbansi di Rentang Frekuensi 9-150 kHz Pada Sistem UPS Berbeban Induktif</dc:title>
<dc:creator xml:lang="en">Pratama, Rheo Loridho</dc:creator>
<dc:creator xml:lang="en">Sudiarto, Budi</dc:creator>
<dc:subject xml:lang="en">inverter</dc:subject>
<dc:subject xml:lang="en">UPS</dc:subject>
<dc:subject xml:lang="en">disturbances</dc:subject>
<dc:subject xml:lang="en">frequency</dc:subject>
<dc:description xml:lang="en">In every UPS device there are power electronic components including inverters, therefore using an inverter will cause voltage disturbances at high frequency because the switching frequency of the inverter is at high frequency. Data recorded by the oscilloscope along with the Picolog Recorder software and processed by Matlab software to make it more efficient. Research conducted when the UPS uses dual conversion mode and with inductive load variations 0.35 H, 0.7 H, 1.4 H and 2.8 H. The test results show that voltage disturbances occur in three dominant frequency ranges at each level of load variations are 9-19 kHz, 20-30 kHz and 31-41 kHz. In the condition of 10% loading rate with a load of 0.35 H the peak voltage disturbances occur at 81.17 mV in frequency of 9.2 kHz and at the condition of the 75% loading rate with 2.8 H load the peak voltage disturbances that occur at 92.20 mV in frequency of 9.6 kHz. The disturbances voltage increases with the increasing of inductive loads that connected to UPS.</dc:description>
<dc:publisher xml:lang="en">PTE FTK UIN Ar-Raniry</dc:publisher>
<dc:date>2020-03-30</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/6276</dc:identifier>
<dc:identifier>10.22373/crc.v4i1.6276</dc:identifier>
<dc:source xml:lang="en">Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro; Vol. 4 No. 1 (2020); 20-32</dc:source>
<dc:source>2549-3701</dc:source>
<dc:source>2549-3698</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/6276/4004</dc:relation>
<dc:rights xml:lang="en">Copyright (c) 2020 CIRCUIT: Jurnal Ilmiah Pendidikan Teknik Elektro</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Pratama, R. L., & Sudiarto, B. (2020). Karakteristik Disturbansi di Rentang Frekuensi 9-150 kHz Pada Sistem UPS Berbeban Induktif. Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro, 4(1), 20–32. https://doi.org/10.22373/crc.v4i1.6276
Salin
IEEE
R. L. Pratama and B. Sudiarto, “Karakteristik Disturbansi di Rentang Frekuensi 9-150 kHz Pada Sistem UPS Berbeban Induktif,” Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro, vol. 4, no. 1, pp. 20–32, 2020, doi: 10.22373/crc.v4i1.6276.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.