Optimalisasi Pemeliharaan, Pengujian, dan Penggantian Current Transformer Jenis OSKF-170

Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro · Vol. 6 No. 2 (2022) · hlm. 222–231

DOI
10.22373/crc.v6i2.14201
ISSN
2549-3701, 2549-3698
Terbit
2022-08-10
Penerbit
PTE FTK UIN Ar-Raniry
Bahasa
eng

Abstrak

The electric power distribution system on the transmission line side is carried out at the substati on, which contains several bays. However, containing the primary equipment discussed in this study regarding the Current Transformer (CT) of the CT OSKF-170 type, so that the electric power distribution system can be carried out optimally. The research location is substation area (GI), where the maintenance side is optimised and tested to prevent extensive damage to the substation's electric power distribution. If the CT has damage or disturbances such as current leakage that create inefficient power distribution losses, it can be replaced. Thus, this study examined the results of the insulation resistance measurement of more than 1000 G and on the secondary side the results were 100-500 MΩ. Then, the value of grounding resistance in the R, S, and T phases was less than 1Ω, the tan delta test yielded a measurement value of less than 1 percent, and the turns ratio in the transformer corresponds to the ratio value on the CT OSKF-170 nameplate. The outcomes of the tests were satisfactory in accordance with the criteria for CT maintenance standards.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sumatera Institute of Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sefrani Isdarmayani SiregarAfiliasi tidak diketahui1
Rachmad HidayatullahSumatera Institute of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ar-raniry.ac.id/index.php/circuit/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Optimalisasi Pemeliharaan, Pengujian, dan Penggantian Current Transformer Jenis OSKF-170</dc:title>
	<dc:creator xml:lang="en">Kasnalestari, Tria</dc:creator>
	<dc:creator xml:lang="en">Atmajaya, Gde KM</dc:creator>
	<dc:creator xml:lang="en">Baqaruzi, Syamsyarief</dc:creator>
	<dc:subject xml:lang="en">CT OSKF-170</dc:subject>
	<dc:subject xml:lang="en">Maintenance</dc:subject>
	<dc:subject xml:lang="en">Testing</dc:subject>
	<dc:subject xml:lang="en">Replaced</dc:subject>
	<dc:subject xml:lang="en">Optimal</dc:subject>
	<dc:description xml:lang="en">The electric power distribution system on the transmission line side is carried out at the substati on, which contains several bays. However, containing the primary equipment discussed in this study regarding the Current Transformer (CT) of the CT OSKF-170 type, so that the electric power distribution system can be carried out optimally. The research location is substation area (GI), where the maintenance side is optimised and tested to prevent extensive damage to the substation's electric power distribution. If the CT has damage or disturbances such as current leakage that create inefficient power distribution losses, it can be replaced. Thus, this study examined the results of the insulation resistance measurement of more than 1000 G and on the secondary side the results were 100-500 MΩ. Then, the value of grounding resistance in the R, S, and T phases was less than 1Ω, the tan delta test yielded a measurement value of less than 1 percent, and the turns ratio in the transformer corresponds to the ratio value on the CT OSKF-170 nameplate. The outcomes of the tests were satisfactory in accordance with the criteria for CT maintenance standards. </dc:description>
	<dc:publisher xml:lang="en">PTE FTK UIN Ar-Raniry</dc:publisher>
	<dc:date>2022-08-10</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/14201</dc:identifier>
	<dc:identifier>10.22373/crc.v6i2.14201</dc:identifier>
	<dc:source xml:lang="en">Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro; Vol. 6 No. 2 (2022); 222-231</dc:source>
	<dc:source>2549-3701</dc:source>
	<dc:source>2549-3698</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/14201/7210</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2022 Tria Kasnalestari, Gde KM Atmajaya, Syamsyarief Baqaruzi</dc:rights>
</oai_dc:dc>