Melola Discovery

← Melola Discovery

Jurnal Tanpa peringkat SINTA

Analysis of Control System and Signal Gain on Internet of Things-Based Electroencephalograph Circuit

Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro · Vol. 8 No. 1 (2024) · hlm. 87–103

DOI
10.22373/crc.v8i1.17058
ISSN
2549-3701, 2549-3698
Terbit
2024-03-01
Penerbit
PTE FTK UIN Ar-Raniry
Bahasa
eng

Abstrak

Epilepsy, characterized by recurrent seizures, exhibits changes in brain signals with amplitudes far exceeding normal conditions (up to 800µV versus 5-200µV). The varying phases of seizures (from a few seconds to minutes and accompanied by tonic-clonic seizures) pose a risk, especially in public spaces. In this case, we designed a wearable, portable EEG that provides real-time seizure detection. Our design uses four voltage amplifiers with good accuracy and one filter circuit (differential: 97.83%, non-inverting: 96.92%, 96.5%, and 97.99%). The signal is amplified for detection, then filtered for optimal compatibility with the microcontroller. In addition to amplified brain signals, balance, light, and GPS sensors are used as binary indicators of epileptic conditions. This data is transmitted via the IoT system, showing Quality of Service in the Good and Very Good categories in the parameters Packet Loss, Throughput, Delay and Jitter. It can be concluded that the transmission data system shows data in the good category and jitter value in the very good category.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Singaperbangsa Karawang
  • Universitas Amikom Yogyakarta
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Bayu Nadya KusumaUniversitas Amikom Yogyakarta1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ar-raniry.ac.id/index.php/circuit/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Analysis of Control System and Signal Gain on Internet of Things-Based Electroencephalograph Circuit</dc:title>
	<dc:creator xml:lang="en">Feryadi, Panji</dc:creator>
	<dc:creator xml:lang="en">Stefanie, Arnisa</dc:creator>
	<dc:creator xml:lang="en">Santoso, Dian Budhi</dc:creator>
	<dc:subject xml:lang="en">EEG</dc:subject>
	<dc:subject xml:lang="en">Brain Signal</dc:subject>
	<dc:subject xml:lang="en">Amplifier</dc:subject>
	<dc:subject xml:lang="en">Quality of Service</dc:subject>
	<dc:description xml:lang="en">Epilepsy, characterized by recurrent seizures, exhibits changes in brain signals with amplitudes far exceeding normal conditions (up to 800µV versus 5-200µV). The varying phases of seizures (from a few seconds to minutes and accompanied by tonic-clonic seizures) pose a risk, especially in public spaces. In this case, we designed a wearable, portable EEG that provides real-time seizure detection. Our design uses four voltage amplifiers with good accuracy and one filter circuit (differential: 97.83%, non-inverting: 96.92%, 96.5%, and 97.99%). The signal is amplified for detection, then filtered for optimal compatibility with the microcontroller. In addition to amplified brain signals, balance, light, and GPS sensors are used as binary indicators of epileptic conditions. This data is transmitted via the IoT system, showing Quality of Service in the Good and Very Good categories in the parameters Packet Loss, Throughput, Delay and Jitter. It can be concluded that the transmission data system shows data in the good category and jitter value in the very good category.</dc:description>
	<dc:publisher xml:lang="en">PTE FTK UIN Ar-Raniry</dc:publisher>
	<dc:date>2024-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/17058</dc:identifier>
	<dc:identifier>10.22373/crc.v8i1.17058</dc:identifier>
	<dc:source xml:lang="en">Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro; Vol. 8 No. 1 (2024); 87-103</dc:source>
	<dc:source>2549-3701</dc:source>
	<dc:source>2549-3698</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/17058/9205</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2024 Panji Feryadi, Arnisa Stefanie, Dian Budhi Santoso</dc:rights>
</oai_dc:dc>