Melola Discovery

← Melola Discovery

Jurnal

Analysis And Mitigation of Harmonics Transformer Distribution at PT. PLN Syiah Kuala

Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro · Vol. 8 No. 2 (2024) · hlm. 126–137

DOI
10.22373/crc.v8i2.19662
ISSN
2549-3701, 2549-3698
Terbit
2024-05-19
Penerbit
PTE FTK UIN Ar-Raniry
Bahasa
eng

Abstrak

Customers receive their electricity from distribution transformers; a disturbance will interfere with this process. High harmonics are typically the source of issues in distribution transformers. The distribution transformer at PT. PLN (Persero) ULP Syiahkuala has two issues: the neutral cable breaking and the main or secondary winding burning. Analyzing harmonics in distribution transformers at PT PLN (Persero) ULP Syiahkuala is the goal of this study. The goal of this study is to measure, examine, and assess the transformers at Syiahkuala ULP in order to select the best mitigation. One transformer's harmonic values were determined by the measurement findings to be out of compliance with requirements, necessitating the use of a variety of passive filters to reduce themThe results of THDi reduction using a passive filter are the values obtained for each phase R, S, and T. These values are in accordance with the established standards. From the results of harmonic mitigation using a passive filter, the results obtained in accordance with the THDv and THDi standards based on IEEE 159-2014 are 8% and 10%, respectively.

Kata kunci

Jaringan kolaborasi para penulis

16 penulis · 31 tautan kepenulisan bersama · 21 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Syiah Kuala
  • Politeknik Negeri Ujung Pandang
  • Universitas Halu Oleo
  • Hasanuddin University
  • University of Bangka Belitung
  • University of Mataram
  • Universitas Jambi
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
La HarimuUniversitas Halu Oleo1
I Wayan SuamaUniversitas Halu Oleo1
Jusmawati MassalesseHasanuddin University1
Muh. NurHasanuddin University1
Ramzi AdrimanUniversitas Syiah Kuala1
Muhazir IsUniversitas Syiah Kuala1
Sosiawan NusiferaUniversitas Jambi1
Gigih Ibnu PrayogaUniversity of Bangka Belitung1
Eries Dyah MustikariniUniversity of Bangka Belitung1
Kisman KismanUniversity of Mataram1
Mohd Zuwairi SaimanUniversity of Malaya1
Muhammad Ruswandi DjalalPoliteknik Negeri Ujung Pandang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ar-raniry.ac.id/index.php/circuit/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Analysis And Mitigation of Harmonics Transformer Distribution at PT. PLN Syiah     Kuala</dc:title>
	<dc:creator xml:lang="en">Faisal, Faisal</dc:creator>
	<dc:creator xml:lang="en">Lubisa, Ichsan Muhadis</dc:creator>
	<dc:creator xml:lang="en">Inayati, Ghina</dc:creator>
	<dc:creator xml:lang="en">Tarmizi, Tarmizi</dc:creator>
	<dc:subject xml:lang="en">Transformer</dc:subject>
	<dc:subject xml:lang="en">Harmonic</dc:subject>
	<dc:subject xml:lang="en">THD</dc:subject>
	<dc:subject xml:lang="en">Passive Filter</dc:subject>
	<dc:description xml:lang="en">Customers receive their electricity from distribution transformers; a disturbance will interfere with this process. High harmonics are typically the source of issues in distribution transformers. The distribution transformer at PT. PLN (Persero) ULP Syiahkuala has two issues: the neutral cable breaking and the main or secondary winding burning. Analyzing harmonics in distribution transformers at PT PLN (Persero) ULP Syiahkuala is the goal of this study. The goal of this study is to measure, examine, and assess the transformers at Syiahkuala ULP in order to select the best mitigation. One transformer's harmonic values were determined by the measurement findings to be out of compliance with requirements, necessitating the use of a variety of passive filters to reduce themThe results of THDi reduction using a passive filter are the values obtained for each phase R, S, and T. These values are in accordance with the established standards. From the results of harmonic mitigation using a passive filter, the results obtained in accordance with the THDv and THDi standards based on IEEE 159-2014 are 8% and 10%, respectively.</dc:description>
	<dc:publisher xml:lang="en">PTE FTK UIN Ar-Raniry</dc:publisher>
	<dc:date>2024-05-19</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/19662</dc:identifier>
	<dc:identifier>10.22373/crc.v8i2.19662</dc:identifier>
	<dc:source xml:lang="en">Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro; Vol. 8 No. 2 (2024); 126-137</dc:source>
	<dc:source>2549-3701</dc:source>
	<dc:source>2549-3698</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/19662/9825</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2024 Faisal, Ichsan Muhadis Lubis, Ghina Inayati, Tarmizi</dc:rights>
</oai_dc:dc>