Melola Discovery

← Melola Discovery

Jurnal Tanpa peringkat SINTA

The Digital Stethoscope with the Heart Rate Display: A Review and Its Implications for Learning

Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro · Vol. 8 No. 2 (2024) · hlm. 138–146

DOI
10.22373/crc.v8i2.22096
ISSN
2549-3701, 2549-3698
Terbit
2024-05-19
Penerbit
PTE FTK UIN Ar-Raniry
Bahasa
eng

Abstrak

A stethoscope is an important medical tool for initial examination of a patient's heartbeat, including detection of arrhythmias (heart rhythm disturbances). This digital stethoscope equipment has input voltage specifications from a power supply of +6 Volt DC and +12 Volt DC, condenser mic as a stethoscope sensor, LED as a heart rate indicator, seven segments as a heartbeat display and timer, earphones as a tool for hearing sounds heartbeat and amplifier circuit. The research was carried out using system operations and supporting blocks to analyze the results of tool testing. The voltage measurements in the tool support block were obtained according to the plan, the start timer circuit voltage was 4.6 VDC (working), the NE555N IC output voltage was 5.8 VDC and the voltage at the transistor collector leg was measured when the condenser microphone received a sound signal. A digital stethoscope can display heartbeats for a duration of 15 seconds, so it still requires manual calculations to determine the heartbeat for 1 minute. Based on the test results, this Stethoscope will be an effective learning aid to improve students' medical skills

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ar-raniry.ac.id/index.php/circuit/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">The Digital Stethoscope with the Heart Rate Display: A Review and Its Implications for Learning</dc:title>
	<dc:creator xml:lang="en">Fuady, Khairul</dc:creator>
	<dc:creator xml:lang="en">Nanda, Nanda</dc:creator>
	<dc:creator xml:lang="en">Zulisa, Eva</dc:creator>
	<dc:subject xml:lang="en">Stethoscope</dc:subject>
	<dc:subject xml:lang="en">heart rate</dc:subject>
	<dc:subject xml:lang="en">seven segment</dc:subject>
	<dc:description xml:lang="en">A stethoscope is an important medical tool for initial examination of a patient's heartbeat, including detection of arrhythmias (heart rhythm disturbances). This digital stethoscope equipment has input voltage specifications from a power supply of +6 Volt DC and +12 Volt DC, condenser mic as a stethoscope sensor, LED as a heart rate indicator, seven segments as a heartbeat display and timer, earphones as a tool for hearing sounds heartbeat and amplifier circuit. The research was carried out using system operations and supporting blocks to analyze the results of tool testing. The voltage measurements in the tool support block were obtained according to the plan, the start timer circuit voltage was 4.6 VDC (working), the NE555N IC output voltage was 5.8 VDC and the voltage at the transistor collector leg was measured when the condenser microphone received a sound signal. A digital stethoscope can display heartbeats for a duration of 15 seconds, so it still requires manual calculations to determine the heartbeat for 1 minute. Based on the test results, this Stethoscope will be an effective learning aid to improve students' medical skills</dc:description>
	<dc:publisher xml:lang="en">PTE FTK UIN Ar-Raniry</dc:publisher>
	<dc:date>2024-05-19</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/22096</dc:identifier>
	<dc:identifier>10.22373/crc.v8i2.22096</dc:identifier>
	<dc:source xml:lang="en">Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro; Vol. 8 No. 2 (2024); 138-146</dc:source>
	<dc:source>2549-3701</dc:source>
	<dc:source>2549-3698</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/22096/9826</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2024 Khairul Fuady, Nanda, Eva Zulisa</dc:rights>
</oai_dc:dc>