Melola Discovery

← Melola Discovery

Jurnal

Test Hybrid PV System Performance Against Load Variations

Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro · Vol. 9 No. 1 (2025) · hlm. 9–23

DOI
10.22373/crc.v9i1.23284
ISSN
2549-3701, 2549-3698
Terbit
2025-01-07
Penerbit
PTE FTK UIN Ar-Raniry
Bahasa
en

Abstrak

The depletion of fossil fuels has driven significant changes in the global electricity system. Solar Power Plants (PLTS) as a renewable energy source have shown the potential to contribute up to 25% of global electricity generation by 2050. The electricity system often experiences disturbances that can affect its performance and reliability. This study examines the performance of a 1.2 kW hybrid PV system under various load conditions. The system was tested with load variations of 2%, 7%, 22%, and 26% to assess its efficiency and performance. Despite a slight voltage drop of 4V Vac (-1.82%) at higher loads, the hybrid PV system consistently maintained a voltage range of 216-220V Vac, which meets the standard requirements. The system demonstrated high efficiency, averaging over 95%, with a peak efficiency reaching 98.5% at 2% load. These results confirm the effectiveness, safety, and reliability of the system under various load conditions. The findings are based on direct testing and measurements of a 1.2 kW hybrid PV system to evaluate the impact of load variations on its performance. The 1.2 kW hybrid PV system has been proven to be effective, safe and reliable in the face of load variations. These findings support the potential implementation of hybrid PV systems as a future renewable energy solution in the electricity sector

Kata kunci

Jaringan kolaborasi para penulis

31 penulis · 107 tautan kepenulisan bersama · 36 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • State University of Malang
  • Mulawarman University
  • Universiti Teknologi MARA
  • Diponegoro University
  • Tun Hussein Onn University of Malaysia
  • Universitas Jember
  • Universitas Muhammadiyah Surabaya
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sujito SujitoState University of Malang6
Aji Prasetya WibawaState University of Malang3
Norzanah RosminUniversity of Technology Malaysia3
Arif Nur AfandiState University of Malang3
Yuni RahmawatiState University of Malang3
Gregorius Paulus Mario Laka KakiState University of Malang3
Ayu PurwatiningsihState University of Malang3
Widjonarko WidjonarkoDiponegoro University1
Wahyu Mulyo UtomoTun Hussein Onn University of Malaysia1
Fatah Ridha BaskaraUniversitas Jember1
Marwan RosyadiUniversitas Muhammadiyah Surabaya1
Achmad TaufiqState University of Malang1
Suprayitno SuprayitnoState University of Malang1
Ahmad DardiriState University of Malang1
AriprihartaAfiliasi tidak diketahui1
Muhammad Afnan HabibiState University of Malang1
Gabrielley Ferdhiansyah RiyadiState University of Malang1
Langlang GumilarState University of Malang1
Riya MustikasariState University of Malang1
Muhammad Jazuli ShubhiState University of Malang1
Dekki WidiatmokoPoliteknik Angkatan Darat1
Teguh WirawanMulawarman University1
Subur P. PasaribuMulawarman University1
Aman Sentosa PanggabeanMulawarman University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ar-raniry.ac.id/index.php/circuit/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Test Hybrid PV System Performance Against Load Variations</dc:title>
	<dc:creator xml:lang="en">Aripriharta, Aripriharta</dc:creator>
	<dc:creator xml:lang="en">Amin, Muhammad Adib</dc:creator>
	<dc:creator xml:lang="en">Sujito, Sujito</dc:creator>
	<dc:creator xml:lang="en">Faiz, Mohamad Rodhi</dc:creator>
	<dc:creator xml:lang="en">Bagaskoro, Muhammad Cahyo</dc:creator>
	<dc:creator xml:lang="en">Susilo, Suhiro Wongso</dc:creator>
	<dc:creator xml:lang="en">Omar, Saodah</dc:creator>
	<dc:subject xml:lang="en">Hybrid PV System</dc:subject>
	<dc:subject xml:lang="en">Load Variation</dc:subject>
	<dc:subject xml:lang="en">Performance</dc:subject>
	<dc:subject xml:lang="en">Efficiency</dc:subject>
	<dc:subject xml:lang="en">Output Voltage.</dc:subject>
	<dc:subject xml:lang="en">renewable energy</dc:subject>
	<dc:description xml:lang="en">The depletion of fossil fuels has driven significant changes in the global electricity system. Solar Power Plants (PLTS) as a renewable energy source have shown the potential to contribute up to 25% of global electricity generation by 2050. The electricity system often experiences disturbances that can affect its performance and reliability. This study examines the performance of a 1.2 kW hybrid PV system under various load conditions. The system was tested with load variations of 2%, 7%, 22%, and 26% to assess its efficiency and performance. Despite a slight voltage drop of 4V Vac (-1.82%) at higher loads, the hybrid PV system consistently maintained a voltage range of 216-220V Vac, which meets the standard requirements. The system demonstrated high efficiency, averaging over 95%, with a peak efficiency reaching 98.5% at 2% load. These results confirm the effectiveness, safety, and reliability of the system under various load conditions. The findings are based on direct testing and measurements of a 1.2 kW hybrid PV system to evaluate the impact of load variations on its performance. The 1.2 kW hybrid PV system has been proven to be effective, safe and reliable in the face of load variations. These findings support the potential implementation of hybrid PV systems as a future renewable energy solution in the electricity sector</dc:description>
	<dc:publisher xml:lang="en">PTE FTK UIN Ar-Raniry</dc:publisher>
	<dc:date>2025-01-07</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:identifier>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/23284</dc:identifier>
	<dc:identifier>10.22373/crc.v9i1.23284</dc:identifier>
	<dc:source xml:lang="en">Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro; Vol. 9 No. 1 (2025); 9-23</dc:source>
	<dc:source>2549-3701</dc:source>
	<dc:source>2549-3698</dc:source>
	<dc:language>en</dc:language>
	<dc:rights xml:lang="en">Copyright (c) 2024 Aripriharta, Muhammad Adib Amin, Sujito, Mohamad Rodhi Faiz, Muhammad Cahyo Bagaskoro, Suhiro Wongso Susilo, Saodah Omar</dc:rights>
</oai_dc:dc>