Design and Development of a Non-Invasive Blood Glucose Level Measurement Device Based on Arduino Uno and Near-Infrared (NIR) Sensor

Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro · Vol. 10 No. 1 (2026) · hlm. 40–55

DOI
10.22373/5yqqya14
ISSN
2549-3701, 2549-3698
Terbit
2026-02-10
Penerbit
PTE FTK UIN Ar-Raniry
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Diabetes Mellitus is one of the leading causes of death in the world. Therefore, regular monitoring of blood sugar levels is very important to prevent complications. However, monitoring blood sugar using conventional-invasive methods can cause discomfort and risk causing infection. This study aims to design a non-invasive blood sugar level measuring device based on Arduino Uno R3 using a BPW34 Near-Infrared (NIR) sensor reinforced with an LM358 operational amplifier. The measurement results are displayed on a 16x2 LCD and sent via Telegram Bot in real-time. This study focused on Type 2 Diabetes Mellitus and was tested on 10 participants aged 18-45 years with some patients in fasting and some not fasting conditions. The test results showed good accuracy with a Mean Absolute Error of 2.48%, minimal systematic bias (-0.08%), and a very strong correlation coefficient (r = 0.996436) against invasive methods. All measurement data meets the tolerance criteria of ISO 15197:2013 with an error range of -4.55% to +3.16%, indicating that this tool has the potential to be a more convenient and safer alternative for initial blood sugar level screening

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Muhammadiyah Gresik
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ar-raniry.ac.id/index.php/circuit/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Design and Development of a Non-Invasive Blood Glucose Level Measurement Device Based on Arduino Uno and Near-Infrared (NIR) Sensor</dc:title>
	<dc:creator xml:lang="en">Baiturrohmah, Siti</dc:creator>
	<dc:creator xml:lang="en"> Alfi Zuhriya Khoirunnisaa</dc:creator>
	<dc:description xml:lang="en">Diabetes Mellitus is one of the leading causes of death in the world. Therefore, regular monitoring of blood sugar levels is very important to prevent complications. However, monitoring blood sugar using conventional-invasive methods can cause discomfort and risk causing infection. This study aims to design a non-invasive blood sugar level measuring device based on Arduino Uno R3 using a BPW34 Near-Infrared (NIR) sensor reinforced with an LM358 operational amplifier. The measurement results are displayed on a 16x2 LCD and sent via Telegram Bot in real-time. This study focused on Type 2 Diabetes Mellitus and was tested on 10 participants aged 18-45 years with some patients in fasting and some not fasting conditions. The test results showed good accuracy with a Mean Absolute Error of 2.48%, minimal systematic bias (-0.08%), and a very strong correlation coefficient (r = 0.996436) against invasive methods. All measurement data meets the tolerance criteria of ISO 15197:2013 with an error range of -4.55% to +3.16%, indicating that this tool has the potential to be a more convenient and safer alternative for initial blood sugar level screening</dc:description>
	<dc:publisher xml:lang="en">PTE FTK UIN Ar-Raniry</dc:publisher>
	<dc:date>2026-02-10</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/33883</dc:identifier>
	<dc:identifier>10.22373/5yqqya14</dc:identifier>
	<dc:source xml:lang="en">Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro; Vol. 10 No. 1 (2026); 40-55</dc:source>
	<dc:source>2549-3701</dc:source>
	<dc:source>2549-3698</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ar-raniry.ac.id/index.php/circuit/article/view/33883/12536</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2026 Siti Baiturrohmah, Alfi Zuhriya Khoirunnisa</dc:rights>
	<dc:rights xml:lang="en">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>