Melola Discovery

← Melola Discovery

Journal

Hotel Building Reliability Towards Building Age

Elkawnie · Vol. 6 No. 2 (2020) · pp. 201–212

DOI
10.22373/ekw.v6i2.6313
ISSN
2460-8912, 2460-8920
Published
2020-12-30
Publisher
Faculty of Science and Technology Universitas Islam Negeri Ar-Raniry
Language
eng

Abstract

Abstract: Mahara Hotel is a tourism-supporting facility and infrastructure first established in Central Aceh District in 1999. This 3-story hotel used a reinforced concrete frame structure, and as time goes by, the service capacity of the building would decrease. This condition was suspected to affect quality and user convenience. Anticipate the older age of the building, and better maintenance management is applied so that the proper building’s function can be maintained. The purpose of this study was to assess the reliability of 20 year-established hotel buildings. The method was a descriptive analysis. Data were analyzed based on the guidelines of Technical Procedures for Guidelines for Certificate of Eligibility for Functions (SLF) of Buildings Regulation of Minister of Public Works No. 25/PRT/M/2007. Based on the results, the reliability value of the Mahara Hotel building was unreliable (66.75 %), less than the SLF guidelines (at least 75 %). Some components that caused a low level of reliability to include utility and fire protection components (20.34 %) and accessibility components (3.11 %). The effective and efficient component in increasing the reliability of the building was the utility and fire protection components by not requiring major demolition.Abstrak: Hotel Mahara merupakan sarana dan prasarana penunjang pariwisata yang pertama kali berdiri di Kabupaten Aceh Tengah pada tahun 1999. Hotel berlantai 3 ini menggunakan struktur rangka beton bertulang dan seiring dengan berjalannya waktu, daya layan gedung akan semakin menurun. Kondisi ini ditenggarai akan mempengaruhi kualitas dan kenyamanan pengguna. Untuk mengantisipasi hal tersebut, maka semakin tua umur bangunan, seharusnya didukung dengan penerapan manajemen pemeliharaan yang baik agar kelayakan fungsi dari bangunan dapat dipertahankan. Tujuan dari penelitian ini untuk menilai keandalan bangunan hotel setelah berumur 20 tahun. Metode yang digunakan adalah analisis deskriptif. Data dianalisis berdasarkan panduan Teknis Tata Cara Pedoman Sertifikat Laik Fungsi (SLF) Bangunan Gedung Peraturan Menteri Pekerjaan Umum No. 25/PRT/M/2007. Berdasarkan hasil penelitian, nilai keandalan bangunan gedung Hotel Mahara termasuk tidak andal yaitu sebesar 66.75 %, kurang dari yang dipersyaratkan oleh pedoman SLF tersebut yaitu minimal 75 %. Beberapa komponen yang menyebabkan rendahnya tingkat keandalan anatara lain komponen utilitas dan proteksi kebakaran sebesar 20.34 % serta komponen aksesibilitas sebesar 3.11 %. Komponen yang efektif serta efisien dalam menaikkan tingkat keandalan bangunan gedung tersebut adalah komponen utilitas dan proteksi kebakaran dengan tidak mengharuskan pembongkaran yang besar.

Keywords

Collaboration network of the authors

40 authors · 109 co-authorship links · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Jordan University of Science and Technology
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Ahmad MustafaJordan University of Science and Technology9
Muslim TadjuddahAffiliation unknown9
Naslina AliminaAffiliation unknown8
Syamsul KamriAffiliation unknown6
La AnadiAffiliation unknown6
Hasnia AramiAffiliation unknown5
Muhammad Ali SarongAffiliation unknown3
Muhammad RidhaAffiliation unknown3
Isnawati IsnawatiAffiliation unknown2
Fitria UlfaAffiliation unknown2
Rizka ViantiAffiliation unknown2
Yuri GagarinAffiliation unknown2
Khairil KhairilAffiliation unknown2
Djufri DjufriAffiliation unknown2
Suhaimi SuhaimiAffiliation unknown2
Kadek LindawatiAffiliation unknown1
Romy KetjulanAffiliation unknown1
La Ode Abdul MuisAffiliation unknown1
Ander IbrahimAffiliation unknown1
Resnawati ResnawatiAffiliation unknown1
Yusril YusrilAffiliation unknown1
Nur InsyaniaAffiliation unknown1
Fina MirantiAffiliation unknown1
Lusi Dwi AprilianiAffiliation unknown1
Muh Ikhsan TaherAffiliation unknown1
Dito HermansyahAffiliation unknown1
Fajar Indah NingsihAffiliation unknown1
Ermayanti IshakAffiliation unknown1
Abdul LatifAffiliation unknown1
Nurlela NurlelaAffiliation unknown1
Asrawati NendeAffiliation unknown1
Kumala Sari Ode MurhumAffiliation unknown1
La Ode Abdul Rajab NadiaAffiliation unknown1
La Ode FentiAffiliation unknown1
Suhardin SuhardinAffiliation unknown1
Ika Rezki AmaliaAffiliation unknown1
Nur SyamsiAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://jurnal.ar-raniry.ac.id/index.php/elkawnie/oai, first harvested 7 Nov 2026, last seen 7 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Hotel Building  Reliability Towards Building Age</dc:title>
	<dc:creator xml:lang="en">Indrawansyah, Syukri</dc:creator>
	<dc:creator xml:lang="en">Abdullah, Abdullah</dc:creator>
	<dc:creator xml:lang="en">Oktaviani, Cut Zukhrina</dc:creator>
	<dc:subject xml:lang="en">Assessment</dc:subject>
	<dc:subject xml:lang="en">Reliability</dc:subject>
	<dc:subject xml:lang="en">Care</dc:subject>
	<dc:subject xml:lang="en">Building</dc:subject>
	<dc:description xml:lang="en">Abstract: Mahara Hotel is a tourism-supporting facility and infrastructure first established in Central Aceh District in 1999. This 3-story hotel used a reinforced concrete frame structure, and as time goes by, the service capacity of the building would decrease. This condition was suspected to affect quality and user convenience. Anticipate the older age of the building, and better maintenance management is applied so that the proper building’s function can be maintained. The purpose of this study was to assess the reliability of 20 year-established hotel buildings. The method was a descriptive analysis. Data were analyzed based on the guidelines of Technical Procedures for Guidelines for Certificate of Eligibility for Functions (SLF) of Buildings Regulation of  Minister of Public Works No. 25/PRT/M/2007. Based on the results, the reliability value of the Mahara Hotel building was unreliable (66.75 %), less than the SLF guidelines (at least 75 %). Some components that caused a low level of reliability to include utility and fire protection components (20.34 %) and accessibility components (3.11 %). The effective and efficient component in increasing the reliability of the building was the utility and fire protection components by not requiring major demolition.Abstrak: Hotel Mahara merupakan sarana dan prasarana penunjang pariwisata yang pertama kali berdiri di Kabupaten Aceh Tengah pada tahun 1999. Hotel berlantai 3 ini menggunakan struktur rangka beton bertulang dan seiring dengan berjalannya waktu, daya layan gedung akan semakin menurun. Kondisi ini ditenggarai akan mempengaruhi kualitas dan kenyamanan pengguna. Untuk mengantisipasi hal tersebut, maka semakin tua umur bangunan, seharusnya didukung dengan penerapan manajemen pemeliharaan yang baik agar kelayakan fungsi dari bangunan dapat dipertahankan. Tujuan dari penelitian ini untuk menilai keandalan bangunan hotel setelah berumur 20 tahun. Metode yang digunakan adalah analisis deskriptif. Data dianalisis berdasarkan panduan Teknis Tata Cara Pedoman Sertifikat Laik Fungsi (SLF) Bangunan Gedung Peraturan Menteri Pekerjaan Umum No. 25/PRT/M/2007. Berdasarkan hasil penelitian, nilai keandalan bangunan gedung Hotel Mahara termasuk tidak andal yaitu sebesar 66.75 %, kurang dari yang dipersyaratkan oleh pedoman SLF tersebut yaitu minimal 75 %. Beberapa komponen yang menyebabkan rendahnya tingkat keandalan anatara lain komponen utilitas dan proteksi kebakaran sebesar 20.34 % serta komponen aksesibilitas sebesar 3.11 %. Komponen yang efektif serta efisien dalam menaikkan tingkat keandalan bangunan gedung tersebut adalah komponen utilitas dan proteksi kebakaran dengan tidak mengharuskan pembongkaran yang besar.</dc:description>
	<dc:publisher xml:lang="en">Faculty of Science and Technology Universitas Islam Negeri Ar-Raniry</dc:publisher>
	<dc:date>2020-12-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:format>image/jpeg</dc:format>
	<dc:format>application/vnd.openxmlformats-officedocument.spreadsheetml.sheet</dc:format>
	<dc:format>application/vnd.openxmlformats-officedocument.spreadsheetml.sheet</dc:format>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ar-raniry.ac.id/index.php/elkawnie/article/view/6313</dc:identifier>
	<dc:identifier>10.22373/ekw.v6i2.6313</dc:identifier>
	<dc:source xml:lang="en">Elkawnie; Vol. 6 No. 2 (2020); 201-212</dc:source>
	<dc:source>2460-8912</dc:source>
	<dc:source>2460-8920</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ar-raniry.ac.id/index.php/elkawnie/article/view/6313/pdf</dc:relation>
	<dc:relation>https://jurnal.ar-raniry.ac.id/index.php/elkawnie/article/view/6313/10805</dc:relation>
	<dc:relation>https://jurnal.ar-raniry.ac.id/index.php/elkawnie/article/view/6313/10875</dc:relation>
	<dc:relation>https://jurnal.ar-raniry.ac.id/index.php/elkawnie/article/view/6313/10881</dc:relation>
	<dc:relation>https://jurnal.ar-raniry.ac.id/index.php/elkawnie/article/view/6313/10884</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2020 Syukri Indrawansyah, Abdullah, Cut Zukhrina Oktaviani</dc:rights>
</oai_dc:dc>