Melola Discovery

← Melola Discovery

Journal No SINTA rank

Effect of Electrode Distance, Stirring Speed and Contact Time on Removal of Polyethylene Microplastics (Microbeads) Using Electrocoagulation Method

Elkawnie · Vol. 10 No. 1 (2024) · pp. 158–168

DOI
10.22373/ekw.v10i1.22195
ISSN
2460-8912, 2460-8920
Published
2024-06-22
Publisher
Faculty of Science and Technology Universitas Islam Negeri Ar-Raniry
Language
eng

Abstract

Abstract: Daily use of personal care products containing microbeads causes severe problems for the aquatic environment. Greywater is a pathway for microbeads to enter domestic waste and wastewater treatment plants (WWTPs) from personal care products. Their tiny size and hydrophobic nature allow microbeads to escape from WWTPs and end up in surface water. Therefore, processing efforts are needed to remove microbeads, one of which is using the electrocoagulation method with aluminum (Al) electrodes. This study aims to evaluate the performance of the electrocoagulation process using Al electrodes arranged in a monopolar configuration in a batch reactor to see the effect of variations in distance between electrodes of 1, 2.5, and 3.5 cm, stirring speed of 150, 200, and 250 rpm; with the contact time 60, 120, and 180 minutes in removing microbeads from artificial wastewater. This research shows that the best efficiency value of 99.30% occurs in operating conditions with a distance between electrodes of 2.5 cm, a stirring speed of 150 rpm, and a contact time of 180 minutes. ANOVA results showed that distance between electrodes, stirring speed, and contact time significantly affected microbead removal efficiency (p<0.05). The results of this research can be a reference for alternative tertiary processing at WWTPs.Abstrak: Penggunaan produk perawatan pribadi sehari-hari yang mengandung microbeads menyebabkan masalah serius bagi lingkungan perairan. Greywater merupakan jalur masuknya microbeads ke dalam limbah domestik dan instalasi pengolahan air limbah (IPAL) dari produk perawatan pribadi. Ukurannya yang sangat kecil dan sifat hidrofobiknya memungkinkan microbeads keluar dari IPAL dan berakhir ke air permukaan. Oleh karena itu diperlukan upaya pengolahan untuk menyisihkan microbeads, salah satunya dengan menggunakan metode elektrokoagulasi dengan elektroda aluminium (Al). Penelitian ini bertujuan untuk mengevaluasi kinerja proses elektrokoagulasi menggunakan elektroda Al yang disusun dalam konfigurasi monopolar dalam reaktor batch untuk melihat pengaruh variasi jarak antar elektroda 1, 2,5, dan 3,5 cm, kecepatan pengadukan 150, 200, dan 250 rpm, dan waktu kontak 60, 120, dan 180 menit dalam menyisihkan microbeads dari air limbah artifisial. Penelitian ini menunjukkan bahwa nilai efisiensi terbaik sebesar 99,30% terjadi pada kondisi operasi dengan jarak antar elektroda 2,5 cm, kecepatan pengadukan 150 rpm, dan waktu kontak 180 menit. Hasil ANOVA menunjukkan bahwa jarak antar elektroda, kecepatan pengadukan, dan waktu kontak berpengaruh signifikan terhadap efisiensi penyisihan microbead (p<0,05). Hasil penelitian ini dapat menjadi referensi alternatif pengolahan tersier di IPAL.

Keywords

Collaboration network of the authors

28 authors · 117 co-authorship links · 30 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Sumatera Utara
  • Andalas University
  • Riau University
  • National University of Malaysia
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Shinta IndahAndalas University3
Calysta Deli Ad’haniAndalas University1
Shinta SilviaAndalas University1
Fitri YurandaAndalas University1
Puti Sri KomalaAffiliation unknown1
Arief AlmiAffiliation unknown1
Mimin Sundari NasutionRiau University1
Zaili RusliRiau University1
Almasdi SyahzaAffiliation unknown1
Dadang MashurRiau University1
Mayarni MayarniRiau University1
Fajriani AnandaAffiliation unknown1
Mersi Suriani SinagaUniversitas Sumatera Utara1
Rivaldi SidabutarUniversitas Sumatera Utara1
Sarah Patumona ManaluUniversitas Sumatera Utara1
Maicel Ria Debora SinagaUniversitas Sumatera Utara1
Ade Citra NadhiraUniversitas Sumatera Utara1
Dewi Sartika Br GintingUniversitas Sumatera Utara1
Ronald Leonardo SiregarUniversitas Sumatera Utara1
Fadhila FadhilaUniversitas Sumatera Utara1
Peer Mohamed AbdulNational University of Malaysia1
Sheylin Wimora Lumban TobingUniversitas Sumatera Utara1
Chindy Elsanna RevadiUniversitas Sumatera Utara1
Hendrik Voice SihombingUniversitas Sumatera Utara1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://jurnal.ar-raniry.ac.id/index.php/elkawnie/oai, first harvested 7 Nov 2026, last seen 16 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Effect of Electrode Distance, Stirring Speed and Contact Time on Removal of Polyethylene Microplastics (Microbeads) Using Electrocoagulation Method</dc:title>
	<dc:creator xml:lang="en">Fadhila, Fadhila</dc:creator>
	<dc:creator xml:lang="en">Zulkarnaini, Zulkarnaini</dc:creator>
	<dc:creator xml:lang="en">Husin, Amir</dc:creator>
	<dc:creator xml:lang="en">Syawal, Ferdy Ashari</dc:creator>
	<dc:subject xml:lang="en">Microbeads</dc:subject>
	<dc:subject xml:lang="en">Electrocoagulation</dc:subject>
	<dc:subject xml:lang="en">Electrolysis Time</dc:subject>
	<dc:description xml:lang="en">Abstract: Daily use of personal care products containing microbeads causes severe problems for the aquatic environment. Greywater is a pathway for microbeads to enter domestic waste and wastewater treatment plants (WWTPs) from personal care products. Their tiny size and hydrophobic nature allow microbeads to escape from WWTPs and end up in surface water. Therefore, processing efforts are needed to remove microbeads, one of which is using the electrocoagulation method with aluminum (Al) electrodes. This study aims to evaluate the performance of the electrocoagulation process using Al electrodes arranged in a monopolar configuration in a batch reactor to see the effect of variations in distance between electrodes of 1, 2.5, and 3.5 cm, stirring speed of 150, 200, and 250 rpm; with the contact time 60, 120, and 180 minutes in removing microbeads from artificial wastewater. This research shows that the best efficiency value of 99.30% occurs in operating conditions with a distance between electrodes of 2.5 cm, a stirring speed of 150 rpm, and a contact time of 180 minutes. ANOVA results showed that distance between electrodes, stirring speed, and contact time significantly affected microbead removal efficiency (p&amp;lt;0.05). The results of this research can be a reference for alternative tertiary processing at WWTPs.Abstrak: Penggunaan produk perawatan pribadi sehari-hari yang mengandung microbeads menyebabkan masalah serius bagi lingkungan perairan. Greywater merupakan jalur masuknya microbeads ke dalam limbah domestik dan instalasi pengolahan air limbah (IPAL) dari produk perawatan pribadi. Ukurannya yang sangat kecil dan sifat hidrofobiknya memungkinkan microbeads keluar dari IPAL dan berakhir ke air permukaan. Oleh karena itu diperlukan upaya pengolahan untuk menyisihkan microbeads, salah satunya dengan menggunakan metode elektrokoagulasi dengan elektroda aluminium (Al). Penelitian ini bertujuan untuk mengevaluasi kinerja proses elektrokoagulasi menggunakan elektroda Al yang disusun dalam konfigurasi monopolar dalam reaktor batch untuk melihat pengaruh variasi jarak antar elektroda 1, 2,5, dan 3,5 cm, kecepatan pengadukan 150, 200, dan 250 rpm, dan waktu kontak 60, 120, dan 180 menit dalam menyisihkan microbeads dari air limbah artifisial. Penelitian ini menunjukkan bahwa nilai efisiensi terbaik sebesar 99,30% terjadi pada kondisi operasi dengan jarak antar elektroda 2,5 cm, kecepatan pengadukan 150 rpm, dan waktu kontak 180 menit. Hasil ANOVA menunjukkan bahwa jarak antar elektroda, kecepatan pengadukan, dan waktu kontak berpengaruh signifikan terhadap efisiensi penyisihan microbead (p&amp;lt;0,05). Hasil penelitian ini dapat menjadi referensi alternatif pengolahan tersier di IPAL.</dc:description>
	<dc:publisher xml:lang="en">Faculty of Science and Technology Universitas Islam Negeri Ar-Raniry</dc:publisher>
	<dc:date>2024-06-22</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ar-raniry.ac.id/index.php/elkawnie/article/view/22195</dc:identifier>
	<dc:identifier>10.22373/ekw.v10i1.22195</dc:identifier>
	<dc:source xml:lang="en">Elkawnie; Vol. 10 No. 1 (2024); 158-168</dc:source>
	<dc:source>2460-8912</dc:source>
	<dc:source>2460-8920</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ar-raniry.ac.id/index.php/elkawnie/article/view/22195/pdf</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2024 Fadhila Fadhila, Zulkarnaini Zulkarnaini, Amir Husin, Ferdy Ashari Syawal</dc:rights>
</oai_dc:dc>