Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

HSPICE simulation and analysis of current reused operational transconductance amplifiers for biomedical applications

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 15 No. 1 (2025)

DOI
10.11591/ijece.v15i1.pp196-207
ISSN
2722-2578, 2088-8708
Published
2025-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The proposed work focuses on the design of a current-reused biomedical amplifier; it is a microwatt-level electrocardiogram (ECG) analog circuit design that addresses low power consumption and noise efficiency. As implantable devices require unobtrusiveness and longevity, the current reuse technique in this circuit effectively enhances power and noise efficiencies. Using 90 nm technology enables efficient circuit implementation, yielding promising simulation results. At 100 Hz, the noise performance reaches 62.095 nV/√Hz, while the power consumption is only 8.3797 µW. These advancements are pivotal for next-generation implantable devices, ensuring reliable operation and reducing frequent battery replacements, improving patient convenience. Moreover, the high noise efficiency ensures that ECG signals are captured with high fidelity, crucial for accurate monitoring and diagnosis. This research addresses the challenges in implantable ECG analog circuit design and sets a benchmark for future developments. The techniques employed can be adapted for other bio signal monitoring devices, broadening the impact on healthcare technology. Ultimately, this advancement contributes to more efficient, reliable, and long-lasting medical devices, enhancing patient monitoring and healthcare on a broader scale.

Collaboration network of the authors

3 authors · 3 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Koneru Lakshmaiah Education Foundation
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Swathi MummadiAffiliation unknown2

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>HSPICE simulation and analysis of current reused operational transconductance amplifiers for biomedical applications</dc:title><dc:creator>Chary, Udari Gnaneshwara</dc:creator><dc:creator>Kishore, Kakarla Hari</dc:creator><dc:description>&lt;jats:p&gt;The proposed work focuses on the design of a current-reused biomedical amplifier; it is a microwatt-level electrocardiogram (ECG) analog circuit design that addresses low power consumption and noise efficiency. As implantable devices require unobtrusiveness and longevity, the current reuse technique in this circuit effectively enhances power and noise efficiencies. Using 90 nm technology enables efficient circuit implementation, yielding promising simulation results. At 100 Hz, the noise performance reaches 62.095 nV/√Hz, while the power consumption is only 8.3797 µW. These advancements are pivotal for next-generation implantable devices, ensuring reliable operation and reducing frequent battery replacements, improving patient convenience. Moreover, the high noise efficiency ensures that ECG signals are captured with high fidelity, crucial for accurate monitoring and diagnosis. This research addresses the challenges in implantable ECG analog circuit design and sets a benchmark for future developments. The techniques employed can be adapted for other bio signal monitoring devices, broadening the impact on healthcare technology. Ultimately, this advancement contributes to more efficient, reliable, and long-lasting medical devices, enhancing patient monitoring and healthcare on a broader scale.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i1.pp196-207</dc:identifier><dc:identifier>10.11591/ijece.v15i1.pp196-207</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 1 (2025); 196</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/36214/17921</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>