Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Tilted fiber Bragg grating based optical sensor for simultaneous measurement of vital signs: a novel approach

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 15 No. 2 (2025)

DOI
10.11591/ijece.v15i2.pp1434-1445
ISSN
2722-2578, 2088-8708
Published
2025-04-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Vital signal monitoring acts as a highly significant diagnostic method. Continuous monitoring of vital signs like temperature, heart rate, and blood pressure aids in easy and fast disease diagnosis. Existing methods that enable continuous monitoring, such as smart watches, are not accurate enough to be used as a benchmark for diagnosing diseases. In this paper, we propose simultaneous temperature and heart rate measurement using tilted fiber Bragg grating (TFBG) which enables concurrent measurement of measurands due to its intrinsic optical property. Temperature and heart rate were considered for measurement. The proposed TFBG-based optical sensor has a sensitivity of 11.81 pm/°C and 1.73 pm/µε towards variation in temperature and strain, respectively. The sensitivity was determined by a shift in the wavelength of core mode resonance for temperature and a differential change in the wavelength of cladding mode resonance for heart rate. The average response time of the proposed TFBG sensor was found to be 3 seconds. Accuracy of 99.68% and 98.42% were achieved in temperature and heart rate measurements by the proposed TFBG sensor. The acceptability of the proposed TFBG sensor was analyzed using the Bland- Altman plot.

Collaboration network of the authors

3 authors · 3 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • SRM Institute of Science and Technology
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Tilted fiber Bragg grating based optical sensor for simultaneous measurement of vital signs: a novel approach</dc:title><dc:creator>Arumugam, Ramya</dc:creator><dc:creator>Kumar, Ramamoorthy</dc:creator><dc:creator>Dhanalakshmi, Samiappan</dc:creator><dc:description>&lt;jats:p&gt;Vital signal monitoring acts as a highly significant diagnostic method. Continuous monitoring of vital signs like temperature, heart rate, and blood pressure aids in easy and fast disease diagnosis. Existing methods that enable continuous monitoring, such as smart watches, are not accurate enough to be used as a benchmark for diagnosing diseases. In this paper, we propose simultaneous temperature and heart rate measurement using tilted fiber Bragg grating (TFBG) which enables concurrent measurement of measurands due to its intrinsic optical property. Temperature and heart rate were considered for measurement. The proposed TFBG-based optical sensor has a sensitivity of 11.81 pm/°C and 1.73 pm/µε towards variation in temperature and strain, respectively. The sensitivity was determined by a shift in the wavelength of core mode resonance for temperature and a differential change in the wavelength of cladding mode resonance for heart rate. The average response time of the proposed TFBG sensor was found to be 3 seconds. Accuracy of 99.68% and 98.42% were achieved in temperature and heart rate measurements by the proposed TFBG sensor. The acceptability of the proposed TFBG sensor was analyzed using the Bland- Altman plot.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i2.pp1434-1445</dc:identifier><dc:identifier>10.11591/ijece.v15i2.pp1434-1445</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 2 (2025); 1434</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/36914/18067</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>