Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Advanced stress detection with optimized feature selection and hybrid neural networks

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 15 No. 2 (2025)

DOI
10.11591/ijece.v15i2.pp1647-1655
ISSN
2722-2578, 2088-8708
Published
2025-04-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Stress impacts both mental and physical health, potentially leading to serious conditions like cardiovascular diseases and mental disorders. Early detection of stress is crucial for reducing these risks. This study aims to improve stress detection by analyzing physiological signals, specifically electroencephalography (EEG) and electrocardiogram (ECG). EEG is affordable, while ECG provides detailed insights into cardiovascular health. Feature selection is a major challenge in analyzing these signals. To address this, the research introduces a novel method that combines the Archimedes optimization algorithm (AoA) with the analytical hierarchical process (AHP) to enhance accuracy in both single and multimodal systems. The proposed multimodal system employs a parallel-structured convolutional neural network (CNN) with a deep architecture to extract spatial features and uses a long short-term memory (LSTM) network to capture temporal dynamics. Experimental results show significant improvements: ECG stress detection accuracy rises from 88.6% to 91.79%, EEG accuracy increases from 95% to 96.6%, and multimodal stress detection accuracy reaches 98.6%. These results highlight the effectiveness of the AoA-AHP-based feature selection technique in boosting stress detection accuracy, contributing to improved mental health management and overall well-being.

Collaboration network of the authors

2 authors · 1 co-authorship link

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Advanced stress detection with optimized feature selection and hybrid neural networks</dc:title><dc:creator>Patil, Sangita Ajit</dc:creator><dc:creator>Paithane, Ajay Namdeorao</dc:creator><dc:description>&lt;jats:p&gt;Stress impacts both mental and physical health, potentially leading to serious conditions like cardiovascular diseases and mental disorders. Early detection of stress is crucial for reducing these risks. This study aims to improve stress detection by analyzing physiological signals, specifically electroencephalography (EEG) and electrocardiogram (ECG). EEG is affordable, while ECG provides detailed insights into cardiovascular health. Feature selection is a major challenge in analyzing these signals. To address this, the research introduces a novel method that combines the Archimedes optimization algorithm (AoA) with the analytical hierarchical process (AHP) to enhance accuracy in both single and multimodal systems. The proposed multimodal system employs a parallel-structured convolutional neural network (CNN) with a deep architecture to extract spatial features and uses a long short-term memory (LSTM) network to capture temporal dynamics. Experimental results show significant improvements: ECG stress detection accuracy rises from 88.6% to 91.79%, EEG accuracy increases from 95% to 96.6%, and multimodal stress detection accuracy reaches 98.6%. These results highlight the effectiveness of the AoA-AHP-based feature selection technique in boosting stress detection accuracy, contributing to improved mental health management and overall well-being.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i2.pp1647-1655</dc:identifier><dc:identifier>10.11591/ijece.v15i2.pp1647-1655</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 2 (2025); 1647</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/37184/18087</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>