Abstract

Control equipment at substations requires a rectifier to convert alternative current (AC)-direct current (DC) electric current to provide DC power for relays, motors for disconnector switches and power breaker switches, and telecommunications equipment. Rectifiers have non-linear load characteristics, which can result in a waveform that is not pure sinusoidal due to the interaction of fundamental frequency sinusoidal waves with other waves known as harmonics. Therefore, to not interfere with the equipment's work, a filter is needed to reduce the harmonics produced by the rectifier. In this research, using MATLAB/Simulink, prevention was carried out using active filters, inductor-capacitor (LC), and inductor-capacitor-inductor (LCL) passive filters (Ta, Tc, and Td designs) separately. After the research was carried out, it was found that the amount of harmonics before installing the filter was 49.61%. Then, after installing the active filter, the harmonics were reduced to 0.29%, the installation of the passive LC filter was reduced to 9.29%, and the installation of the LCL filter (Ta, Tc, and Td) became 1.44%, 0.29%, and 1.44%.

Collaboration network of the authors

35 authors · 84 co-authorship links · 41 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Sumatera Utara
  • Universiti Teknologi MARA
  • Universitas Negeri Padang
  • King Mongkut's Institute of Technology Ladkrabang
  • Kanazawa University
  • University of Technology Malaysia
  • Yangon Technological University
  • Other organisations
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Muldi YuhendriUniversitas Negeri Padang3
Naemah MubarakahUniversitas Sumatera Utara2
Soeharwinto SoeharwintoUniversitas Sumatera Utara2
Issarachai NgamrooKing Mongkut's Institute of Technology Ladkrabang2
Farel SitumeangUniversitas Sumatera Utara2
Syahrun MubarokUniversitas Sumatera Utara2
Wahyu Franciscus SihotangUniversitas Sumatera Utara2
Dedet Candra RiawanInstitut Teknologi Sepuluh Nopember2
Daniel Julian SinagaUniversitas Sumatera Utara2
Timothy Juan Hartanto LumbanrajaUniversitas Sumatera Utara1
Yasunori TanakaKanazawa University1
Yanuar Zulardiansyah AriefUniversity of Technology Malaysia1
Maulaya MuhammadUniversitas Sumatera Utara1
Riswan DinziUniversitas Sumatera Utara1
Mai Kai Suan TialYangon Technological University1
Azrial Aziz Azhari NasutionUniversitas Sumatera Utara1
Muhammad Aulia DeskyMalikussaleh University1
Maksum PinemUniversitas Sumatera Utara1
Mohd Najib Mohd HussainUniversiti Teknologi MARA1
Faizzufar TaqyUniversitas Sumatera Utara1
Hafizh PrihtiadiState University of Malang1
Christian Kevin Imanuel SimarmataUniversitas Sumatera Utara1
Tomi Saputra Jaya TambunUniversitas Sumatera Utara1
Sihar Parlinggoman PanjaitanUniversitas Sumatera Utara1
Kasmir TanjungUniversitas Sumatera Utara1
Syiska YanaUniversitas Sumatera Utara1
Agus Kivander SaragiUniversitas Sumatera Utara1
Dadan RamdanMedan Area University1
Kerista TariganUniversitas Sumatera Utara1
Syahrul HumaidiUniversitas Sumatera Utara1
Erna FridaUniversitas Sumatera Utara1
M. A. AkbarUniversitas Sumatera Utara1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 15 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Comparative analysis of active filters, inductor-capacitor and inductor-capacitor-inductor passive filters in reducing harmonics</dc:title><dc:creator>Siregar, Yulianta</dc:creator><dc:creator>Azhari, Naomi</dc:creator><dc:creator>Mohamed, Nur Nabila</dc:creator><dc:description>&lt;jats:p&gt;Control equipment at substations requires a rectifier to convert alternative current (AC)-direct current (DC) electric current to provide DC power for relays, motors for disconnector switches and power breaker switches, and telecommunications equipment. Rectifiers have non-linear load characteristics, which can result in a waveform that is not pure sinusoidal due to the interaction of fundamental frequency sinusoidal waves with other waves known as harmonics. Therefore, to not interfere with the equipment's work, a filter is needed to reduce the harmonics produced by the rectifier. In this research, using MATLAB/Simulink, prevention was carried out using active filters, inductor-capacitor (LC), and inductor-capacitor-inductor (LCL) passive filters (Ta, Tc, and Td designs) separately. After the research was carried out, it was found that the amount of harmonics before installing the filter was 49.61%. Then, after installing the active filter, the harmonics were reduced to 0.29%, the installation of the passive LC filter was reduced to 9.29%, and the installation of the LCL filter (Ta, Tc, and Td) became 1.44%, 0.29%, and 1.44%.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i3.pp2567-2582</dc:identifier><dc:identifier>10.11591/ijece.v15i3.pp2567-2582</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 3 (2025); 2567</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/37090/18307</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>