Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Generalization of reactive power definition for periodical waveforms

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 16 No. 1 (2026)

DOI
10.11591/ijece.v16i1.pp102-110
ISSN
2722-2578, 2088-8708
Published
2026-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The article presents a selection of reactive power definitions, which are applicable for implementation in energy meters. For sinusoidal current and voltage waveforms, all provided dependencies yield equivalent reactive power values. However, in the presence of distorted current and voltage, the power values are determined by the applied method (algorithm). Standardization requirements for reactive energy meters stipulate metrological verification under sinusoidal conditions. The selection of an optimal reactive power definition remains a problematic and ongoing subject of debate within the field. The paper shows that a generalized unique definition of additive reactive power derives from the definition of active power. Unlike active power, reactive power must be independent of the conversion of electric energy into work and heat. This independence is achieved if one of the waveforms – the current in the scalar voltage and current product (specifying active power) – is replaced by a special orthogonal waveform. An orthogonal waveform can be derived through either differentiation or integration. Reactive power obtained by this method is an additive within the system. When differentiation is employed, the reactive power for a nonlinear resistive load with a unique, time-invariant current-voltage characteristic will be zero. Some other properties of reactive power defined in this way are presented. This method is straightforward to implement in reactive energy meters.

Collaboration network of the authors

2 authors · 1 co-authorship link

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Wrocław University of Science and Technology
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Generalization of reactive power definition for periodical waveforms</dc:title><dc:creator>Kosobudzki, Grzegorz</dc:creator><dc:creator>Ładniak, Leszek</dc:creator><dc:description>&lt;jats:p&gt;The article presents a selection of reactive power definitions, which are applicable for implementation in energy meters. For sinusoidal current and voltage waveforms, all provided dependencies yield equivalent reactive power values. However, in the presence of distorted current and voltage, the power values are determined by the applied method (algorithm). Standardization requirements for reactive energy meters stipulate metrological verification under sinusoidal conditions. The selection of an optimal reactive power definition remains a problematic and ongoing subject of debate within the field. The paper shows that a generalized unique definition of additive reactive power derives from the definition of active power. Unlike active power, reactive power must be independent of the conversion of electric energy into work and heat. This independence is achieved if one of the waveforms – the current in the scalar voltage and current product (specifying active power) – is replaced by a special orthogonal waveform. An orthogonal waveform can be derived through either differentiation or integration. Reactive power obtained by this method is an additive within the system. When differentiation is employed, the reactive power for a nonlinear resistive load with a unique, time-invariant current-voltage characteristic will be zero. Some other properties of reactive power defined in this way are presented. This method is straightforward to implement in reactive energy meters.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2026-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v16i1.pp102-110</dc:identifier><dc:identifier>10.11591/ijece.v16i1.pp102-110</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 16 No 1 (2026); 102</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/40216/18613</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>