Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Exploring the Effect of Different Scanning Protocols on the Modulation Transfer Function

Atom Indonesia · Vol. 51 No. 2 (2025) · pp. 165–171

DOI
10.55981/aij.2025.1553
ISSN
2356-5322, 0126-1568
Published
2025-07-23
Publisher
National Research and Innovation Agency
Language
eng
License
creativecommons.org/licenses/by-nc-sa/4.0

Abstract

The Iterative Reconstruction (IR) algorithm can enhance image quality and reduce patient dose. This study aims to evaluate the in-plane resolution (X- and Y-), in association with different IR and filtered back projection (FBP), on three different Computed Tomography (CT) scanners: General Electric (GE), Philips, and Siemens. Uniform water phantoms were scanned using 35 milligrays (mGy) and 65 (mGy and then reconstructed using 2- and 5-millimetre (mm) slice thicknesses. Images were reconstructed using the iterative Beam Hardening Correction (iBHC), Sinogram-Affirmed Iterative Reconstruction (SAFIRE), 4th generation hybrid statistical iterative reconstruction proposed by philips (iDose4), Filtered Back Projection (FBP), Adaptive Statistical iterative Reconstruction (ASiR-V), Weighted Filtered Back Projection (WFBP), Best Contrast or Brain Contrast algorithm (BC). All images were analysed using IndoQCT software. Automated Modulation Transfer Function (MTF) measurement was used to describe in-plane resolution. From the Siemens CT scanner findings, MTF at 10 % (MTF10) was increased by applying the iBHC algorithm from 0.52 to 0.57, but MTF10 of SAFIRE and WFBP showed no difference. For the Philips CT scanner, the iDose4 technique did not affect MTF10 compared to FBP, while the post-processing by BC decreases MTF10 from 0.5 to 0.49. For the GE CT scanner, the MTF is affected by radiation dose, while the ASiR-V MTF curve had no difference compared to FBP, with the highest MTF10 value of 0.67 for 35 mGy protocol compared to 0.64 for 65 mGy protocol. The image resolution is affected by CT dose and the use of reconstruction algorithms. These associated parameters may enhance or reduce image resolution.

Keywords

Collaboration network of the authors

40 authors · 115 co-authorship links · 72 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Diponegoro University
  • Universiti Sains Malaysia
  • Bandung Institute of Technology
  • University of Indonesia
  • Pertamina (Indonesia)
  • Ministry of Health
  • Rumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Geoff DoughertyCalifornia State University, Channel Islands5
Ariij NaufalDiponegoro University3
Freddy HaryantoBandung Institute of Technology2
Annisa Lidia WatiDiponegoro University2
Arrum NitasariDiponegoro University2
S SyarifudinDr. Kariadi Hospital2
Mohd Hanafi AliLincoln University College2
N.D. OsmanUniversiti Sains Malaysia2
Choirul AnamDiponegoro University2
M. E. AzizUniversiti Sains Malaysia2
N.P. ViantriDiponegoro University1
Wahyu SetiabudiDiponegoro University1
F. NadzirPertamina (Indonesia)1
Chavied VarunaPertamina (Indonesia)1
Rena WiditaBandung Institute of Technology1
Idam ArifBandung Institute of Technology1
Mohamad Fahdillah RhaniTan Tock Seng Hospital1
S. YaniIPB University1
S. SofiyatunDiponegoro University1
Ummu Mar'atu ZahroDiponegoro University1
Dito Andi RukmanaAffiliation unknown1
M. T. SaidinMinistry of Health1
Azhar Abdul RahmanUniversiti Sains Malaysia1
Hanif Haspi HarunMinistry of Health1
Yasmin Md RadziUniversiti Sains Malaysia1
Zunaide KayunGovernment of Malaysia1
Titi AmaliaUniversity of Indonesia1
Benny ZulkarnaienUniversity of Indonesia1
K. NurcahyoUniversity of Indonesia1
H. TussyadiahRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
D. E. PradanaRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Wahyu Setia BudiDiponegoro University1
Eko HidayantoDiponegoro University1
Dewi Angraini InsianoDiponegoro University1
Annisa Tenri MayaAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Exploring the Effect of Different Scanning Protocols on the Modulation Transfer Function</dc:title>
	<dc:creator>Arjah, H.</dc:creator>
	<dc:creator>Osman, N. D.</dc:creator>
	<dc:creator>ALMasri, H.</dc:creator>
	<dc:creator>Anam, C.</dc:creator>
	<dc:creator>Aziz, M. E.</dc:creator>
	<dc:subject xml:lang="en-US">Computed tomography, MTF, Iterative reconstruction</dc:subject>
	<dc:description xml:lang="en-US">The Iterative Reconstruction (IR) algorithm can enhance image quality and reduce patient dose. This study aims to evaluate the in-plane resolution (X- and Y-), in association with different IR and filtered back projection (FBP), on three different Computed Tomography (CT) scanners: General Electric (GE), Philips, and Siemens. Uniform water phantoms were scanned using 35 milligrays (mGy) and 65 (mGy and then reconstructed using 2- and 5-millimetre (mm) slice thicknesses. Images were reconstructed using the iterative Beam Hardening Correction (iBHC), Sinogram-Affirmed Iterative Reconstruction (SAFIRE), 4th generation hybrid statistical iterative reconstruction proposed by philips (iDose4), Filtered Back Projection (FBP), Adaptive Statistical iterative Reconstruction (ASiR-V), Weighted Filtered Back Projection (WFBP), Best Contrast or Brain Contrast algorithm (BC). All images were analysed using IndoQCT software. Automated Modulation Transfer Function (MTF) measurement was used to describe in-plane resolution. From the Siemens CT scanner findings, MTF at 10 % (MTF10) was increased by applying the  iBHC algorithm from 0.52 to 0.57, but MTF10 of SAFIRE and WFBP    showed no difference. For the Philips CT scanner, the iDose4 technique did not affect MTF10 compared to FBP, while the post-processing by BC decreases MTF10 from 0.5 to 0.49. For the GE CT scanner, the MTF is affected by radiation dose, while the ASiR-V MTF curve had no difference compared to FBP, with the highest MTF10 value of 0.67 for 35 mGy protocol compared to 0.64 for 65 mGy protocol. The image resolution is affected by CT dose and the use of reconstruction algorithms. These associated parameters may enhance or reduce image resolution.</dc:description>
	<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-07-23</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/1553</dc:identifier>
	<dc:identifier>10.55981/aij.2025.1553</dc:identifier>
	<dc:source xml:lang="en-US">Atom Indonesia; Vol 51, No 2 (2025): AUGUST 2025; 165-171</dc:source>
	<dc:source>2356-5322</dc:source>
	<dc:source>0126-1568</dc:source>
	<dc:source>10.55981/aij.v51i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/1553/1177</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1553/2731</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1553/2749</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1553/2750</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1553/2751</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1553/2752</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1553/2753</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Atom Indonesia</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>