Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Comparative Assessment of Radioactive Contamination in APR 1400 Reactor During SBO and TMI Accidents

Atom Indonesia · Vol. 52 No. 1 (2026) · pp. 43–48

DOI
10.55981/aij.2026.1558
ISSN
2356-5322, 0126-1568
Published
2026-03-12
Publisher
National Research and Innovation Agency
Language
eng
License
creativecommons.org/licenses/by-nc-sa/4.0

Abstract

An alternative approach to estimate the tissue phantom ratio (TPR) at depths of 20 cm and 10 cm (TPR₂₀,₁₀) under non-reference conditions is required to address situations where a 10 × 10 cm² field size is not achievable on a specific linear accelerator (LINAC) during a beam quality test. This study aims to estimate the TPR20,10 under non-reference conditions using a geometric sequence approach, and to compare it with the TPR₂₀,₁₀ under non-reference conditions estimated using the Sauer method, the Palmas method, a linear fit approach, as well as with the TPR₂₀,₁₀ under reference conditions calculated using the TRS-398 protocol. The first step in this study was measuring the percentage depth dose (PDD), D20cm, and D10cm with field size variations from 4 × 4 cm² to 10 × 10 cm² for both 6 MV and 10 MV X-ray beams. The PDD were used to estimate the TPR₂₀,₁₀ using a geometric sequence approach, the Sauer method, the Palmans method, and a linear fit approach, and to calculate the TPR₂₀,₁₀ using the TRS-398 protocol. The D20 cm and D10 cm were also used to calculate the TPR₂₀,₁₀ using the TRS-398 protocol. The TPR₂₀,₁₀ for 6 MV and 10 MV X-ray beams estimated using the geometric sequence approach were 0.683 ± 0.004 and 0.742 ± 0.005, respectively. The level of precision that could be reached by the geometric sequence approach is potentially equivalent to the TRS-398 protocol, the Sauer method, the Palmans method, and the linear fit approach. The TPR₂₀,₁₀ for 6 MV and 10 MV X-ray beams estimated using the geometric sequence method did not show a significant difference compared with the TPR₂₀,₁₀ calculated using the TRS-398 protocol. However, the TPR₂₀,₁₀ for 6 MV and 10 MV X-ray beams estimated using the geometric sequence approach showed a significant difference compared with those TPR₂₀,₁₀ estimated using the Sauer method and the Palmans method.

Keywords

Collaboration network of the authors

8 authors · 14 co-authorship links · 8 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Nuclear Science and Technology Research Institute
  • Islamic Azad University, Science and Research Branch
  • Islamic Azad University Central Tehran Branch
  • Sirjan University of Technology
  • Islamic Azad University, Aliabad Katoul
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
F. S. DauriaAffiliation unknown2
Jalil JafariNuclear Science and Technology Research Institute2
Abbas ZeighamiIslamic Azad University Central Tehran Branch1
Masoud KhaleghiSirjan University of Technology1
Mehdi Hashemi-TilehnoeeIslamic Azad University, Aliabad Katoul1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, first harvested 8 Nov 2026, last seen 16 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Comparative Assessment of Radioactive Contamination in APR 1400 Reactor During SBO and TMI Accidents</dc:title>
	<dc:creator>Ghaderinia, F.</dc:creator>
	<dc:creator>Rahgoshay, M.</dc:creator>
	<dc:creator>Jafari, J.</dc:creator>
	<dc:subject xml:lang="en-US">Severe accident; APR 1400; Radiological contamination; Station blackout, Containment failure</dc:subject>
	<dc:description xml:lang="en-US">An alternative approach to estimate the tissue phantom ratio (TPR) at depths of 20 cm and 10 cm (TPR₂₀,₁₀) under non-reference conditions is required to address situations where a 10 × 10 cm² field size is not achievable on a specific linear accelerator (LINAC) during a beam quality test. This study aims to estimate the TPR20,10 under non-reference conditions using a geometric sequence approach, and to compare it with the TPR₂₀,₁₀ under non-reference conditions estimated using the Sauer method, the Palmas method, a linear fit approach, as well as with the TPR₂₀,₁₀ under reference conditions calculated using the TRS-398 protocol. The first step in this study was measuring the percentage depth dose (PDD), D20cm, and D10cm with field size variations from 4 × 4 cm² to 10 × 10 cm² for both 6 MV and 10 MV X-ray beams. The PDD were used to estimate the TPR₂₀,₁₀ using a geometric sequence approach, the Sauer method, the Palmans method, and a linear fit approach, and to calculate the TPR₂₀,₁₀ using the TRS-398 protocol. The D20 cm and D10 cm were also used to calculate the TPR₂₀,₁₀ using the TRS-398 protocol. The TPR₂₀,₁₀ for 6 MV and 10 MV X-ray beams estimated using the geometric sequence approach were 0.683 ± 0.004 and 0.742 ± 0.005, respectively. The level of precision that could be reached by the geometric sequence approach is potentially equivalent to the TRS-398 protocol, the Sauer method, the Palmans method, and the linear fit approach. The TPR₂₀,₁₀ for 6 MV and 10 MV X-ray beams estimated using the geometric sequence method did not show a significant difference compared with the TPR₂₀,₁₀ calculated using the TRS-398 protocol. However, the TPR₂₀,₁₀ for 6 MV and 10 MV X-ray beams estimated using the geometric sequence approach showed a significant difference compared with those TPR₂₀,₁₀ estimated using the Sauer method and the Palmans method.</dc:description>
	<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-03-12</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/1558</dc:identifier>
	<dc:identifier>10.55981/aij.2026.1558</dc:identifier>
	<dc:source xml:lang="en-US">Atom Indonesia; Vol 52, No 1 (2026): APRIL 2026; 43-48</dc:source>
	<dc:source>2356-5322</dc:source>
	<dc:source>0126-1568</dc:source>
	<dc:source>10.55981/aij.v52i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/1558/1207</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1558/2918</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1558/2919</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1558/2920</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1558/2921</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Atom Indonesia</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>