Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Preliminary Study on Mass Flow Rate in Passive Cooling Experimental Simulation During Transient Using NC-Queen Apparatus

Atom Indonesia · Vol. 40 No. 3 (2015) · pp. 141–147

DOI
10.17146/aij.2014.333
ISSN
2356-5322, 0126-1568
Published
2015-03-03
Publisher
National Research and Innovation Agency
Language
eng
License
creativecommons.org/licenses/by-nc-sa/4.0

Abstract

The research related to thermal management has been significantly inreased, especially for NPP safety. The use of passive cooling systems both during the accident and operation become reliable in the advanced reactor safety systems. Therefore it should be enhanced through experimental studies to investigate heat transfer phenomenon of the heat decay in transient cooling condition.An investigation has been performed through experiment using an NC-Queen apparatusconstructed with rectangular loop. Piping were consisting of tubes of SS316L with diameter, length, and width of 3/4 inch, 2.7 m, and 0.5 m respectively. The height between heater and cooler was 1.4 m. The experiment used initial water temperature at 70oC, 80oC, and 90oC in heater area. Transient temperature was used as experimental data to calculate water mass flow rate. The results showed that the temperature in heater area and cooler area were decreasing of about 90.6% and 95.7% at initial temperatur of 80oC, and of about 71.1% and 59.4% at initial temperature of 70oC. Those results were at higher initial temperature of 90oC compared with the initial temperature of 90oC. The average of water mass flow rate increased 81.03% from initial temperatur of 70oC. It was shown that the averages of removed heat in every second from water due to heat loss and cooler,were 3.51 watts, 5.06 watts and 6.85 watts respectively. The initial condition of heat stored in the water was quite different, but to the cooler heat removal capacity and heat loss was almost the same.Received: 10 November 2014; Revised: 23 December 2014: 24 December 2014

Keywords

Collaboration network of the authors

40 authors · 114 co-authorship links · 30 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • National Nuclear Energy Agency of Indonesia
  • National Research and Innovation Agency
  • Universitas Gadjah Mada
  • University of Indonesia
  • Bandung Institute of Technology
  • University of Technology Sydney
  • Udayana University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Anhar Riza AntariksawanNational Nuclear Energy Agency of Indonesia4
N. PutraAffiliation unknown3
Putut Hery SetiawanNational Research and Innovation Agency3
Sri IsmarwantiNational Nuclear Energy Agency of Indonesia3
Mukhsinun Hadi KusumaNational Nuclear Energy Agency of Indonesia3
Tanti ArdiyatiNational Nuclear Energy Agency of Indonesia3
T.M.I. MahliaUniversity of Technology Sydney3
Deendarlianto DeendarliantoUniversitas Gadjah Mada2
Arif Adtyas BudimanNational Research and Innovation Agency2
D. HaryantoNational Nuclear Energy Agency of Indonesia2
J.P. WitokoNational Nuclear Energy Agency of Indonesia2
GI GiarnoNational Nuclear Energy Agency of Indonesia2
Dwi IrwantoBandung Institute of Technology1
Zuhair ZuhairNational Nuclear Energy Agency of Indonesia1
D.T. Sony TjahyaniNational Nuclear Energy Agency of Indonesia1
Ainur RosidiNational Nuclear Energy Agency of Indonesia1
Wayan Nata SeptiadiUdayana University1
Irwin Pratama PutraUniversity of Indonesia1
Ranggi SahmuraUniversity of Indonesia1
Pande Made UdiyaniNational Nuclear Energy Agency of Indonesia1
Sri KuntjoroNational Nuclear Energy Agency of Indonesia1
W. LuthfiAffiliation unknown1
Zaki Su’udBandung Institute of Technology1
P W JokoNational Nuclear Energy Agency of Indonesia1
H IsmuNational Nuclear Energy Agency of Indonesia1
Edy SNational Nuclear Energy Agency of Indonesia1
Kiswanta KiswantaNational Nuclear Energy Agency of Indonesia1
Akhmad Muktaf HaifaniNational Research and Innovation Agency1
W. PrakosoUniversity of Indonesia1
Hadi SuntokoNational Research and Innovation Agency1
A. G. MuhammadNational Research and Innovation Agency1
RA. KoestoerAffiliation unknown1
Indarto IndartoUniversitas Gadjah Mada1
Sinta Tri HabsariAffiliation unknown1
E. P. AristaUniversitas Gadjah Mada1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, first harvested 8 Nov 2026, last seen 8 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Preliminary Study on Mass Flow Rate in Passive Cooling Experimental Simulation During Transient Using NC-Queen Apparatus</dc:title>
	<dc:creator>Juarsa, M.</dc:creator>
	<dc:creator>Purba, J.H.</dc:creator>
	<dc:creator>Kusuma, H.M.</dc:creator>
	<dc:creator>Setiadipura, T.</dc:creator>
	<dc:creator>Widodo, S.</dc:creator>
	<dc:subject xml:lang="en-US">Flow; Passive; Temperature; Transient; Decay</dc:subject>
	<dc:description xml:lang="en-US">The research related to thermal management has been significantly inreased, especially for NPP safety. The use of passive cooling systems both during the accident and operation become reliable in the advanced reactor safety systems. Therefore it should be enhanced through experimental studies to investigate heat transfer phenomenon of the heat decay in transient cooling condition.An investigation has been performed through experiment using an NC-Queen apparatusconstructed with rectangular loop. Piping were consisting of tubes of SS316L with diameter, length, and width of 3/4 inch, 2.7 m, and 0.5 m respectively. The height between heater and cooler was 1.4 m. The experiment used initial water temperature  at 70oC, 80oC, and 90oC in heater area. Transient temperature was used as experimental data to calculate water mass flow rate. The results showed that the temperature in heater area and cooler area were decreasing of about 90.6% and 95.7% at initial temperatur of 80oC, and of about 71.1% and 59.4% at initial temperature of 70oC. Those results were at higher initial temperature of 90oC compared with the initial temperature of 90oC. The average of water mass flow rate increased 81.03% from initial temperatur of 70oC. It was shown that the averages of removed heat in every second from water due to heat loss and cooler,were 3.51 watts, 5.06 watts and 6.85 watts respectively. The initial condition of heat stored in the water was quite different, but to the cooler heat removal capacity and heat loss was almost the same.Received: 10 November 2014; Revised: 23 December 2014: 24 December 2014</dc:description>
	<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
	<dc:contributor xml:lang="en-US">National Nuclear Energy Agency</dc:contributor>
	<dc:date>2015-03-03</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/333</dc:identifier>
	<dc:identifier>10.17146/aij.2014.333</dc:identifier>
	<dc:source xml:lang="en-US">Atom Indonesia; Vol 40, No 3 (2014): December 2014; 141-147</dc:source>
	<dc:source>2356-5322</dc:source>
	<dc:source>0126-1568</dc:source>
	<dc:source>10.17146/aij.2014.%x</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/333/336</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/333/71</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/333/191</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/333/192</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/333/193</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2016 Atom Indonesia</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>