Melola Discovery

← Melola Discovery

Journal SINTA 1

Accuracy and Stability Trade-off in RSSI Window Aggregation for MLP-Based Wi-Fi Indoor Positioning

Indonesian Journal of Electical Engineering and Informatics (IJEEI) · Vol. 14 No. 3 (2026) · pp. 861–873

DOI
10.52549/ijeei.v14i3.8256
ISSN
2089-3272, 2089-3272
Published
2026-09-30
Publisher
IAES Indonesian Section
Language
en

Abstract

Wi-Fi RSSI fingerprinting is practical for indoor positioning, but short-term signal fluctuations can reduce classification consistency. This study evaluates how fixed RSSI window size affects the accuracy, stability, and sample availability of an MLP-based indoor positioning system. RSSI from three Access Points was collected at 45 ordered corridor positions. Non-overlapping windows with n=1,3,5,7,9,11,15,21 and 29 were represented by the mean and standard deviation of three RSSI channels. The MLP was assessed using stratified 5-fold cross-validation with supplementary order-blocked validation. Relative to the n=1 baseline Accuracy of 68.24%, n=7 achieved 90.60 ± 0.71% Accuracy, 95.08 ± 1.31% Top-2 Accuracy, 0.9047 ± 0.0060 Macro-F1, and 0.4319 ± 0.1364 Ordinal Error. Larger windows achieved higher mean Accuracy but sharply reduced window-level samples and increased fold-to-fold variability. Order-blocked validation produced more conservative estimates and shifted the strongest performance region toward n=9 to n=11. These findings show that fixed-window selection should consider predictive performance, evaluation stability, sample availability, and validation design rather than maximum Accuracy alone.

Keywords

Collaboration network of the authors

7 authors · 13 co-authorship links · 2 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Malaysia Perlis
  • Universitas Muhammadiyah Parepare
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Amir Nazren Abdul RahimUniversiti Malaysia Perlis1
Lee Yeng SengUniversiti Malaysia Perlis1
Mohd Wafi NasrudinUniversiti Malaysia Perlis1
Iszaidy IsmailUniversiti Malaysia Perlis1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://section.iaesonline.com/index.php/IJEEI/oai, first harvested 8 Nov 2026, last seen 8 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Accuracy and Stability Trade-off in RSSI Window Aggregation for MLP-Based Wi-Fi Indoor Positioning</dc:title>
	<dc:creator xml:lang="en">Arthanugraha, Wahyu</dc:creator>
	<dc:creator xml:lang="en">Ismail, Abdul Halim</dc:creator>
	<dc:creator xml:lang="en">Yaakob, Shahrul Nizam</dc:creator>
	<dc:subject xml:lang="en">Wi-Fi indoor positioning</dc:subject>
	<dc:subject xml:lang="en">RSSI window aggregation</dc:subject>
	<dc:subject xml:lang="en">multilayer perceptron</dc:subject>
	<dc:subject xml:lang="en">fingerprinting</dc:subject>
	<dc:subject xml:lang="en">accuracy and stability trade-off</dc:subject>
	<dc:description xml:lang="en">Wi-Fi RSSI fingerprinting is practical for indoor positioning, but short-term signal fluctuations can reduce classification consistency. This study evaluates how fixed RSSI window size affects the accuracy, stability, and sample availability of an MLP-based indoor positioning system. RSSI from three Access Points was collected at 45 ordered corridor positions. Non-overlapping windows with n=1,3,5,7,9,11,15,21 and 29 were represented by the mean and standard deviation of three RSSI channels. The MLP was assessed using stratified 5-fold cross-validation with supplementary order-blocked validation. Relative to the n=1 baseline Accuracy of 68.24%, n=7 achieved 90.60 ± 0.71% Accuracy, 95.08 ± 1.31% Top-2 Accuracy, 0.9047 ± 0.0060 Macro-F1, and 0.4319 ± 0.1364 Ordinal Error. Larger windows achieved higher mean Accuracy but sharply reduced window-level samples and increased fold-to-fold variability. Order-blocked validation produced more conservative estimates and shifted the strongest performance region toward n=9 to n=11. These findings show that fixed-window selection should consider predictive performance, evaluation stability, sample availability, and validation design rather than maximum Accuracy alone.</dc:description>
	<dc:publisher xml:lang="en">IAES Indonesian Section</dc:publisher>
	<dc:date>2026-09-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://section.iaesonline.com/index.php/IJEEI/article/view/8256</dc:identifier>
	<dc:identifier>10.52549/ijeei.v14i3.8256</dc:identifier>
	<dc:source xml:lang="en">Indonesian Journal of Electrical Engineering and Informatics (IJEEI); Vol. 14 No. 3: September 2026; 861-873</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:source>2089-3272</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://section.iaesonline.com/index.php/IJEEI/article/view/8256/1110</dc:relation>
</oai_dc:dc>