Abstract

Voltage instability has been considered as a major threat to power system networks since last three decades. Frequent incidences of grid failures caused by voltage instability have been observed in different parts of the world. Fast voltage stability assessment of power system may be done by formation of voltage control areas, clubbing group of buses in geographically compact region having similar voltage instability problem. This paper presents a new approach for formation of voltage control areas (VCAs) based on sensitivity of reactive power generations with respect to reactive power demands, together with bus voltage variations under voltage stability based critical contingencies. The load buses in geographically compact region showing similar sensitivity of reactive power demand to reactive generations have been clubbed together to form voltage control areas. Since, voltage control areas formed should remain valid under change in operating conditions and network topology, the areas formed based on reactive power sensitivitieshave been modified considering voltage variations at different loadings points under voltage stability based critical contingencies. Voltage stability based Critical contingencies have been selected based on maximum loadability criterion. Case studies have been performed on IEEE 14-bus system. Simulation results performed on IEEE 14-bus system validate VCAs formed even under change in network topology caused by line outages and change in operating conditions caused by variations in real and reactive power demands. The VCAs formed by proposed method have been compared with VCAs formed by few existing approaches. The superiority of proposed approach of voltage control areas formation over few existing approaches has been established on the test system considered.

Keywords

Collaboration network of the authors

5 authors · 7 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Brijesh SinghAffiliation unknown1
D.K. TantiAffiliation unknown1
O.N. MehrotraAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Voltage Stability Based Formation of Voltage Control Areas Considering Impact of Contingencies</dc:title>
	<dc:creator>Martolia, Tarun</dc:creator>
	<dc:creator>Verma, M.K.</dc:creator>
	<dc:subject xml:lang="en-US">Voltage control area,  reactive power sensitivity, contingencies, maximum loadability, voltage stability</dc:subject>
	<dc:description xml:lang="en-US">Voltage instability has been considered as a major threat to power system networks since last three decades. Frequent incidences of grid failures caused by voltage instability have been observed in different parts of the world. Fast voltage stability assessment of power system may be done by formation of voltage control areas, clubbing group of buses in geographically compact region having similar voltage instability problem. This paper presents a new approach for formation of voltage control areas (VCAs) based on sensitivity of reactive power generations with respect to reactive power demands, together with bus voltage variations under voltage stability based critical contingencies. The load buses in geographically compact region showing similar sensitivity of reactive power demand to reactive generations have been clubbed together to form voltage control areas. Since, voltage control areas formed should remain valid under change in operating conditions and network topology, the areas formed based on reactive power sensitivitieshave been modified considering voltage variations at different loadings points under voltage stability based critical contingencies. Voltage stability based Critical contingencies have been selected based on maximum loadability criterion. Case studies have been performed on IEEE 14-bus system. Simulation results performed on IEEE 14-bus system validate VCAs formed even under change in network topology caused by line outages and change in operating conditions caused by variations in real and reactive power demands. The VCAs formed by proposed method have been compared with VCAs formed by few existing approaches. The superiority of proposed approach of voltage control areas formation over few existing approaches has been established on the test system considered.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2012-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/1291</dc:identifier>
	<dc:identifier>10.11591/ijape.v1.i3.pp115-122</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 1, No 3: December 2012; 115-122</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v1.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/1291/735</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>