Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Fault diagnosis of electric motors using vibration signal analysis

International Journal of Applied Power Engineering (IJAPE) · Vol. 14 No. 2 (2025) · pp. 300–307

DOI
10.11591/ijape.v14.i2.pp300-307
ISSN
2722-2624, 2252-8792
Published
2025-06-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

In industrial applications, especially in manufacturing environments, electric motors are employed practically everywhere. They are necessary for many different sectors, which can sometimes make it challenging to prevent malfunctions and keep them operating at their best. Numerous defects can affect how well they work, but bearing-related errors are the most frequent reasons for motor failures. This research uses temporal and frequency domain analysis of vibration signals to identify motor faults. A public domain database has been used for the investigation and analysis. The findings show that electric motor problems, including inner raceway, outer raceway, and rolling element fault, can be identified and diagnosed using the time and frequency domain features extracted from the vibration signals. The effectiveness of the proposed technique is shown by comparing it with both the time domain and frequency domain techniques. The accuracy of the time domain and frequency domain techniques is 85.4% and 91.6% respectively. However, the proposed hybrid technique has a far better accuracy of 95.8% as compared to the two techniques.

Keywords

Collaboration network of the authors

4 authors · 4 co-authorship links · 3 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Punjab Engineering College
  • Thapar Institute of Engineering & Technology
  • Guru Nanak Dev University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Kavita DhamiPunjab Engineering College1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Fault diagnosis of electric motors using vibration signal analysis</dc:title>
	<dc:creator>Singh, Mandeep</dc:creator>
	<dc:creator>Saggu, Tejinder Singh</dc:creator>
	<dc:creator>Dhingra, Arvind</dc:creator>
	<dc:subject xml:lang="en-US">bearing faults; electric motors; frequency domain analysis; time domain analysis; vibration signals</dc:subject>
	<dc:description xml:lang="en-US">In industrial applications, especially in manufacturing environments, electric motors are employed practically everywhere. They are necessary for many different sectors, which can sometimes make it challenging to prevent malfunctions and keep them operating at their best. Numerous defects can affect how well they work, but bearing-related errors are the most frequent reasons for motor failures. This research uses temporal and frequency domain analysis of vibration signals to identify motor faults. A public domain database has been used for the investigation and analysis. The findings show that electric motor problems, including inner raceway, outer raceway, and rolling element fault, can be identified and diagnosed using the time and frequency domain features extracted from the vibration signals. The effectiveness of the proposed technique is shown by comparing it with both the time domain and frequency domain techniques. The accuracy of the time domain and frequency domain techniques is 85.4% and 91.6% respectively. However, the proposed hybrid technique has a far better accuracy of 95.8% as compared to the two techniques.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21188</dc:identifier>
	<dc:identifier>10.11591/ijape.v14.i2.pp300-307</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 14, No 2: June 2025; 300-307</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v14.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21188/13311</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Tejinder Singh</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>