Open access
Journal
SINTA 1
Load Flow Analysis for Process – Tank Loading Power Generation Networks Interconnection
International Journal of Applied Power Engineering (IJAPE) · Vol. 3 No. 1 (2014) · pp. 9–14
ISSN 2722-2624, 2252-8792
Published 2014-04-01
Publisher Institute of Advanced Engineering and Science
Language eng
Abstract
Establishment of interconnection links between Process -Tank Loading electrical networks bring some advantages as there are excess capacity at Process which can be utilized in principle to feed Tank Loading. Some result of power system study will be as an input for operational purposes. Concerning Motor Starting Studies and Load Flow Studies and taking into account that the transformer is off load tap changing, the best tapping position for Isolation Transformer is at -5% (primary side). The best technical power generation configuration is proposed with configuration 2 (two) Process -TEG and 1 (one) Tank Loading-TEG running with 2 (two) interconnection, provided with appropriate load shedding system. Bare in mind that during smooth power transfer from each Process-TEG which requires 3 (three) Process-TEG running in parallel, there is an issue on kA capacity of Process switchgear. Existing setting of protection relay shall be reviewed according to the result of protection coordination study
Collaboration network of the authors
No co-authors found in Melola yet.
Metadata source: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Load Flow Analysis for Process – Tank Loading Power Generation Networks Interconnection</dc:title>
<dc:creator>Arindya, Radita</dc:creator>
<dc:subject xml:lang="en-US">LOAD FLOW ANALYSIS ; POWER GENERATION NETWORKS INTERCONNECTION</dc:subject>
<dc:description xml:lang="en-US">Establishment of interconnection links between Process -Tank Loading electrical networks bring some advantages as there are excess capacity at Process which can be utilized in principle to feed Tank Loading. Some result of power system study will be as an input for operational purposes. Concerning Motor Starting Studies and Load Flow Studies and taking into account that the transformer is off load tap changing, the best tapping position for Isolation Transformer is at -5% (primary side). The best technical power generation configuration is proposed with configuration 2 (two) Process -TEG and 1 (one) Tank Loading-TEG running with 2 (two) interconnection, provided with appropriate load shedding system. Bare in mind that during smooth power transfer from each Process-TEG which requires 3 (three) Process-TEG running in parallel, there is an issue on kA capacity of Process switchgear. Existing setting of protection relay shall be reviewed according to the result of protection coordination study</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2014-04-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/1317</dc:identifier>
<dc:identifier>10.11591/ijape.v3.i1.pp9-14</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 3, No 1: April 2014; 9-14</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v3.i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/1317/755</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via DOI
1 citation
Crossref
Not found
Counts as reported by each index on 13 Nov 2026; indexes count citations differently.
Cite this article
APA 7
Arindya, R. (2014). Load Flow Analysis for Process – Tank Loading Power Generation Networks Interconnection. International Journal of Applied Power Engineering (IJAPE), 3(1), 9–14. https://doi.org/10.11591/ijape.v3.i1.pp9-14
Copy
IEEE
R. Arindya, “Load Flow Analysis for Process – Tank Loading Power Generation Networks Interconnection,” International Journal of Applied Power Engineering (IJAPE), vol. 3, no. 1, pp. 9–14, 2014, doi: 10.11591/ijape.v3.i1.pp9-14.
Copy
Generated from the journal's metadata; check author names before use.