Assessing transformer health through analysis of dissolved gases in cooling oil

International Journal of Applied Power Engineering (IJAPE) · Vol. 13 No. 4 (2024) · pp. 1014–1020

DOI
10.11591/ijape.v13.i4.pp1014-1020
ISSN
2722-2624, 2252-8792
Published
2024-12-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Gases can form within the insulation system for various reasons while a transformer is in operation. If these gases are not promptly and properly managed, they can negatively impact the transformer's performance. Using the dissolved gas analysis (DGA) method to identify and assess the type and quantity of dissolved gases in transformer oil can uncover potential issues within the transformer. This information is crucial for guiding preventive maintenance and necessary repairs. Dissolved gas analysis testing was conducted by extracting transformer oil samples to identify signs of disturbances in the transformer based on the dissolved gas content. This research was conducted at the Paiton plant operations and maintenance services division. The condition of transformers was assessed by analyzing dissolved gases using the Rogers ratio method. Results indicate that the transformer at Paiton 9 is in good condition but overheating has occurred and requires treatment. Conversely, the transformers at Paiton 1 and 2 are in poor condition, showing signs of electrical faults and excessive heat. Despite several attempts to add inhibitors and conduct frequent testing, the transformers remained in poor condition, necessitating their replacement or repair.

Keywords

Collaboration network of the authors

40 authors · 128 co-authorship links · 32 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Malikussaleh University
  • Universiti Malaysia Perlis
  • University of Mataram
  • Universitas Tidar
  • Lampung University
  • Medan Area University
  • Udayana University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Rizky AlmunadiansyahMalikussaleh University9
Agung Budi MuljonoUniversity of Mataram5
I Made GinarsaUniversity of Mataram5
Kartika KartikaMalikussaleh University5
Muhammad DaudMalikussaleh University5
Widyana Verawaty SiregarMalikussaleh University5
Fahrian RoidMalikussaleh University4
Armen AbtaMalikussaleh University4
Sultan SultanUniversity of Mataram3
Rahmati RahmatiAffiliation unknown3
Ahmad Zaidi AbdullahUniversiti Malaysia Perlis3
Osea ZebuaLampung University2
Mulyadi Abdul WahidAffiliation unknown2
Mohamad Nur Khairul Hafizi RohaniUniversiti Malaysia Perlis2
N. AzizanUniversiti Malaysia Perlis2
Zara YunizarMalikussaleh University2
Asran AsranMalikussaleh University2
Nura UsrinaMalikussaleh University2
Nuryawan NuryawanMalikussaleh University2
Farhan AkbarMalikussaleh University2
Selamat MelialaMalikussaleh University2
Rosdiana RosdianaMalikussaleh University2
Raihan PutriMalikussaleh University2
Habib SatriaMedan Area University2
Agus DharmaUdayana University1
N. S. B. JamiliUniversiti Malaysia Perlis1
Mohd Rafi AdzmanUniversiti Malaysia Perlis1
Siti Rafidah Abdul RahimUniversiti Malaysia Perlis1
Samila Mat ZaliUniversiti Malaysia Perlis1
Hafizuddin HanafiUniversiti Malaysia Perlis1
Sabar NababanUniversity of Mataram1
Suwito Eko PramonoAffiliation unknown1
Kustiono KustionoAffiliation unknown1
Aida OktarizaAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, first harvested 8 Nov 2026, last seen 16 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Assessing transformer health through analysis of dissolved gases in cooling oil</dc:title>
	<dc:creator>Nisworo, Sapto</dc:creator>
	<dc:creator>Hasibuan, Arnawan</dc:creator>
	<dc:creator>Isa, Muzamir</dc:creator>
	<dc:creator>Nrartha, I Made Ari</dc:creator>
	<dc:creator>Jannah, Misbahul</dc:creator>
	<dc:creator>Muhammad, Muhammad</dc:creator>
	<dc:subject xml:lang="en-US">dissolved gas analysis; insulation system failure; rogers ratio; transformer fault; transformer oil</dc:subject>
	<dc:description xml:lang="en-US">Gases can form within the insulation system for various reasons while a transformer is in operation. If these gases are not promptly and properly managed, they can negatively impact the transformer's performance. Using the dissolved gas analysis (DGA) method to identify and assess the type and quantity of dissolved gases in transformer oil can uncover potential issues within the transformer. This information is crucial for guiding preventive maintenance and necessary repairs. Dissolved gas analysis testing was conducted by extracting transformer oil samples to identify signs of disturbances in the transformer based on the dissolved gas content. This research was conducted at the Paiton plant operations and maintenance services division. The condition of transformers was assessed by analyzing dissolved gases using the Rogers ratio method. Results indicate that the transformer at Paiton 9 is in good condition but overheating has occurred and requires treatment. Conversely, the transformers at Paiton 1 and 2 are in poor condition, showing signs of electrical faults and excessive heat. Despite several attempts to add inhibitors and conduct frequent testing, the transformers remained in poor condition, necessitating their replacement or repair.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21138</dc:identifier>
	<dc:identifier>10.11591/ijape.v13.i4.pp1014-1020</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 13, No 4: December 2024; 1014-1020</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v13.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21138/13262</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Arnawan Hasibuan, Sapto Nisworo, Muzamir Isa</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>