Open access
Journal
SINTA 1
Impact of Thyristor Controlled Series Capacitor Insertion on Short-circuit Calculation in Presence Phase to Earth Fault
International Journal of Applied Power Engineering (IJAPE) · Vol. 1 No. 2 (2012) · pp. 93–104
ISSN 2722-2624, 2252-8792
Published 2012-08-01
Publisher Institute of Advanced Engineering and Science
Language eng
Abstract
This research paper presents a study on phase to earth fault short-circuit calculation with fault resistance on a single transmission line 400 kV in eastern Algerian transmission networks at Algerian Company of Electricity and Gas (Sonelgaz Group) compensated by series Flexible AC Transmission System (FACTS) i.e. Thyristor Controlled Series Capacitor (TCSC) installed in midline. The facts are used for controlling transmission voltage, power flow, reactive power, and damping of power system oscillations at high power transfer levels. The direct impacts of TCSC insertion on the total impedance, active power and reactive power a electrical transmission line and also parameters of short-circuit: symmetrical currents, line currents, symmetrical voltages and line voltages are carried out. More the effects of injected voltage by TCSC for three case studies are presented.
Collaboration network of the authors
10 authors ·
25 co-authorship links
· 5 across different organisations
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
University of Batna 1 Dhofar University Universiti Teknologi MARA University of Brawijaya Affiliation unknown
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, first harvested 8 Nov 2026, last seen 8 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Impact of Thyristor Controlled Series Capacitor Insertion on Short-circuit Calculation in Presence Phase to Earth Fault</dc:title>
<dc:creator>Zellagui, Mohamed</dc:creator>
<dc:creator>Chaghi, Abdelaziz</dc:creator>
<dc:subject xml:lang="en-US">Transmission line; TCSC; Voltage injected; Reactance injected; Earth fault; Symmetrical components</dc:subject>
<dc:description xml:lang="en-US">This research paper presents a study on phase to earth fault short-circuit calculation with fault resistance on a single transmission line 400 kV in eastern Algerian transmission networks at Algerian Company of Electricity and Gas (Sonelgaz Group) compensated by series Flexible AC Transmission System (FACTS) i.e. Thyristor Controlled Series Capacitor (TCSC) installed in midline. The facts are used for controlling transmission voltage, power flow, reactive power, and damping of power system oscillations at high power transfer levels. The direct impacts of TCSC insertion on the total impedance, active power and reactive power a electrical transmission line and also parameters of short-circuit : symmetrical currents, line currents, symmetrical voltages and line voltages are carried out. More the effects of injected voltage by TCSC for three case studies are presented.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2012-08-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/1289</dc:identifier>
<dc:identifier>10.11591/ijape.v1.i2.pp93-104</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 1, No 2: August 2012; 93-104</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v1.i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/1289/733</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Citations and indexing
OpenAlex
Not checked
Crossref
Indexed
via Judul + tahun
0 citations
Counts as reported by each index on 9 Nov 2026; indexes count citations differently.
Cite this article
APA 7
Zellagui, M., & Chaghi, A. (2012). Impact of Thyristor Controlled Series Capacitor Insertion on Short-circuit Calculation in Presence Phase to Earth Fault. International Journal of Applied Power Engineering (IJAPE), 1(2), 93–104. https://doi.org/10.11591/ijape.v1.i2.pp93-104
Copy
IEEE
M. Zellagui and A. Chaghi, “Impact of Thyristor Controlled Series Capacitor Insertion on Short-circuit Calculation in Presence Phase to Earth Fault,” International Journal of Applied Power Engineering (IJAPE), vol. 1, no. 2, pp. 93–104, 2012, doi: 10.11591/ijape.v1.i2.pp93-104.
Copy
Generated from the journal's metadata; check author names before use.