Abstract

This research paper presents a study on phase to earth fault short-circuit calculation with fault resistance on a single transmission line 400 kV in eastern Algerian transmission networks at Algerian Company of Electricity and Gas (Sonelgaz Group) compensated by series Flexible AC Transmission System (FACTS) i.e. Thyristor Controlled Series Capacitor (TCSC) installed in midline. The facts are used for controlling transmission voltage, power flow, reactive power, and damping of power system oscillations at high power transfer levels. The direct impacts of TCSC insertion on the total impedance, active power and reactive power a electrical transmission line and also parameters of short-circuit: symmetrical currents, line currents, symmetrical voltages and line voltages are carried out. More the effects of injected voltage by TCSC for three case studies are presented.

Keywords

Collaboration network of the authors

10 authors · 25 co-authorship links · 5 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Batna 1
  • Dhofar University
  • Universiti Teknologi MARA
  • University of Brawijaya
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Lazhar BougouffaAffiliation unknown3
Heba Ahmed HassanDhofar University2
Hadi SuyonoUniversity of Brawijaya1
Ismail MusirinUniversiti Teknologi MARA1
Muhamad Hazim LokmanAffiliation unknown1
Saiful Izwan SulimanAffiliation unknown1
Rini Nur HasanahAffiliation unknown1
Sharifah Azma Syed MustafaAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, first harvested 8 Nov 2026, last seen 8 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Impact of Thyristor Controlled Series Capacitor Insertion on Short-circuit Calculation in Presence Phase to Earth Fault</dc:title>
	<dc:creator>Zellagui, Mohamed</dc:creator>
	<dc:creator>Chaghi, Abdelaziz</dc:creator>
	<dc:subject xml:lang="en-US">Transmission line; TCSC; Voltage injected; Reactance injected; Earth fault; Symmetrical components</dc:subject>
	<dc:description xml:lang="en-US">This research paper presents a study on phase to earth fault short-circuit calculation with fault resistance on a single transmission line 400 kV in eastern Algerian transmission networks at Algerian Company of Electricity and Gas (Sonelgaz Group) compensated by series Flexible AC Transmission System (FACTS) i.e. Thyristor Controlled Series Capacitor (TCSC) installed in midline. The facts are used for controlling transmission voltage, power flow, reactive power, and damping of power system oscillations at high power transfer levels. The direct impacts of TCSC insertion on the total impedance, active power and reactive power a electrical transmission line and also parameters of short-circuit : symmetrical currents, line currents, symmetrical voltages and line voltages are carried out. More the effects of injected voltage by TCSC for three case studies are presented.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2012-08-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/1289</dc:identifier>
	<dc:identifier>10.11591/ijape.v1.i2.pp93-104</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 1, No 2: August 2012; 93-104</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v1.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/1289/733</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>