Abstract

This research work modelled and optimized the hybrid microgrid energy system for electricity generation at the University of Abuja, Nigeria, using PV, wind, diesel, and battery renewable energy resources. The model and optimization of the system are performed through HOMER software. The estimated university average annual power consumption is 2355 kWh/day, and the optimal load demand is 313.40 kWp. The PV/wind/diesel/ converter/battery hybrid system has the lowest cost of energy (COE) of 0.1616 $/kWh, operating cost of $50,592, and net present cost (NPC) of $1,795,026 but diesel/wind/converter/battery hybrid system has highest COE of 0.4242 $/kWh and NPC of $4,710,983. The optimal total electricity generated is 1,272,778 kWh/yr while electricity generated by PV contribute the highest energy of 1,030,485 kWh/yr (81%), whereas diesel generator and wind produced energy of 93,927 kWh/yr (7.38%) and 148,366 kWh/yr (11.7%) respectively. The wind/diesel/converter/battery hybrid system produced carbon dioxide (CO2) of 557,749 kg/yr. The most environmentally friendly is the wind/PV/battery and PV/battery hybrid system without pollutants emissions, but the diesel/wind/battery hybrid system has the highest rate of pollutants emissions. The result shows that PV’s electrical power is extremely high from February to June, which causes a high rate of irradiance within the specified period.

Keywords

Collaboration network of the authors

34 authors · 143 co-authorship links · 55 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Abuja
  • University of Nigeria
  • Enugu State University of Science and Technology
  • Federal Capital Territory Administration
  • Caritas University
  • University of the Free State
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Thank God Izuchukwu OzueAffiliation unknown5
Muncho Josephine MbunweUniversity of Nigeria5
Emmanuel Majiyebo EronuUniversity of Abuja5
Nnaemeka Genesis AjahUniversity of Nigeria5
Jacob Kehinde OgunjuyigbeUniversity of Abuja4
Olumuyiwa Ajibola AwoniyiUniversity of Abuja4
Sardauna IbrahimFederal Capital Territory Administration2
Oluyinka Olugbenga AinaAffiliation unknown2
Onyekachukwu Denis OzuluAffiliation unknown2
Issac Ojochogwu OnuhAffiliation unknown2
Ikenna Chuddy MbamaluCaritas University2
Isaac Ojochogwu OnuhAffiliation unknown2
Kafayat AdeyemiUniversity of Abuja2
Ngang Bassey NgangUniversity of Abuja2
Stephen Adole BensonUniversity of Abuja2
Solomon Bala OkohUniversity of Abuja2
Iboi EnduranceUniversity of Abuja2
Chijioke EJIMOFORUniversity of Abuja2
Theresa Chinyere OgbuanyaUniversity of the Free State1
Asogwa Tochukwu ChijinduEnugu State University of Science and Technology1
Lois Onyejere NwobodoEnugu State University of Science and Technology1
Onuigbo Chika MarthaEnugu State University of Science and Technology1
Ekene F. OziokoEnugu State University of Science and Technology1
Ozor Godwin OdozoEnugu State University of Science and Technology1
Ebere Uzoka ChidiUniversity of Nigeria1
Emenike Chinedozi EjioguUniversity of Nigeria1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Modeling and optimization of hybrid microgrid energy system: a case study of University of Abuja, Nigeria</dc:title>
	<dc:creator>Araoye, Timothy Oluwaseun</dc:creator>
	<dc:creator>Ashigwuike, Evans Chinemezu</dc:creator>
	<dc:creator>Umar, Sadiq Abubakar</dc:creator>
	<dc:creator>Adebayo, Taiwo Felix</dc:creator>
	<dc:creator>Egoigwe, Sochima Vincent</dc:creator>
	<dc:creator>Odo, Matthew Chinedu</dc:creator>
	<dc:creator>Opata, Chikammadu Emmanuel</dc:creator>
	<dc:creator>Akachukwu, Ohagwu Walte</dc:creator>
	<dc:subject xml:lang="en-US">diesel; HOMER software; hybrid microgrid; modeling; optimization; photovoltaic; wind</dc:subject>
	<dc:description xml:lang="en-US">This research work modelled and optimized the hybrid microgrid energy system for electricity generation at the University of Abuja, Nigeria, using PV, wind, diesel, and battery renewable energy resources. The model and optimization of the system are performed through HOMER software. The estimated university average annual power consumption is 2355 kWh/day, and the optimal load demand is 313.40 kWp. The PV/wind/diesel/ converter/battery hybrid system has the lowest cost of energy (COE) of 0.1616 $/kWh, operating cost of $50,592, and net present cost (NPC) of $1,795,026 but diesel/wind/converter/battery hybrid system has highest COE of 0.4242 $/kWh and NPC of $4,710,983. The optimal total electricity generated is 1,272,778 kWh/yr while electricity generated by PV contribute the highest energy of 1,030,485 kWh/yr (81%), whereas diesel generator and wind produced energy of 93,927 kWh/yr (7.38%) and 148,366 kWh/yr (11.7%) respectively. The wind/diesel/converter/battery hybrid system produced carbon dioxide (CO2) of 557,749 kg/yr. The most environmentally friendly is the wind/PV/battery and PV/battery hybrid system without pollutants emissions, but the diesel/wind/battery hybrid system has the highest rate of pollutants emissions. The result shows that PV’s electrical power is extremely high from February to June, which causes a high rate of irradiance within the specified period.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">Timothy Oluwaseun Araoye</dc:contributor>
	<dc:contributor xml:lang="en-US">Evans Chinemezu Ashigwuike</dc:contributor>
	<dc:contributor xml:lang="en-US">Jonah Chapi</dc:contributor>
	<dc:contributor xml:lang="en-US">Sochima Vincent Egoigwe</dc:contributor>
	<dc:contributor xml:lang="en-US">and Donatus. Onwuha Nwagbara</dc:contributor>
	<dc:date>2023-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22415</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v14.i2.pp1201-1209</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 2: June 2023; 1201-1209</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v14.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22415/14192</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Timothy Oluwaseun Araoye, Evans Chinemezu Ashigwuike, Sadiq Abubakar Umar, Taiwo Felix Adebayo, Sochima Vincent Egoigwe, Matthew Chinedu Odo, Chikammadu Emmanuel Opata, Ohagwu Walte Akachukwu</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>