Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Design and implementation of IoT-based soft starter for induction motor

International Journal of Power Electronics and Drive Systems · Vol. 16 No. 4 (2025) · pp. 2170–2177

DOI
10.11591/ijpeds.v16.i4.pp2170-2177
ISSN
2722-256X, 2088-8694
Published
2025-12-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The practical application of the induction motor is an essential part of electrical engineering. A direct connection of the motors to the mains voltage negatively affects both the motor itself and the mains system as a whole due to high starting current values, as a result, more accidents and shortening the drive system service life. This article discusses the development of designing and implementing of soft starter single-phase IM to reduce the inrush current using the firing angle reduction technique with remote monitoring and control using the ESP32 (node MCU) and Arduino Due microcontrollers. The integration of IoT-based tools software such as VS Code, enables the remote monitoring and control of motor features. Testing shows that the system effectively facilitates remote motor control, providing a flexible and accessible learning environment with minimum starting current, solving the inrush current problem facing IMs. The proposed soft starter gives three cases of firing angle reduction that show a percentage reduction in starting current for these cases (case I, case II, and case III) are 51%, 54% and 64%, respectively. Case III has a maximum starting current is 2.2 A compared to 6.2 A for direct connecting of IM to the power supply (DOL).

Keywords

Collaboration network of the authors

6 authors · 7 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Kufa
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Ameen M. Al-ModafferUniversity of Kufa2
Hur JediUniversity of Kufa1
Hasan Mohammed Jawad Jasim Al-JazaeriUniversity of Kufa1
Zaid AlhadrawiUniversity of Kufa1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Design and implementation of IoT-based soft starter for induction motor</dc:title>
	<dc:creator>Khudhur, Laith Najem Abood</dc:creator>
	<dc:creator>Chlaihawi, Amer Abdulmahdi Jabbar</dc:creator>
	<dc:subject xml:lang="en-US">automation engineering; ESP32 and Arduino Due; IoT-based control; IoT-based microcontrollers; power electronic; remote monitoring and control; soft starter of an induction motor</dc:subject>
	<dc:description xml:lang="en-US">The practical application of the induction motor is an essential part of electrical engineering. A direct connection of the motors to the mains voltage negatively affects both the motor itself and the mains system as a whole due to high starting current values, as a result, more accidents and shortening the drive system service life. This article discusses the development of designing and implementing of soft starter single-phase IM to reduce the inrush current using the firing angle reduction technique with remote monitoring and control using the ESP32 (node MCU) and Arduino Due microcontrollers. The integration of IoT-based tools software such as VS Code, enables the remote monitoring and control of motor features. Testing shows that the system effectively facilitates remote motor control, providing a flexible and accessible learning environment with minimum starting current, solving the inrush current problem facing IMs. The proposed soft starter gives three cases of firing angle reduction that show a percentage reduction in starting current for these cases (case I, case II, and case III) are 51%, 54% and 64%, respectively. Case III has a maximum starting current is 2.2 A compared to 6.2 A for direct connecting of IM to the power supply (DOL).</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24223</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v16.i4.pp2170-2177</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 16, No 4: December 2025; 2170-2177</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v16.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24223/15063</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Laith Najem Abood Khudhur, Amer Abdulmahdi Jabbar Chlaihawi</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>