Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Power Quality Analysis of Vienna Rectifier for BLDC Motor Drive Application

International Journal of Power Electronics and Drive Systems · Vol. 7 No. 1 (2016) · pp. 7–16

DOI
10.11591/ijpeds.v7.i1.pp7-16
ISSN
2722-256X, 2088-8694
Published
2016-03-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This paper presents the power quality improvements for a BLDC driver using Vienna rectifier as front end converter. The major drawbacks in the BLDC motor drive and non linear load applications are the line pollution and depreciation of the power factor. The conventional power factor correction method is not economical and efficient. It requires bulky components as load changes and produce high THD and less Power factor. The front end converter of BLDC bridge inverter drive is proposed by the Vienna rectifier, which can contribute more significantly in improving the power factor and reduce the line pollution. The Vienna rectifier topology is controlled by the constant switching frequency control technique for wide range of load variation and it reduces the THD, improve the power factor and provide a steady DC link voltage to the bridge inverter to drive the BLDC motor. The design calculation and performance characteristics of BLDC motor and Vienna rectifier are verified by using Matlab simulation.

Collaboration network of the authors

10 authors · 15 co-authorship links · 6 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Anna University, Chennai
  • Vellore Institute of Technology University
  • Escola Superior Aberta do Brasil
  • Sathyabama Institute of Science and Technology
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
K. PalanisamyVellore Institute of Technology University2
R. GovarthananVellore Institute of Technology University1
Ramesh PanduranganVellore Institute of Technology University1
S AnandhAnna University, Chennai1
Paramasivam ParamasivamAffiliation unknown1
V. MeenakshiSathyabama Institute of Science and Technology1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Power Quality Analysis of Vienna Rectifier for BLDC Motor Drive Application</dc:title>
	<dc:creator>Srinivasan, K.</dc:creator>
	<dc:creator>Vijayan, S.</dc:creator>
	<dc:creator>Paramasivam, S.</dc:creator>
	<dc:creator>Sundaramoorthi, K.</dc:creator>
	<dc:description xml:lang="en-US">This paper presents the power quality improvements for a BLDC driver using Vienna rectifier as front end converter. The major drawbacks in the BLDC motor drive and non linear load applications are the line pollution and depreciation of the power factor. The conventional power factor correction method is not economical and efficient. It requires bulky components as load changes and produce high THD and less Power factor. The front end converter of BLDC bridge inverter drive is proposed by the Vienna rectifier, which can contribute more significantly in improving the power factor and reduce the line pollution. The Vienna rectifier topology is controlled by the constant switching frequency control technique for wide range of load variation and it reduces the THD, improve the power factor and provide a steady DC link voltage to the bridge inverter to drive the BLDC motor. The design calculation and performance characteristics of BLDC motor and Vienna rectifier are verified by using Matlab simulation.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2016-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/367</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v7.i1.pp7-16</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 7, No 1: March 2016; 7-16</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v7.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/367/192</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2016 K. Srinivasan, S. Vijayan, S. Paramasivam, K. Sundaramoorthi</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>