Abstract

Recently, the renewable energy resources have gained more attention in the electricity sector as promising technology to tackle the depletion in the traditional energy resources. Solar energy grows rapidly due to its vast applications. The performance of Photovoltaic (PV) system is affected by partial shading that results from building, clouds, and fallen leaves. This paper investigates theoretically and experimentally the impacts of various cases of partial shading; such as vertical string, horizontal string, and single cell at environmental conditions on the current-voltage and power-voltage characteristics of 88 W PV panel. In addition, diagonal shading with multi steps is considered in the analysis. The experiments are conducted with considering various parameters; such as shading position and ratio to validate the simulated results. The results show that at 100% shading condition, the maximum power drops by 99.36 %, 43.7%, and 41.15% for horizontal, cellular and vertical shading at the same solar radiation level comparing with their initial state value. Horizontal string shaded has the highest negative impact on the power and efficiency among other types of shadings. The comparison between the theoretical and experimental results reveals considerable agreement between the theoretical and experimental results.

Collaboration network of the authors

8 authors · 11 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Technology - Iraq
  • Alsalam University College
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Dhari Y. MahmoodUniversity of Technology - Iraq3
Marwan Saded AhmedAffiliation unknown1
Marwan E. AhmadAffiliation unknown1
Shaimaa A. HusseinAffiliation unknown1
Ashwaq Qasim HameedAlsalam University College1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Theoretical and experimental analysis of photovoltaic module characteristics under different partial shading conditions</dc:title>
	<dc:creator>Numan, Ali Hussein</dc:creator>
	<dc:creator>Dawood, Zahraa Salman</dc:creator>
	<dc:creator>Hussein, Hashim A.</dc:creator>
	<dc:description xml:lang="en-US">Recently, the renewable energy resources have gained more attention in the electricity sector as promising technology to tackle the depletion in the traditional energy resources. Solar energy grows rapidly due to its vast applications. The performance of Photovoltaic (PV) system is affected by partial shading that results from building, clouds, and fallen leaves. This paper investigates theoretically and experimentally the impacts of various cases of partial shading; such as vertical string, horizontal string, and single cell at environmental conditions on the current-voltage and power-voltage characteristics of 88 W PV panel. In addition, diagonal shading with multi steps is considered in the analysis. The experiments are conducted with considering various parameters; such as shading position and ratio to validate the simulated results. The results show that at 100% shading condition, the maximum power drops by 99.36 %, 43.7%, and 41.15% for horizontal, cellular and vertical shading at the same solar radiation level comparing with their initial state value. Horizontal string shaded has the highest negative impact on the power and efficiency among other types of shadings. The comparison between the theoretical and experimental results reveals considerable agreement between the theoretical and experimental results.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">University of Technology /Electromechanical Engineering Department</dc:contributor>
	<dc:date>2020-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20300</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v11.i3.pp1508-1518</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 3: September 2020; 1508-1518</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v11.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20300/13200</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Ali Hussein Numan, Zahraa Salman Dawood, Hashim A. Hussein</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>