Renewable source penetration into the distribution grid is merely a greater challenge as the powers from renewable sources are not stable and constant. Due to their sporadic operating states the power shared to the grid creates power quality issues. Therefore, an efficient adaptive PMA needs to be adopted for the control of these renewable sources, which controls the power extraction of these sources. For standard power sharing to the variable loads in the grid islanding state, the renewable sources are updated with the ESS module. In this paper, a low-rating distribution test system is considered connected with different renewable sources PV sources, wind farms, and fuel cell plants sharing renewable power. The PV source module is updated with AF-PID replacing the PI controller integrated PMA and ESS module for extensive control of the power of the generation unit during any operating condition. The DC and AC voltages are more stabilized by the upgraded PMA during grid islanding conditions. Mitigation of ripple and harmonic content is achieved by the AF-PID controller varying the proportional, integral, and derivative gains as per the error signal generated. A comparative analysis is carried out on the system validating the effectiveness of the AF-PID controller using MATLAB Simulink software.

Keywords

Collaboration network of the authors

7 authors · 12 co-authorship links · 6 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Visvesvaraya Technological University
  • Annamalai University
  • Bapuji Institute of Engineering and Technology
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Basavarajappa Sokke RameshappaVisvesvaraya Technological University1
Ujwala GajulaAnnamalai University1
Gouthami EragamreddyVisvesvaraya Technological University1
N. Malla ReddyAffiliation unknown1
Remala Geshma KumariAnnamalai University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Adaptive fuzzy PID integrated renewable power management system for off grid and on grid conditions</dc:title>
	<dc:creator>Gopu, Veeranjaneyulu</dc:creator>
	<dc:creator>Nagaraj, Mudakapla Shadaksharappa</dc:creator>
	<dc:subject xml:lang="en-US">AF-PID; energy storage system; MATLAB; photovoltaic; power management algorithm</dc:subject>
	<dc:description xml:lang="en-US">Renewable source penetration into the distribution grid is merely a greater challenge as the powers from renewable sources are not stable and constant. Due to their sporadic operating states the power shared to the grid creates power quality issues. Therefore, an efficient adaptive PMA needs to be adopted for the control of these renewable sources, which controls the power extraction of these sources. For standard power sharing to the variable loads in the grid islanding state, the renewable sources are updated with the ESS module. In this paper, a low-rating distribution test system is considered connected with different renewable sources PV sources, wind farms, and fuel cell plants sharing renewable power. The PV source module is updated with AF-PID replacing the PI controller integrated PMA and ESS module for extensive control of the power of the generation unit during any operating condition. The DC and AC voltages are more stabilized by the upgraded PMA during grid islanding conditions. Mitigation of ripple and harmonic content is achieved by the AF-PID controller varying the proportional, integral, and derivative gains as per the error signal generated. A comparative analysis is carried out on the system validating the effectiveness of the AF-PID controller using MATLAB Simulink software.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23344</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v15.i4.pp2580-2590</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 15, No 4: December 2024; 2580-2590</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v15.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23344/14816</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 VEERANJANEYULU GOPU, Dr.M.S. NAGARAJ</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>