Experimentally evaluating electrical outputs of a PV-T system in Jordan

International Journal of Power Electronics and Drive Systems · Vol. 12 No. 1 (2021) · pp. 421–430

DOI
10.11591/ijpeds.v12.i1.pp421-430
ISSN
2722-256X, 2088-8694
Published
2021-03-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This experimental work is looking at the properties of photovoltaic/thermal (PV-T) system, which had designed to increase the output power of the PV panel for the climate of Zarqa, Jordan. Operating temperature of the PV module has a significant impact on the performance of the PV module. However, most of the radiation energy absorbed by the PV panel is converted into heat, which is normally lost and provides no value. In order to decrease the operating temperature of the PV panel, a water cooling system with a control system had designed. Experimentally, when the PV module was operating under active water-cooling condition using the backside cooling technique, the temperature dropped significantly, which led to an increase in the electrical efficiency of solar cells by 6.86%.

Keywords

Collaboration network of the authors

10 authors · 18 co-authorship links · 8 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Hashemite University
  • Jordan University of Science and Technology
  • King Abdulaziz University
  • Al Hussein Technical University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nithiyananthan KannanKing Abdulaziz University1
Fadi Nessir ZghoulJordan University of Science and Technology1
Yousra Hussein Al-BakrawiJordan University of Science and Technology1
Ahmad Bani YaseenHashemite University1
Moh’d Sami AshhabAl Hussein Technical University1
Mohammad JuaidyHashemite University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 29 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Experimentally evaluating electrical outputs of a PV-T system in Jordan</dc:title>
	<dc:creator>Etier, Issa</dc:creator>
	<dc:creator>Nijmeh, Salem</dc:creator>
	<dc:creator>Shdiefat, Mohammed</dc:creator>
	<dc:creator>Al-Obaidy, Omar</dc:creator>
	<dc:subject xml:lang="en-US">Photovoltaic/thermal system, Control system, Water active-cooling, Solar panel, Efficiency of panel</dc:subject>
	<dc:description xml:lang="en-US">This experimental work is looking at the properties of photovoltaic/thermal (PV-T) system, which had designed to increase the output power of the PV panel for the climate of Zarqa, Jordan. Operating temperature of the PV module has a significant impact on the performance of the PV module. However, most of the radiation energy absorbed by the PV panel is converted into heat, which is normally lost and provides no value. In order to decrease the operating temperature of the PV panel, a water cooling system with a control system had designed. Experimentally, when the PV module was operating under active water-cooling condition using the backside cooling technique, the temperature dropped significantly, which led to an increase in the electrical efficiency of solar cells by 6.86%.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2021-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20397</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v12.i1.pp421-430</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 1: March 2021; 421-430</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v12.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20397/13363</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Issa Etier, Salem Nijmeh, Mohammed Shdiefat, Omar Al-Obaidy</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>