Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Enhanced decoupled current control with voltage compensation for modular multilevel converter (MMC) based STATCOM

International Journal of Power Electronics and Drive Systems · Vol. 10 No. 3 (2019) · pp. 1483–1499

DOI
10.11591/ijpeds.v10.i3.pp1483-1499
ISSN
2722-256X, 2088-8694
Published
2019-09-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This paper presents the application of modular multilevel converter (MMC) as a static compensator (STATCOM) for reactive current control. The current control is mostly achieved using proportional controller, proportional-integral (PI) controller, and hysteresis controller among others. PI controllers have the advantage of low harmonics and small variations. However, due to the PI controller’s dependency on the system parameters and also due to the variations within the MMC during capacitors voltage control, variation in the MMC performance during the STATCOM non-ideal operations occur. To mitigate this, an improved performance of MMC will be presented using vector-based compensation concept. The proposed control will be introduced to depress the effect of the dynamics of the MMC based STATCOM non-ideal variations considering the impact of the voltage disturbance. This will be achieved by the introduction of voltage variables to subtract the transient variations from PI controllers’ outputs at the grid-interface; thus, improving the performance.

Collaboration network of the authors

8 authors · 18 co-authorship links · 3 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Ahmadu Bello University
  • University of Nottingham
  • Bayero University Kano
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Y. Jibril MAhmadu Bello University1
Abubakar AbdulkarimAhmadu Bello University1
Sulaiman BabaniBayero University Kano1
Gaddafi Sani ShehuAhmadu Bello University1
Ibrahim Sani MaduguAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Enhanced decoupled current control with voltage compensation for modular multilevel converter (MMC) based STATCOM</dc:title>
	<dc:creator>Lawan, Abdurrahman Umar</dc:creator>
	<dc:creator>Almurib, Haider A.F.</dc:creator>
	<dc:creator>Khor, Jeen G.</dc:creator>
	<dc:description xml:lang="en-US">This paper presents the application of modular multilevel converter (MMC) as a static compensator (STATCOM) for reactive current control. The current control is mostly achieved using proportional controller, proportional-integral (PI) controller, and hysteresis controller among others. PI controllers have the advantage of low harmonics and small variations.  However, due to the PI controller’s dependency on the system parameters and also due to the variations within the MMC during capacitors voltage control, variation in the MMC performance during the STATCOM non-ideal operations occur. To mitigate this, an improved performance of MMC will be presented using vector-based compensation concept. The proposed control will be introduced to depress the effect of the dynamics of the MMC based STATCOM non-ideal variations considering the impact of the voltage disturbance. This will be achieved by the introduction of voltage variables to subtract the transient variations from PI controllers’ outputs at the grid-interface; thus, improving the performance.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2019-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/11552</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v10.i3.pp1483-1499</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 10, No 3: September 2019; 1483-1499</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v10.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/11552/12874</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2019 Abdurrahman Umar Lawan, Haider A.F. Almurib, Jeen G. Khor</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>