Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Sliding Mode Observers-based Fault Detection and Isolation for Wind Turbine-driven Induction Generator

International Journal of Power Electronics and Drive Systems · Vol. 8 No. 3 (2017) · pp. 1345–1358

DOI
10.11591/ijpeds.v8.i3.pp1345-1358
ISSN
2722-256X, 2088-8694
Published
2017-09-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Inter-turn short-circuit (ITSC) faults on the induction machine has received much attention in the recent years. Early detection of such faults in wind turbine systems would allow to avoid fluctuation on wind power output and maintain the reliability level. In this paper, Sliding Mode Observers (SMO)-based fault detection and isolation method is developed for induction generator (IG)-based variable-speed grid-connected wind turbines. Firstly, the dynamic model of the wind turbine and IG was given and then, the control was made based on Maximum Power Point Tracking (MPPT) method. The IG closed-loop via Indirect Rotor Flux Oriented Control (IRFOC) scheme was also described. Hence, the performance of the wind turbine system and the stability of injected power to the grid were analyzed under the ITSC fault conditions. The control schemes were proved to be inherently unstable under the faulty conditions. Then, robust SMO were investigated to design an ITSC fault detection and isolation scheme. Finally, simulation results of ITSC detection and isolation in the variable-speed grid-connected wind turbine with affected IG confirm the theoretical development.

Collaboration network of the authors

13 authors · 32 co-authorship links · 12 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Monastir
  • Ecole Nationale d'Ingénieurs de Monastir
  • Université de Cergy-Pontoise
  • Qatar University
  • Ferghana Polytechnical Institute
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Hamdi EcheikhEcole Nationale d'Ingénieurs de Monastir3
Atif IqbalQatar University2
Hichem KesraouiEcole Nationale d'Ingénieurs de Monastir2
Ramzi TrabelsiAffiliation unknown2
Atif IqbalFerghana Polytechnical Institute2
Anissa HosseyniAffiliation unknown1
Sanjeeve KumarAffiliation unknown1
R AlammariAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 16 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Sliding Mode Observers-based Fault Detection and Isolation for Wind Turbine-driven Induction Generator</dc:title>
	<dc:creator>Sellami, T.</dc:creator>
	<dc:creator>Berriri, H.</dc:creator>
	<dc:creator>Jelassi, S.</dc:creator>
	<dc:creator>Darcherif, A. M.</dc:creator>
	<dc:creator>Mimouni, M. F.</dc:creator>
	<dc:description xml:lang="en-US">Inter-turn short-circuit (ITSC) faults on the induction machine has received much attention in the recent years. Early detection of such faults in wind turbine systems would allow to avoid fluctuation on wind power output and maintain the reliability level. In this paper, Sliding Mode Observers (SMO)-based fault detection and isolation method is developed for induction generator (IG)-based variable-speed grid-connected wind turbines. Firstly, the dynamic model of the wind turbine and IG was given and then, the control was made based on Maximum Power Point Tracking (MPPT) method. The IG closed-loop via Indirect Rotor Flux Oriented Control (IRFOC) scheme was also described. Hence, the performance of the wind turbine system and the stability of injected power to the grid were analyzed under the ITSC fault conditions. The control schemes were proved to be inherently unstable under the faulty conditions. Then, robust SMO were investigated to design an ITSC fault detection and isolation scheme. Finally, simulation results of ITSC detection and isolation in the variable-speed grid-connected wind turbine with affected IG confirm the theoretical development.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2017-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/7978</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v8.i3.pp1345-1358</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 8, No 3: September 2017; 1345-1358</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v8.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/7978/7033</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 T. Sellami, H. Berriri, S. Jelassi, A. M. Darcherif, M. F. Mimouni</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>