Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Asymmetrical four-wire cascaded h-bridge multi-level inverter based shunt active power filter supplied by a photovoltaic source

International Journal of Power Electronics and Drive Systems · Vol. 12 No. 3 (2021) · pp. 1673–1686

DOI
10.11591/ijpeds.v12.i3.pp1673-1686
ISSN
2722-256X, 2088-8694
Published
2021-09-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This paper presents a novel shunt active power filter (SAPF). The power converter that is used in this SAPF is constructed from a four-leg asymmetric multi-level cascaded H-bridge (CHB) inverter that is fed from a photovoltaic source. A three-dimensional space vector modulation (3D-SVPWM) technique is adopted in this work. The multi-level inverter can generate 27-level output with harmonic content is almost zero. In addition to the capability to inject reactive power and mitigating the harmonics, the proposed SAPF has also, the ability to inject real power as it is fed from a PV source. Moreover, it has a fault-tolerant capability that makes the SAPF maintaining its operation under a loss of one leg of the multi-level inverter due to an open-circuit fault without any degradation in the performance. The proposed SAPF is designed and simulated in MATLAB SIMULINK using a single nonlinear load and the results have shown a significant reduction in total harmonics distortion (THD) of the source current under the normal operating condition and post a failure in one phase of the SAPF. Also, similar results are obtained when IEEE 15 bus network is used.

Keywords

Collaboration network of the authors

4 authors · 3 co-authorship links · 1 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • An-Najah National University
  • University of Nottingham
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Mark SumnerUniversity of Nottingham4
Ameen MadiAn-Najah National University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Asymmetrical four-wire cascaded h-bridge multi-level inverter based shunt active power filter supplied by a photovoltaic source</dc:title>
	<dc:creator>Saleh, Kamel</dc:creator>
	<dc:creator>Mahmoud, Omar</dc:creator>
	<dc:subject xml:lang="en-US">Fault-tolerant; Multi-level inverter; PV system; SAPF</dc:subject>
	<dc:description xml:lang="en-US">This paper presents a novel shunt active power filter (SAPF). The power converter that is used in this SAPF is constructed from a four-leg asymmetric multi-level cascaded H-bridge (CHB) inverter that is fed from a photovoltaic source. A three-dimensional space vector modulation (3D-SVPWM) technique is adopted in this work. The multi-level inverter can generate 27-level output with harmonic content is almost zero. In addition to the capability to inject reactive power and mitigating the harmonics, the proposed SAPF has also, the ability to inject real power as it is fed from a PV source. Moreover, it has a fault-tolerant capability that makes the SAPF maintaining its operation under a loss of one leg of the multi-level inverter due to an open-circuit fault without any degradation in the performance. The proposed SAPF is designed and simulated in MATLAB SIMULINK using a single nonlinear load and the results have shown a significant reduction in total harmonics distortion (THD) of the source current under the normal operating condition and post a failure in one phase of the SAPF. Also, similar results are obtained when IEEE 15 bus network is used.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2021-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21457</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v12.i3.pp1673-1686</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 3: September 2021; 1673-1686</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v12.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21457/13508</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Kamel Saleh, Omar Mahmoud</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>