Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Investigation of distributed generation units placement and sizing based on voltage stability condition indicator (VSCI)

International Journal of Power Electronics and Drive Systems · Vol. 10 No. 3 (2019) · pp. 1317–1323

DOI
10.11591/ijpeds.v10.i3.pp1317-1323
ISSN
2722-256X, 2088-8694
Published
2019-09-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Voltage instability in power distribution systems can result in voltage collapse throughout the grid. Today, with the advanced of power generation technology from renewable sources, concerns of utility companies are much being focused on the stability of the grid when there is an integration of distributed generation (DG) in the system. This paper presents a study on DG units placement and sizing in a radial distribution network by using a pre-developed index called Voltage Stability Condition Index (VSCI). In this paper, VSCI is used to determine DG placement candidates, while the value of power losses is used to identify the best DG placement. The proposed method is tested on a standard 33-bus radial distribution network and compared with existing Ettehadi and Aman methods. The effectiveness of the method is presented in terms of reduction in power system losses, maximization of system loadability and voltage quality improvement. Results show that VSCI can be utilized as the voltage stability indicator for DG placement in radial distribution power system. The integration of DG is found to improve voltage stability by increasing the system loadability and reducing the power losses of the network.

Collaboration network of the authors

14 authors · 41 co-authorship links · 12 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknologi MARA
  • Universiti Tenaga Nasional
  • Universiti Teknikal Malaysia Melaka
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Hasmaini MohamadUniversiti Teknologi MARA10
Siti Zaliha Mohammad NoorUniversiti Teknologi MARA3
Yusnita Mohd AliUniversiti Teknologi MARA3
Nur Diyana Shahirah Mohd ZainUniversiti Teknologi MARA3
Mohammad Shariful IslamUniversiti Teknologi MARA2
Mohd Danish Irfan Mohd SufianUniversiti Teknologi MARA2
Nofri Yenita DahlanUniversiti Teknologi MARA1
Elia Erwani HassanUniversiti Teknikal Malaysia Melaka1
Nur Syifa Nasyrah RazaliUniversiti Teknologi MARA1
Nurfadzilah AhmadUniversiti Teknologi MARA1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 16 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Investigation of distributed generation units placement and sizing based on voltage stability condition indicator (VSCI)</dc:title>
	<dc:creator>Raj, Arvind</dc:creator>
	<dc:creator>Aziz, Nur Fadilah Ab</dc:creator>
	<dc:creator>Yasin, Zuhaila Mat</dc:creator>
	<dc:creator>Salim, Nur Ashida</dc:creator>
	<dc:description xml:lang="en-US">Voltage instability in power distribution systems can result in voltage collapse throughout the grid. Today, with the advanced of power generation technology from renewable sources, concerns of utility companies are much being focused on the stability of the grid when there is an integration of distributed generation (DG) in the system.  This paper presents a study on DG units placement and sizing in a radial distribution network by using a pre-developed index called Voltage Stability Condition Index (VSCI). In this paper, VSCI is used to determine DG placement candidates, while the value of power losses is used to identify the best DG placement. The proposed method is tested on a standard 33-bus radial distribution network and compared with existing Ettehadi and Aman methods. The effectiveness of the method is presented in terms of reduction in power system losses, maximization of system loadability and voltage quality improvement. Results show that VSCI can be utilized as the voltage stability indicator for DG placement in radial distribution power system. The integration of DG is found to improve voltage stability by increasing the system loadability and reducing the power losses of the network.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2019-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/19856</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v10.i3.pp1317-1323</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 10, No 3: September 2019; 1317-1323</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v10.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/19856/12854</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2019 Arvind Raj, Nur Fadilah Ab Aziz, Zuhaila Mat Yasin, Nur Ashida Salim</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>