Development of smart online partial discharge monitoring system for medium voltage power cable

International Journal of Power Electronics and Drive Systems · Vol. 10 No. 4 (2019) · pp. 2190–2197

DOI
10.11591/ijpeds.v10.i4.pp2190-2197
ISSN
2722-256X, 2088-8694
Published
2019-12-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This paper presents, the development of smart online partial discharge (PD) monitoring system for medium voltage (MV) underground power cable. PD monitoring is the highly efficient tool to monitor insulation degradation for high voltage (HV) equipment in order to avoid failures or breakdown. Selection of improved technology and performance of PD detection sensor, effective measurement technique and smart user friendly of graphical user interface (GUI) system are contributed towards the development of efficient monitoring system. This paper addresses three main aspects which are needed in completing the monitoring system. They are, the use of Rogowski coil (RC) as detection sensor, processing unit using Alterra board and integrated with GUI PD monitoring system for underground cable using LabVIEW. The monitoring system is compared to the conventional method with the PD signal used is measured from the real on-site measurement in order to analyse its performance. The analysis is performed in MATLAB and LabVIEW software’s environment and the maximum peak of PD signal is enabled to view using GUI which complete with the location information of PD source. Furthermore, this paper has contributed to solve the problem in selection the simplified and practical approach for PD sensor and monitoring system. In the perspective of automated condition monitoring, this smart online PD monitoring system provides a complete solution towards latest industrial revolutions

Collaboration network of the authors

39 authors · 127 co-authorship links · 62 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Malaysia Perlis
  • Malikussaleh University
  • Medan Area University
  • University of Technology Malaysia
  • Universitas Sumatera Utara
  • Universiti Teknikal Malaysia Melaka
  • University of Mataram
  • Other organisations
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Haziah Abdul HamidUniversiti Malaysia Perlis4
Mohd Harith AmlusUniversiti Malaysia Perlis4
I Made Ari NrarthaUniversity of Mataram2
Arnawan HasibuanMalikussaleh University2
Mohamad Fani SulaimaUniversiti Teknikal Malaysia Melaka2
Zul Hasrizal BohariUniversiti Teknikal Malaysia Melaka2
Ping Jack SohUniversiti Malaysia Perlis2
N. S. B. JamiliUniversiti Malaysia Perlis1
Mohd Rafi AdzmanUniversiti Malaysia Perlis1
Siti Rafidah Abdul RahimUniversiti Malaysia Perlis1
Samila Mat ZaliUniversiti Malaysia Perlis1
Hafizuddin HanafiUniversiti Malaysia Perlis1
Misbahul JannahMalikussaleh University1
Muhammad MuhammadMalikussaleh University1
Sapto NisworoUniversitas Tidar1
Habib SatriaMedan Area University1
Syafii SyafiiAndalas University1
Moranain MungkinMedan Area University1
Dina MaizanaMedan Area University1
Muhammad Yonggi PurizaUniversity of Bangka Belitung1
Shameem AhmadAmerican International University-Bangladesh1
Surya HardiUniversitas Sumatera Utara1
Raja HarahapUniversitas Sumatera Utara1
Nurdin NurdinState University of Gorontalo1
Widyana Verawaty SiregarMalikussaleh University1
Muhammad Aulia DeskyMalikussaleh University1
Herman FithraMalikussaleh University1
Robi KurniawanMalikussaleh University1
Chin‐Leong WooiUniversity of Technology Malaysia1
Ali I ElgayarUniversity of Technology Malaysia1
S. N. M. ArshadUniversiti Malaysia Perlis1
Ahmad Muhyiddin YusofUniversiti Malaysia Perlis1
Zulkurnain Abul-MalekUniversity of Technology Malaysia1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 16 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Development of smart online partial discharge monitoring system for medium voltage power cable</dc:title>
	<dc:creator>Abdullah, A. Z.</dc:creator>
	<dc:creator>Isa, M.</dc:creator>
	<dc:creator>Rohani, M. N. K. H.</dc:creator>
	<dc:creator>Jamalil, S. A. S.</dc:creator>
	<dc:creator>Abdullah, A. N. N.</dc:creator>
	<dc:creator>Azizan, N.</dc:creator>
	<dc:description xml:lang="en-US">This paper presents, the development of smart online partial discharge (PD) monitoring system for medium voltage (MV) underground power cable. PD monitoring is the highly efficient tool to monitor insulation degradation for high voltage (HV) equipment in order to avoid failures or breakdown. Selection of improved technology and performance of PD detection sensor, effective measurement technique and smart user friendly of graphical user interface (GUI) system are contributed towards the development of efficient monitoring system. This paper addresses three main aspects which are needed in completing the monitoring system. They are, the use of Rogowski coil (RC) as detection sensor, processing unit using Alterra board and integrated with GUI PD monitoring system for underground cable using LabVIEW. The monitoring system is compared to the conventional method with the PD signal used is measured from the real on-site measurement in order to analyse its performance. The analysis is performed in MATLAB and LabVIEW software’s environment and the maximum peak of PD signal is enabled to view using GUI which complete with the location information of PD source. Furthermore, this paper has contributed to solve the problem in selection the simplified and practical approach for PD sensor and monitoring system. In the perspective of automated condition monitoring, this smart online PD monitoring system provides a complete solution towards latest industrial revolutions</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2019-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20371</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v10.i4.pp2190-2197</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 10, No 4: December 2019; 2190-2197</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v10.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20371/12953</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2019 A. Z. Abdullah, M. Isa, M. N. K. H. Rohani, S. A. S. Jamalil, A. N. N. Abdullah, N. Azizan</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>