Abstract

This paper proposes a reduced switch Open-Delta (OD-VSC) voltage controller for an standalone asynchronous generator (SAG), also known as the self-excited induction generator (SEIG),used in constant power applications such as pico hydro uncontrolled turbine driven isolated induction generator (IAG) for feeding three-phase loads. The proposed reduced switch voltage controller is used to regulate and control the generator terminal voltage as it is subjected to voltage drops, dips or flickers when the isolated power system is subjected to various critical loads. Generally this purpose is carried out by a STATCOM comprising of a three-leg six-switch inverter structure. Here, in this work the DSTATCOM is realized using a three-leg four-switch insulated gate bipolar transistor (IGBT)-based current controlled voltage-sourced converter (CC-VSC) and a self-supporting dc bus containing two split capacitors. The proposed generating system along with the controller is modeled and simulated in MATLAB along with Simulink and power system blockset (PSB) toolboxes. The system is simulated and the capability of the isolated generating system along with the reduced switch based voltage controller is presented here where the generator feeds linear and non-linear loads are investigated.

Collaboration network of the authors

9 authors · 15 co-authorship links · 11 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Jadavpur University
  • RCC Institute of Information Technology
  • Meghnad Saha Institute of Technology
  • Guru Nanak Institute of Technology
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nijam Uddin MollaRCC Institute of Information Technology1
Debashis ChatterjeeJadavpur University1
Arabinda DasJadavpur University1
Epsita DasMeghnad Saha Institute of Technology1
Ambarnath BanerjiAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Open-Delta VSC Based Voltage Controller in Isolated Power Systems</dc:title>
	<dc:creator>Bhattacharya, Shilpi</dc:creator>
	<dc:creator>Deb, Prabal</dc:creator>
	<dc:creator>Biswas, Sujit K</dc:creator>
	<dc:creator>Banerjee, Ambarnath</dc:creator>
	<dc:description xml:lang="en-US">This paper proposes a reduced switch Open-Delta (OD-VSC) voltage controller for an standalone asynchronous generator (SAG), also known as the self-excited induction generator (SEIG),used in constant power applications such as pico hydro uncontrolled turbine driven isolated induction generator (IAG) for feeding three-phase loads. The proposed reduced switch voltage controller is used to regulate and control the generator terminal voltage as it is subjected to voltage drops, dips or flickers when the isolated power system is subjected to various critical loads. Generally this purpose is carried out by a STATCOM comprising of a three-leg six-switch inverter structure. Here, in this work the DSTATCOM is realized using a three-leg four-switch insulated gate bipolar transistor (IGBT)-based current controlled voltage-sourced converter (CC-VSC) and a self-supporting dc bus containing two split capacitors. The proposed generating system along with the controller is modeled and simulated in MATLAB along with Simulink and power system blockset (PSB) toolboxes. The system is simulated and the capability of the isolated generating system along with the reduced switch based voltage controller is presented here where the generator feeds linear and non-linear loads are investigated.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:date>2015-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/5136</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v6.i2.pp376-386</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 6, No 2: June 2015; 376-386</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v6.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/5136/4485</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2015 Shilpi Bhattacharya, Prabal Deb, Sujit K Biswas, Ambarnath Banerjee</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>