Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Motor Command and Supervision Using the Magnetic Components of the Insulation Fault Protection System for Power Line Communication

International Journal of Power Electronics and Drive Systems · Vol. 8 No. 1 (2017) · pp. 204–212

DOI
10.11591/ijpeds.v8.i1.pp204-212
ISSN
2722-256X, 2088-8694
Published
2017-03-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This work proposes an additional function for a VSD (Variable Speed Drive) which sends and receives information over the power lines and simultaneously, implements the protection against insulation faults to earth. Using the magnetic components of the insulation fault protection system of the motor, the prototype injects and detects the communication signals over the power line. The system works on both communication schemes, with and without the PWM (Pulse Width Modulation) perturbation in the power lines, which are the two possible real applications. In order to set a proper communication between the motor and the drive, the communication channel was modeled and the noise was characterized. An FSK modulation and demodulation scheme was developed and tested. A 10 kbps communication over a 125 m length of cable and over a 1 km pi-section model of the same cable was successfully achieved with the laboratory prototype.

Collaboration network of the authors

10 authors · 16 co-authorship links · 5 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universidad de Buenos Aires
  • Balseiro Institute
  • Comisión Nacional de Energía Atómica
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
M. J. CarraUniversidad de Buenos Aires1
José LipovetzkyBalseiro Institute1
Tomas A. GonzalezAffiliation unknown1
Daniel O. MercuriAffiliation unknown1
Maximo E. PupareliAffiliation unknown1
Diego A. FanegoUniversidad de Buenos Aires1
Orlando Silvio SandiniUniversidad de Buenos Aires1
Andres Juan KreinerComisión Nacional de Energía Atómica1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 29 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Motor Command and Supervision Using the Magnetic Components of the Insulation Fault Protection System  for Power Line Communication</dc:title>
	<dc:creator>Bulacio, Matias Fernando</dc:creator>
	<dc:creator>Tacca, Hernan Emilio</dc:creator>
	<dc:description xml:lang="en-US">This work proposes an additional function for a VSD (Variable Speed Drive) which sends and receives information over the power lines and simultaneously, implements the protection against insulation faults to earth. Using the magnetic components of the insulation fault protection system of the motor, the prototype injects and detects the communication signals over the power line. The system works on both communication schemes, with and without the PWM (Pulse Width Modulation) perturbation in the power lines, which are the two possible real applications. In order to set a proper communication between the motor and the drive, the communication channel was modeled and the noise was characterized. An FSK modulation and demodulation scheme was developed and tested. A 10 kbps communication over a 125 m length of cable and over a 1 km pi-section model of the same cable was successfully achieved with the laboratory prototype.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2017-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6147</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v8.i1.pp204-212</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 8, No 1: March 2017; 204-212</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v8.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6147/5996</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 Matias Fernando Bulacio, Hernan Emilio Tacca</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>