Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Optimal FOPID control for improved load frequency regulation of a renewable-integrated hybrid power system using the Puma optimizer

International Journal of Power Electronics and Drive Systems · Vol. 17 No. 3 (2026) · pp. 2013–2028

DOI
10.11591/ijpeds.v17.i3.pp2013-2028
ISSN
2722-256X, 2088-8694
Published
2026-09-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This study addresses the challenge of frequency stabilization in a complex two-area hybrid power system subjected to load disturbances. Area 1 comprises thermal, hydro, and wind power generation, while Area 2 integrates thermal, hydro, and gas turbine units, presenting a diverse and realistic system for control strategies. The inherent nonlinearities and varying dynamics of these generation sources, particularly wind power, necessitate a robust and advanced control solution. The proposed Puma optimizer-driven fractional-order proportional-integral-derivative (FOPID) controller is developed to enhance dynamic performance under load disturbances and renewable energy fluctuations. The proposed Puma optimizer-based fractional-order proportional-integral-derivative (PO-FOPID) controller is rigorously validated against a Puma optimizer-based proportional-integral-derivative (PO-PID) controller, a PSO-tuned PID controller, and a PSO-tuned fractional-order PID (PSO-FOPID) controller. The settling time and peak overshoot/undershoot are considered for comparison, while the integral of time multiplied by the absolute error (ITAE) performance index is used as the objective function to be minimized. The findings highlight the potential of combining Puma optimizer with fractional-order control for reliable frequency regulation in modern hybrid power systems.

Keywords

Collaboration network of the authors

26 authors · 61 co-authorship links · 14 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • KIIT University
  • Netaji Subhas University of Technology
  • SR University
  • Centurion University of Technology and Management
  • Vignan's Foundation for Science, Technology & Research
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Ranjan Keshari PatiAffiliation unknown2
Shobha AgarwalKIIT University1
Aishwarya SahooKIIT University1
Sanitha MishraKIIT University1
Sunita PahadasinghKIIT University1
Chitralekha JenaKIIT University1
Mitali RayKIIT University1
Padarbinda SamalKIIT University1
Sthitprajna MishraKIIT University1
Subhra DebdasKIIT University1
Atri BandyopadhyayKIIT University1
Srikanth VelpulaSR University1
Amit Kumar SahooCenturion University of Technology and Management1
Pabitra Kumar TripathyAffiliation unknown1
Sreedhar MadichettyKIIT University1
Abhijit DasguptaKIIT University1
J. PatiKIIT University1
Snehalika SnehalikaKIIT University1
Ranjeeta PatelKIIT University1
Amruta AbhishekKIIT University1
Jayanta Kumar SahuVignan's Foundation for Science, Technology & Research1
Satyaranjan JenaKIIT University1
Maneesh YadavKIIT University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 16 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Optimal FOPID control for improved load frequency regulation of a renewable-integrated hybrid power system using the Puma optimizer</dc:title>
	<dc:creator>Samal, Mitali</dc:creator>
	<dc:creator>Panigrahi, Chinmoy Kumar</dc:creator>
	<dc:creator>Gupta, Deepak Kumar</dc:creator>
	<dc:subject xml:lang="en-US">fractional-order proportional-integral-derivative; hybrid power system; load frequency control; particle swarm optimization; puma optimizer</dc:subject>
	<dc:description xml:lang="en-US">This study addresses the challenge of frequency stabilization in a complex two-area hybrid power system subjected to load disturbances. Area 1 comprises thermal, hydro, and wind power generation, while Area 2 integrates thermal, hydro, and gas turbine units, presenting a diverse and realistic system for control strategies. The inherent nonlinearities and varying dynamics of these generation sources, particularly wind power, necessitate a robust and advanced control solution. The proposed Puma optimizer-driven fractional-order proportional-integral-derivative (FOPID) controller is developed to enhance dynamic performance under load disturbances and renewable energy fluctuations. The proposed Puma optimizer-based fractional-order proportional-integral-derivative (PO-FOPID) controller is rigorously validated against a Puma optimizer-based proportional-integral-derivative (PO-PID) controller, a PSO-tuned PID controller, and a PSO-tuned fractional-order PID (PSO-FOPID) controller. The settling time and peak overshoot/undershoot are considered for comparison, while the integral of time multiplied by the absolute error (ITAE) performance index is used as the objective function to be minimized. The findings highlight the potential of combining Puma optimizer with fractional-order control for reliable frequency regulation in modern hybrid power systems.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24770</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v17.i3.pp2013-2028</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 17, No 3: September 2026; 2013-2028</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v17.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24770/15331</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Mitali Samal, Chinmoy Kumar Panigrahi, Deepak Kumar Gupta</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>