Differences in the impact of harmonic distortion due to the installation of electronic load controller in self-excited induction generator and synchronous generator

International Journal of Power Electronics and Drive Systems · Vol. 10 No. 1 (2019) · pp. 104–116

DOI
10.11591/ijpeds.v10.i1.pp104-116
ISSN
2722-256X, 2088-8694
Published
2019-03-01
Publisher
Institute of Advanced Engineering and Science
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

In general, the application of Self-Excited Induction Generator (SEIG) or Synchronous Generator (SG) on the Stand-Alone Micro Hydel Power Plant (MHPP) is equipped with Electronic Load Controller (ELC) to control generator output during variations in consumer load. One type of ELC that is cheap and rigid developed today is the ELC, which is constructed by the uncontrolled bridge rectifier with DC Chopper. Based on the operational concept, basically this type of ELC can be implemented on both SEIG and SG, but both of these generators will have a different harmonic distortion effect on the output and its load. This paper examines the differences in the effects of harmonic distortions due to ELC installation on SEIG and SG. The initial stage of this study was to design the ELC developed. Then, the harmonic distortion response due to the installation of ELC on SEIG and SG is tested, which includes harmonic distortion in: stator current, PCC voltage, and consumer load current. THDI (Current Total Harmonic Distortion) stator current at SEIG with ELC has shown an average value smaller than the THD stator current in SG with ELC. Likewise, the THDV (Voltage Total Harmonic Distortion) value of PCC voltage and THDI value of the current consumer load on SEIG equipped with ELC has been shown to be smaller than the THDV value of PCC voltage and THDI value of the current consumer load on SG equipped with ELC. The effects of harmonic distortions due to the installation of ELCs that developed in this study on SEIG is still within the permitted limits, while on the SG, the harmonic distortion reduction is needed at the generator output.

Collaboration network of the authors

40 authors · 86 co-authorship links · 13 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Medan Area University
  • Andalas University
  • Universiti Malaysia Perlis
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Habib SatriaMedan Area University8
Indri DayanaMedan Area University4
Muhammad Imran HamidAndalas University4
Moranain MungkinMedan Area University3
Dadan RamdanMedan Area University3
Dina MaizanaMedan Area University3
Muhammad Fadlan SiregarMedan Area University3
Nukhe Andri SilvianaMedan Area University2
Muhammad IrwantoUniversiti Malaysia Perlis2
Novizon NovizonAffiliation unknown2
Rahmad B. Y. SyahAffiliation unknown2
Krismadinata KrismadinataAffiliation unknown2
Rahmad SyahMedan Area University1
Abdul RajabAndalas University1
Hanalde AndreAndalas University1
Baharuddin BaharuddinAndalas University1
Harry GumilangAffiliation unknown1
Sulistyo Agung Dwi KurniawanAffiliation unknown1
Kamsidjo Budi UtomoAffiliation unknown1
Imam Fauzi Ath ThaariqAffiliation unknown1
Lusi Ngestina PutriAffiliation unknown1
Anggi Verresya DwiAffiliation unknown1
Apri YuliyanaAffiliation unknown1
Triyanto TriyantoAffiliation unknown1
Dewi Barata Siswa LelanaAffiliation unknown1
Novita Tri LestariAffiliation unknown1
Onang MurtiyosoAffiliation unknown1
Restu Angening PawekasAffiliation unknown1
Eko SugiartoAffiliation unknown1
Qoimatun NajahAffiliation unknown1
Rivaldi AditiantoAffiliation unknown1
Widodo KurniantoAffiliation unknown1
Alfi Sholehah Dwi MeyraniAffiliation unknown1
Rina Aenun RohmadiatiAffiliation unknown1
Dewi SetianingrumAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, first harvested 8 Nov 2026, last seen 8 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Differences in the impact of harmonic distortion due to the installation of electronic load controller in self-excited induction generator and synchronous generator</dc:title>
	<dc:creator>Nazir, Refdinal</dc:creator>
	<dc:creator>Syafii, Syafii</dc:creator>
	<dc:creator>Pawawoi, Andi</dc:creator>
	<dc:creator>Akbar, Fajril</dc:creator>
	<dc:creator>Doriza, Axel</dc:creator>
	<dc:subject xml:lang="en-US"></dc:subject>
	<dc:description xml:lang="en-US">In general, the application of Self-Excited Induction Generator (SEIG) or Synchronous Generator (SG) on the Stand-Alone Micro Hydel Power Plant (MHPP) is equipped with Electronic Load Controller (ELC) to control generator output during variations in consumer load. One type of ELC that is cheap and rigid developed today is the ELC, which is constructed by the uncontrolled bridge rectifier with DC Chopper. Based on the operational concept, basically this type of ELC can be implemented on both SEIG and SG, but both of these generators will have a different harmonic distortion effect on the output and its load. This paper examines the differences in the effects of harmonic distortions due to ELC installation on SEIG and SG. The initial stage of this study was to design the ELC developed. Then, the harmonic distortion response due to the installation of ELC on SEIG and SG is tested, which includes harmonic distortion in: stator current, PCC voltage, and consumer load current. THDI (Current Total Harmonic Distortion) stator current at SEIG with ELC has shown an average value smaller than the THD stator current in SG with ELC. Likewise, the THDV (Voltage Total Harmonic Distortion) value of PCC voltage and THDI value of the current consumer load on SEIG equipped with ELC has been shown to be smaller than the THDV value of PCC voltage and THDI value of the current consumer load on SG equipped with ELC. The effects of harmonic distortions due to the installation of ELCs that developed in this study on SEIG is still within the permitted limits, while on the SG, the harmonic distortion reduction is needed at the generator output.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2019-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/15132</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v10.i1.pp104-116</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 10, No 1: March 2019; 104-116</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v10.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/15132/10886</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2019 Refdinal Nazir, Syafii Syafii, Andi Pawawoi, Fajril Akbar, Axel Doriza</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>